Instruments and Methods: Portable Thermal Core Drill for Temperate Glaciers

R. L. Shreve, W. B. Kamb
1964 Journal of Glaciology  
In the summer of 1962 a completely portable and relatively simple electrically heated thermal core drill of new design was constructed and used to obtain 16 oriented samples of ice 2.5 cm. in diameter by 120 cm. in length from depths ranging from 12 m. to 137 m. in lower Blue Glacier, Mount Olympus, Washington, U.S.A. The thermal element is a 0.260-in. (0.66-cm.) diameter 300-W. 150-V. tubular heater bent to form an annulus with an external diameter of 5.0 cm. Opposed ratchet-like teeth break
more » ... f and hold the core inside the tubular core barrel. Orientation is recorded photographically by a commercial inclinometer modified to show azimuth and to be controlled from the surface.
doi:10.3189/s002214300002863x fatcat:h33vup7wzzh4zj52ylmxwgzmuy