Study on the determination of optimum size of storage tank and intercepting capacity for CSOs reduction in urban area
도시지역 CSOs 저감을 위한 저류조 및 이송관로의 최적 용량결정에 관한 연구

Kwan Yong Lee, Won Suk Choi, Yong Jae Lee, Won Suk Koo, Chang Soo Song
2012 Journal of The Korean Society of Water and Wastewater  
Storage method is one of major measures for reduction of CSOs pollutant loads and several projects have been done nationwide. But systematic analysis of intercepting capacity has not been studied to determine optimum size of storage facility. In this research, not only storage volume but also intercepting capacity which means flow capacity from intercepting facility to CSOs storage facility was studied and optimum sizing method for storage facility was proposed. The result shows that pollutants
more » ... reduction efficiency can be increased significantly by increasing intercepting capacity and it might reduce storage volume and total construction costs. Intercepting capacity for the study area was evaluated and it was shown as equivalent to 83 % probability rainfall intensity.
doi:10.11001/jksww.2012.26.6.735 fatcat:rg3xkz2ar5abvb7gnakhqr32zi