A copy of this work was available on the public web and has been preserved in the Wayback Machine. The capture dates from 2018; you can also visit the original URL.
The file type is application/pdf
.
Evaluation of Tube Wall Thickness of Feed Water Heater
2008
Journal of Power and Energy Systems
With regard to the high pressure(HP) feed water heater of thermal power plant at Tokyo Electric Power Company(TEPCO) sites, inspection of feed water(FW) tubes wall thickness are conducted whenever required such that frequent tube leak occurs. As a standard inspection methodology, FW heater is disassembled during planned outage, tube wall thickness is measured by the ultrasonic pulse techique(UT), then plugs are installed at the both ends of FW tube if its measured wall thickness is found below
doi:10.1299/jpes.2.1096
fatcat:uswp4sbzsved5c46x2sxj4ssiy