A CMOS mixed-signal interface with a RF transmitter for a micromachined soil moisture sensor
2003 IEEE International Symposium on Industrial Electronics ( Cat. No.03TH8692)
This paper describes a CMOS mixed-signal interface with a RF transmitter. This die is assembled in a Multi-Chip-Module (MCM) micro-system together with the micromachined soil moisture sensor to achieve a cost-effective solution with accurate and reliable measurements for soil moisture in agriculture. The soil moisture probe, based on Dual-Probe Heat-Pulse (DPHP) method, is fabricated in bulkmicromachining technology. The DPHP method is based on the measurement of the maximum temperature rise at
doi:10.1109/isie.2003.1267950