An extended area blackbody for radiometric calibration
2013
Infrared Imaging Systems: Design, Analysis, Modeling, and Testing XXIV
SBIR is developing an enhanced blackbody for improved radiometric testing. The main feature of the blackbody is an improved coating with higher emissivity than the standard coating used. Comparative measurements of the standard and improved coatings are reported, including reflectance. The coatings were also tested with infrared imagers and a broadband emissivity estimate derived from the imagery data. In addition, a control algorithm for constant slew rate has been implemented, primarily for
doi:10.1117/12.2016251
fatcat:llrs7de725dn5fburgdrz3zlcq