The Effect of Gap Angle on Tensile Strength of Preceramic Base Metal Solder Joints
2015
Dent Shiraz Univ Med Sci
unpublished
Statement of the Problem: Soldering is a process commonly used in fabricating dental prosthesis. Since most soldered prosthesis fail at the solder joints; the joint strength is of utmost importance. Purpose: The purpose of this study was to evaluate the effect of gap angle on the tensile strength of base metal solder joints. Materials and Method: A total number of 40 Ni-Cr samples were fabricated according to ADA/ISO 9693 specifications for tensile test. Samples were cut at the midpoint of the