Restoring the Skew Quadrupole Moment in Tevatron Dipoles
Proceedings of the 2005 Particle Accelerator Conference
In early 2003 it was realized that mechanical changes in the Tevatron dipoles had led to a deterioration of the magnetic field quality that was hindering operation of the accelerator. After extensive study, a remediation program was started in late 2003 that will continue through 2005. The mechanical and magnetic effects are discussed. The readjustment process and experience are reported, along with other observations on aging magnets.
doi:10.1109/pac.2005.1591427