Improvements of NSLS-II X-ray Diagnostic Beamlines

Weixing Cheng, Belkacem Bacha, Bernard Kosciuk, Danny Padrazo Jr, Schaa, Volker RW (Ed.), Satogata, Todd (Ed.)
2018
There are two X-ray diagnostic beamlines (XDB) developed at NSLS-II storage ring to measure emittance, energy spread, and other machine parameters. The first beamline utilizes a soft bending magnet radiation has been in operation since 2014. The tungsten pinhole originally located in the air had corrosion issue. The beamline has been improved by extending the vacuum to the imaging system. The second X-ray pinhole beamline using three-pole wiggler (TPW) radiation has been constructed and
more » ... tructed and commissioned recently. Energy spread is able to be precisely measured due to large dispersion at the source point. A gated camera is equipped with the new beamline to acquire profiles within one turn. Recent operation experience and beam measurements will be presented in this paper.
doi:10.18429/jacow-ipac2018-wepaf012 fatcat:fwfz4qhakneezobbfybvjarhhy