The Quaternary groundwater as the low temperature energy source for heat pumps in Małopolska Province

Ewa Kmiecik, Barbara Tomaszewska, Justyna Mazurkiewicz, B. Kaźmierczak, M. Kutyłowska, K. Piekarska, H. Jouhara, J. Danielewicz
2017 E3S Web of Conferences  
The paper presents the assessment of using Quaternary groundwater as the low-temperature energy source for heat pumps in the Małopolska Province. The analysis demonstrates that the Małopolska region has potential to use Quaternary groundwater in low-temperature systems both in terms of potential well flow rates and water temperature. Water as a heat source must also meet the relevant requirements in terms of the physical and chemical parameters indicated by manufacturers of heat pumps as
more » ... eat pumps as important for the proper operation of installations.
doi:10.1051/e3sconf/20172200082 fatcat:t2bnm5fb2vcsroc7nsqngggb7i