Hardware in the loop simulation test platform of fuel cell backup system

Tiancai Ma, Fuxian Wang, Shi Xu, Dong Zhu, Yuanxing Dai, Rongxin Gu, P. Tandon, M. Guo
2015 MATEC Web of Conferences  
Based on an analysis of voltage mechanistic model, a real-time simulation model of the proton exchange membrane (PEM) fuel cell backup system is developed, and verified by the measurable experiment data. The method of online parameters identification for the model is also improved. Based on the software LabVIEW/VeriStand real-time environment and the PXI Express hardware system, the PEM fuel cell system controller hardware in the loop (HIL) simulation plat-form is established. Controller
more » ... . Controller simulation test results showed the accuracy of HIL simulation platform. 7 This is an Open Access article distributed under the terms of the Creative Commons Attribution License 4.0, which permits distribution, and reproduction in any medium, provided the original work is properly cited. XQUHVWULFWHG XVH Article available at