124 Delayed-enhancement MRI as a predictor of functional recovery after revascularization: results from an International Multicenter Viability Trial

Veronica V Lenge, Raja Muthupillai, Harrie Bosch, John Greenwood, Rungroj Krittyaphong, Wong Kim, Reza Razavi, Peter Danias, Eike Nagel, Scott D Flamm
2008 Journal of Cardiovascular Magnetic Resonance  
Purpose Several single center studies have shown that Delayedenhancement (MRI DE-MRI) can predict functional recovery after revascularization [1, 2] . The purpose of this study was to determine the prognostic value of DE-MRI for predicting recovery of regional wall motion abnormality after revascularization in patients with chronic coronary artery disease (CAD) in a prospective, international, multicenter trial. Methods 183 patients (167 men, age: 59.1 ± 9.7 years) with angiographically
more » ... graphically confirmed CAD and resting wall motion abnormality (WMA) scheduled for coronary bypass (n = 101) or angioplasty (n = 82) were enrolled from 9 institutions (US, Europe, and Asia) using a standardized imaging protocol. Functional and DE-MRI were performed within 30 days prior to and 5.6 ± 2.4 months after intervention. Data Acquisition All images were acquired on a Philips 1.5 T imager with VCG gating, and a five-element synergy cardiac coil was used for signal reception. A steady-state free precession (SSFP) sequence was used for cardiac cine imaging: TR/ TE/flip: 2.7 msec/1.3 msec/65°; FOV: 320 mm, matrix: 160 × 160, slice thickness: 10 mm; slice gap: 0 mm; acquired voxel size: 2.0 × 2.0 × 10.0 mm and reconstructed voxel size: 1.3 × 1.3 × 10.0 mm; temporal resolution: 25-40 msec depending on heart rate. Cine SSFP images were acquired in the two long -axis orientations (vertical long axis and 4 chambers) and short axis orientations (10 to 12 contiguous short-axis cine SSFP images from mitral valve plane through the apex). DE-MRI images were acquired 15 minutes after administering 0.2 mmol/kg of gadolinium-chelate (OptiMARK™) in the same orientation as the cine images. The DE-MRI sequence was an inversion-recovery prepared, segmented gradient echo acquisition with the following acquisition parameters: field-of-view: 384 × 384 mm; matrix size: 256 × 256; acquired voxel size: 1.5 × 1.5 × 10 mm; 32 phase encoding steps per RR interval; TR/TE/flip: 4.6/1.9/15°; NSA: 2; acquisition time per slice: 16 RR intervals. The inversion delay time (TI) between the inversion pulse and the beginning of the data acquisition necessary to null the signal from normal myocardium was determined by the Look-Locker sequence. The data acquisition was timed to occur in diastole to minimize cardiac motion. from
doi:10.1186/1532-429x-10-s1-a25 fatcat:zsk4pgbgcfazbanhw7lnnjbc2u