Clinical Analysis of Inverse Planning for Radiosurgery ; Gamma Knife Treatment Plan Study
방사선 수술 역방향 치료계획 유용성 평가

Seong Jin Jin, Jae Yong Je, Cheol Woo Park
2015 Journal of the Korean Society of Radiology  
The purpose of this study is a comparison of forward planning(FP) and inverse planning(IP) of a radiosurgery procedure. 10 patients of acoustic schwannoma MR image were used for treatment plan. FP-1,2 and IP were established under the same condition. FP and IP were compared by number of shot, conformity index(CI), paddic conformity index(PCI), gradiant index(GI) and treatment time. On average the treatment plan produced by IP tool provided an improved or similar CI, PCI, GI and reduced
more » ... nd reduced treatment time as compared to the FP (CI;FP-1:0.85, FP-2:0.86, IP:0.94, PCI;FP-1:0.79, FP-2:0.81, IP:0.78, GI;FP-1:2.94, FP-2:2.94, IP:3.01). The inverse planning system provides a clinically useful plan while reducing the planning time and treatment time. 요 약 감마나이프 방사선수술 전방향 치료계획과 역방향 치료계획을 비교 분석하였다. 10 case의 청신경초종 영상을 이용 하여 동일한 조건으로 전방향 치료계획 1, 2(FP-1,2) 및 역방향 치료계획(IP)을 수립하고, 샷의 수(No of shot), conformity index(CI), Paddic conformity index(PCI), Gradiant index(GI), 치료시간 등을 비교 하였다. IP가 FP에 비 하여 샷의 수가 적었으며, 표적용적이 증가할수록 샷의 수는 증가하였다. CI는 FP-1:0.85, FP-2 :0.86, IP:0.94, PCI 는 FP-1:0.79, FP-2 :0.81, IP:0.78로 IP가 높거나 비슷한 결과를 보였다. GI는 FP-1:2.94, FP-2:2.94, IP:3.01로 비슷한 값을 나타내었다. FP를 기준으로 상대적 조사시간은 전체적으로 IP가 짧은 것으로 나타났다. IP는 FP와 비슷 하거나 우수한 평가값을 나타내고 치료계획에 소요되는 시간이 짧고 치료시간이 짧아 임상적으로 유용한 것으로 판단 된다. 중심단어: 방사선 수술, 감마나이프, 전방향 치료계획, 역방향 치료계획. http://dx.Addr. Dong-Eui institute of technology.
doi:10.7742/jksr.2015.9.6.343 fatcat:cqrrck5625fmlpvadwlto35c7y