The Main Injector trim dipole magnets

R. Baiod, D.J. Harding, D.E. Johnson, P.S. Martin, S. Mishra
Proceedings Particle Accelerator Conference  
To correct field and alignment errors, provide full aperture steering at injection, and control the horizontal orbit in the straight section, a 0.060 T-m and a 0.090 T-m correctors were designed. The two magnets were chosen to have identical lamination cross section and identical coil packages, however the normal low field corrector has no cooling while a water cooled plate is incorporated to the high field one. Diffusion of the heat through the copper conductor, insulations, and magnet steel,
more » ... ith and without plate cooling, was analyzed, and temperatures were estimated. We report in this presentation the calculations of the various magnet parameters, and in particular, the procedure to optimize the temperature of the steel and the temperature of the inner copper coil.
doi:10.1109/pac.1995.505212 fatcat:q36ka73w5rahborajny64isohm