A copy of this work was available on the public web and has been preserved in the Wayback Machine. The capture dates from 2019; you can also visit the original URL.
The file type is application/pdf
.
An Experimental Determination of a Swing Check Valve Closure Time in the Main Feed Water System of a Power Plant during Shut-down Process
발전소 주급수 계통 감발 과정에서의 스윙체크밸브 닫힘 시점의 실험적 결정
2009
Transactions of the Korean Society for Noise and Vibration Engineering
발전소 주급수 계통 감발 과정에서의 스윙체크밸브 닫힘 시점의 실험적 결정
The reliable operation of a swing check valve in the main feed water system of a power plant is most essential for successful shout-down process. A failure to close the valve at proper time often leads to the instability of the main feed water system, or even to an emergency stop of the power plant. In reality it is a very difficult task to monitor the behavior of a swing check valve. Furthermore it is impossible to see the motion of the valve. In this work two measurements were carried out simultaneously to determine
doi:10.5050/ksnvn.2009.19.8.843
fatcat:gvusrlmt3jedvcbzpr2ai4xrgy