RP-HPLC method development and validation for estimation of rivaroxaban in pharmaceutical dosage forms

Mustafa Çelebier, Tuba Reçber, Engin Koçak, Sacide Altinöz
2013 Brazilian Journal of Pharmaceutical Sciences  
Rivaroxaban, an anti-clotting medication, acts at a crucial point in the blood-clotting process and stops the formation of blood clots. In this study, RP-HPLC method was developed for the determination of rivaroxaban in tablets (Xarelto® (10 mg)). Phenomenex Luna 5 µm C18 100 Å LC Column (250 x 4.6 mm) was used at 40 ºC. Isocratic elution was performed with ACN:Water (55:45 v/v) mixture. The flow rate was 1.2 mL min-1 and UV detection was at 249 nm. Internal standard (Caffeine) and rivaroxaban
more » ... ere eluted within 2.21 and 3.37 minutes, respectively. The developed method was validated according to the ICH guidelines and found to be linear within the range 0.005 - 40.0 µg mL-1. The method was accurate, precise, robust and rapid. Thus, it was applied successfully for the quality control assay of rivaroxaban in tablet dosage form.
doi:10.1590/s1984-82502013000200018 fatcat:gonoe2fvsnar3mp663b3ezs264