INVESTIGATION INTO THE RATE OF TRIOCTYLAMINE PARTITIONING INTO THE MCU AQUEOUS PHASES [report]

T. Peters, A. Couture
2013 unpublished
The Savannah River National Laboratory (SRNL) has examined the issue of trioctylamine (TOA) losses at the Modular Caustic-Side Solvent Extraction Unit (MCU) solvent. For this study, SRNL used partitioning and radiolysis data from the Oak Ridge National Laboratory (ORNL) as well as actual MCU operational data. From the radiolysis data, SRNL prepared a model on the rate of TOA degradation. From the combined sets of data, SRNL has calculated the largest possible value of TOA (although this value
more » ... though this value is not credible) in the Strip Effluent (SE) and also calculated two different conservative, more realistic values for TOA in the SE. Even under conservative assumptions, such as all of the TOA losses partitioning solely into the Strip Effluent (SE), the MCU operational data suggests that the maximum realistic TOA concentration in the SE is < 0.6 mg/L.
doi:10.2172/1089290 fatcat:frsy7pc4nbczlil25erldbwkv4