A copy of this work was available on the public web and has been preserved in the Wayback Machine. The capture dates from 2017; you can also visit the original URL.
The file type is application/pdf
.
High Voltage Transformer Design using Self-Resonant Characteristics of Transformer
트랜스포머의 자가공진 특성을 이용한 고전압 트랜스포머 설계
2014
Journal of IKEEE
트랜스포머의 자가공진 특성을 이용한 고전압 트랜스포머 설계
In this paper, self-resonant characteristics of transformers were analyzed in accordance with changes of characteristics regarding to the stray capacitance, the volume of winding and the winding ratio were organized by formulas. Generally, the stray capacitance is considered as an unnecessary factor in processing transformers design as well as one of the inherent characteristics. In particular, these characteristics can be appeared clearly in the high frequency driving and Electrical resonance
doi:10.7471/ikeee.2014.18.1.031
fatcat:klvkxqyvhnfu7jycswfg5tdpvi