Pumping power station ash as a high concentration slurry
2010
Proceedings of the Thirteenth International Seminar on Paste and Thickened Tailings
unpublished
Determining the pumping characteristics of a full scale power station ash disposal system is fraught with difficulties. This paper examines the pumping characterises of high concentration slurry comprising of a mixture of a power station ash and process water as determined using a rotary viscometer and small scale pumping test rig.
doi:10.36487/acg_rep/1063_46_bunn
fatcat:qcc7hfbldrfu3i4pgpgeb4pplu