Development of a Novel Compact Tension Specimen to Mitigate Premature Compression and Buckling Failure Modes within Fibre Hybrid Epoxy Composites

T.J. Katafiasz, L. Iannucci, E.S. Greenhalgh
2018 Composite structures  
A Notched Curved Compact Tension (NCCT) and Extended Notched Curved Compact Tension (ENCCT) specimen geometries are presented for the measurement of translaminar critical strain energy release rates in composite laminates with low compressive to tensile strengths. Premature compressive and buckling failure occurred when a conventional Compact Tension (CT) specimen geometry (similar to ASTM E399 (2013)) was utilised for monolithic Non-Crimp Fabric (NCF) S2-Glass/MTM57 epoxy composite and an
more » ... layer fibre hybrid T700 carbon spread tow/NCF S2-glass epoxy composite. The NCCT and ENCCT specimen design methodology and manufacturing routes are presented where premature compressive failure was mitigated through a curvature at the rear of the profile and the introduction of a through-thickness groove that had been pre-cured along the crack growth region. The latter ensured that buckling was eliminated, whilst stable crack growth was achieved. The development involved FE model material validation and optimisation for the novel specimen design. Experimental tests presented both interlayer and intralayer fibre hybrid composites with good repeatability and low scatter within the results.
doi:10.1016/j.compstruct.2018.06.124 fatcat:k6clnldwmzecxn3lu7x5lnzjz4