Filters








169,596 Hits in 2.1 sec

The Need of Analytical Techniques for In-Situ Study of Soil Organic Matter

Meena BL
2016 Advances in Plants & Agriculture Research  
and Magic angle spinning) has emerged as most reliable analytical technique.  ...  techniques for in-situ study of soil organic matter Volume 4 Issue 4 -2016 Meena BL, Meena RL, Kaledhonkar MJ Project Coordinating Unit, ICAR-Central Soil Salinity Research Institute, India Correspondence  ... 
doi:10.15406/apar.2016.04.00146 fatcat:nfkmyzii3fdlhmbdnfjsrz4oru

Assessing the veracity of Precambrian 'sponge' fossils using in situ nanoscale analytical techniques

A.D. Muscente, F. Marc Michel, James G. Dale, Shuhai Xiao
2015 Precambrian Research  
In order to assess their veracity as the oldest spiculate demosponges, we utilize a suite of in situ nanoscale analytical techniques-including scanning electron microscopy, synchrotron Xray fluorescence  ...  These results indicate that interpretations of Precambrian sponge fossils should be scrutinized with compositional, mineralogical, and ultrastructural data collected using in situ analytical techniques  ...  Future studies should test of the veracity of these fossils using in situ Muscente et al. 20 analytical techniques and cogent evaluation criteria.  ... 
doi:10.1016/j.precamres.2015.03.010 fatcat:rsjbllg2evhc3d6qoldxpcossm

A Simple Colorimetric Analytical Assay for the Determination of Tetracyclines based on In-situ Generation of Gold Nanoparticles Coupling with a Gold Staining Technique

Ningning YUE, Dongmei LI, Aiping FAN
2021 Analytical Sciences  
Sensitive detection of TCs was achieved by employing the gold staining technique.  ...  The present study developed a colorimetric method for the detection of TCs based on the in-situ generation of AuNPs which is subsequently coupled with a gold staining reaction.  ...  S6) , comparison of the analytical performance of this colorimetric method with other methods (Table S1) and recovery of OTC spiked in milk samples (Table S2 ).  ... 
doi:10.2116/analsci.21p115 pmid:33994417 fatcat:36onqej33zde3pw6rtp3fe2isq

A Review of In Situ Isotopic Studies of the Oklo and Bangombé Natural Fission Reactors Using Microbeam Analytical Techniques

Hiroshi Hidaka
2020 Minerals  
In the past two decades, microbeam techniques using ion and laser probe facilities have been effectively applied for the in situ isotopic analyses of individual microminerals to investigate the migration  ...  As conventional analytical techniques before 2000 were based on bulk analysis, the situation of heterogeneous distribution of fissiogenic products in and around natural reactors remained unclear.  ...  (c) Back-scattered-electron (BSE) image of a part of the thin section sample (b). 10 to 20 m-sized craters in the photo (c) are in situ analytical spots by SHRIMP.  ... 
doi:10.3390/min10121060 fatcat:bibtdlaccjcotbxerfx4dz53xq

Localized in Situ Hydrogel-Mediated Protein Digestion and Extraction Technique for on-Tissue Analysis

Glenn A. Harris, Joshua J. Nicklay, Richard M. Caprioli
2013 Analytical Chemistry  
A simultaneous on-tissue proteolytic digestion and extraction method is described for the in-situ analysis of proteins from spatially distinct areas of a tissue section.  ...  This technology provides a versatile workflow that can be used to correlate multiple complementary analytical approaches in the analysis of a single tissue section.  ...  Described here is a spatially-directed simultaneous on-tissue proteolytic digestion and extraction technique to be used in conjunction with existing MALDI IMS workflows.  ... 
doi:10.1021/ac3031493 pmid:23402265 pmcid:PMC3595595 fatcat:wgq4cj67o5arhnqxtuhu7ckgb4

Studies of ferroelectric heterostructure thin films and interfaces, via in situ analytical techniques

Orlando Auciello, Alan R. Krauss, Jaemo Im, Anil Dhote, Dieter M. Gruen, Eugene A. Irene, Ying Gao, Alex H. Mueller, Ramamoorthy Ramesh
2000 Integrated Ferroelectrics  
IN SITU STUDIES OF FERROELECTRIC FILMS AND DEVICEPROCESS CONCLUSIONS We have demonstrated that in situ and/or in situ, real-time characterization techniques can provide a wide range of information on  ...  In addition, we have demonstrated that an appropriate combination of in situ or in situ, real-time characterization techniques can provide valuable information to aid in the understanding of polarization  ... 
doi:10.1080/10584580008222216 fatcat:xxjmwbiq2fhmtk7mxqjjomfal4

In Situ Quantification of Glucose Concentration in Airway Surface Liquid With Functionalized ZnO Nanorod-Coated Microelectrodes

Alejandro A Pezzulo
2013 Journal of Analytical & Bioanalytical Techniques  
Growth and characterization of ZnO nanostructures ZnO nanostructures were grown using the low-temperature growth technique (aqueous chemical growth technique) on Ag coated tips of borosilicate glass capillaries  ...  These results demonstrate the capability to perform biologically relevant measurements of glucose in ASL in situ.  ... 
doi:10.4172/2155-9872.s7-002 pmid:23227447 pmcid:PMC3514975 fatcat:prznly557zd6jfggullgdsad74

Determination of Mercury in Biological Tissues by Graphite-furnace Atomic Absorption Spectrometry with an in-situ Concentration Technique

Li-li YANG, De-qiang ZHANG, Qiu-xiang ZHOU
2002 Analytical Sciences  
A method has been described for the determination of total mercury by graphite-furnace atomic absorption spectrometry (GFAAS) using an in-situ concentration technique with a Pd-Zr coating and a chemical  ...  The purpose of the present work is to propose a method for the determination of total mercury by GFAAS using an in-situ concentration technique.  ...  [5] [6] [7] However, there are two disadvantages with this amalgamation technique, as reported by some authors.  ... 
doi:10.2116/analsci.18.811 pmid:12137378 fatcat:tjzraulxzra3thpu3o2zqcnv5e

Special Issues/In Situ Surface Analytical Techniques and Their Applications to Surface Finishing Technology. In Situ Ellipsometry in Analysis of CVD Process
特集/表面技術とその場測定 CVDプロセスのIn Situエリプソメトリー

Katsuhisa SUGIMOTO
1992 Journal of The Surface Finishing Society of Japan  
doi:10.4139/sfj.43.424 fatcat:d2cuv6xn4featlj7i35hea3usq

In Situ Evaluation of Physiological Activity and Mitochondrial Dysfunction via Novo Label-Free Measures Based on Fluctuation of Image Gray Values

2016 Journal of Analytical & Bioanalytical Techniques  
wherein cells are individually held untethered, each within a picoliter volume optical chamber in an array, which allows repeatable spatiotemporal observation before, during and after bio-manipulation in situ  ...  That is the most common and relatively simple technique for monitoring mitochondrial function in intact cells at single-cell level.  ... 
doi:10.4172/2155-9872.1000308 fatcat:tt5sokdh6bgipmyiyrxjizrize

In Situ Primary Production Measurements as an Analytical Support to Remote Sensing - An Experimental Approach to Standardize the 14C Incorporation Technique [chapter]

Tamara Cibic, Damiano Virgilio
2011 Biomass and Remote Sensing of Biomass  
www.intechopen.com In Situ Primary Production Measurements as an Analytical Support to Remote Sensing -An Experimental Approach to Standardize the 14 C Incorporation Technique 259 Fig. 6 .  ...  www.intechopen.com In Situ Primary Production Measurements as an Analytical Support Table 4 .  ...  In Situ Primary Production Measurements as an Analytical Support to Remote Sensing -An Experimental Approach to Standardize the 14C Incorporation Technique, Biomass and Remote Sensing of Biomass, Dr.  ... 
doi:10.5772/17175 fatcat:vltt7lk5bbd4fndmlg2zxahogi

Non-Destructive Portable Analytical Techniques for Carbon In-Situ Screening Before Sampling for Dating Prehistoric Rock Paintings

Lucile Beck
2013 Radiocarbon: An International Journal of Cosmogenic Isotope Research  
Thus, it is very important to check the presence of organic carbon-based material in situ before sampling in order to protect the visual integrity of the paintings or drawings.  ...  These techniques have been chosen for their non-destructiveness: no sample has to be taken from the rock surface and no contact is made between the probes and the paintings or drawings.  ...  In conclusion, thanks to the development of new portable and non-destructive analytical instruments, it is now possible to select suitable samples for 14 C dating in situ in the cave.  ... 
doi:10.2458/azu_js_rc.55.16248 fatcat:ex5mywzbzbbotgsaqx2zhvhdf4

On-line analysis and in situ pH monitoring of mixed acid fermentation by Escherichia coli using combined FTIR and Raman techniques

George D. Metcalfe, Thomas W. Smith, Michael Hippler
2020 Analytical and Bioanalytical Chemistry  
The analytical range extends to at least 1 M with a standard deviation of percentage error of about 8%.  ...  The measurement of the anions of the phosphate buffer allows the spectroscopic, in situ determination of the pH of the bacterial suspension via a modified Henderson-Hasselbalch equation in the 6-8 pH range  ...  Spectroscopic techniques are powerful analytical tools which allow for rapid, selective, and on-line measurements.  ... 
doi:10.1007/s00216-020-02865-5 pmid:32794006 fatcat:5h3gshfztzcddjjg6t7dbdyqem

Studies of ferroelectric heterostructure thin films, interfaces, and device-related processes via in situ analytical techniques

Orlando Auciello, Alan R. Krauss, Jaemo Im, Anil Dhote, Dieter M. Gruen, Sanjeev Aggarwal, Ramamoorthy Ramesh, Eugene A. Irene, Ying Gao, Alex H. Mueller
1999 Integrated Ferroelectrics  
Conventional analytical techniques have not been able to clearly describe the state of the Pt surface tier heating, or explain how the Pt surface condition (on the monolayer scale) affects the growth of  ...  In addition, we have demonstrated that an appropriate combination of in situ or in situ, real-time characterization techniques can provide valuable information to aid in the understanding of polarization  ... 
doi:10.1080/10584589908228460 fatcat:6pvqjmbn4fbm5npzrwgf7b7gau

An in situ technique for (U–Th–Sm)/He and U–Pb double dating

N. J. Evans, B. I. A. McInnes, B. McDonald, M. Danišík, T. Becker, P. Vermeesch, M. Shelley, E. Marillo-Sialer, D. B. Patterson
2015 Journal of Analytical Atomic Spectrometry  
New in situ (U–Th–Sm)/He and U–Pb zircon double dating method replicates results obtained using conventional methods at the Ellendale diamond occurrence.  ...  Solution U, Th and Sm analysis for conventional (U-Th-Sm)/He dating was performed at TSW Analytical, Perth.  ...  Conclusions We have demonstrated a new and effective analytical system for in situ U-Pb and (U-Th-Sm)/He double dating of zircon.  ... 
doi:10.1039/c5ja00085h fatcat:2jkn4lzj6ngglk22psck4t6oeq
« Previous Showing results 1 — 15 out of 169,596 results