Uncertainty reducing method for the reference standards in gauge block comparator calibration
2014
Measurement (London)
A simple method for reducing the uncertainty of reference standards has been proposed for gauge block comparator calibration. Errors due to the reference value of the length difference for mechanical comparator evaluation can be reduced by using the average of two reference values. Two reference values of length difference are obtained by the appropriate combination of three gauge blocks. Errors caused by reference gauges are canceled and averaged. An error reduction effect was successfully demonstrated using an actual mechanical comparator.
doi:10.1016/j.measurement.2014.01.001
fatcat:dvgf2xgkkjgjbp6mozn36v3nqi
Round robin comparison study on the form measurement of optical freeform surfaces
2020
Journal of the European Optical Society-Rapid Publications
A round robin comparison of freeform form measurements was carried out by the project partners and stakeholders of a European metrology research project. Altogether six measuring instruments were considered: five different (pointwise and areal) optical devices and one tactile device. Three optical freeform surfaces were used for the comparison measurements, where two specimens were measured by five instruments and one specimen by four instruments. In this paper, the evaluation methods and
doi:10.1186/s41476-019-0124-1
fatcat:qpuwzy6tdnddpohldcb26uclyu
more »
... s of this round robin are presented for the three freeform surfaces made from a temperature-stable material, Super Invar ® . The freeforms had diameters of 40 mm, 50 mm and 100 mm and best-fit radii of 39.75 mm (convex), 40.9 mm (convex) and 423.5 mm (concave). For comparison, the bilateral pointwise differences between the available measurements were calculated. The root-mean-square values of these differences ranged from 15 nm to 110 nm (neglecting spherical contributions) and provided an insight into the status of typical freeform measurement capabilities for optical surfaces.
Gauge block interferometer using three frequency-stabilized lasers
3本の安定化レーザを用いた長尺ブロックゲージ干渉計の開発
2002
Journal of the Japan Society for Precision Engineering
3本の安定化レーザを用いた長尺ブロックゲージ干渉計の開発
Bitou, A. Onae, J. Yoda, H. ...
大苗 敦***岩 崎 茂 雄***瀬 田勝 男***
Gauge block interferometer using three frequency-stabilized lasers
Youichi ...
doi:10.2493/jjspe.68.542
fatcat:iyclcdy2b5bjfppcfo3l34jk4e
Precision Length Metrology Based on the Time and Frequency Standards Using Optical Combs
光コムを用いた時間・周波数標準に基づく精密長さ計測
2007
The Review of Laser Engineering
光コムを用いた時間・周波数標準に基づく精密長さ計測
Traceable Reference Full Metrology Chain for Innovative Aspheric and Freeform Optical Surfaces Accurate at the Nanometer Level
2021
Sensors
The design of innovative reference aspheric and freeform optical elements was investigated with the aim of calibration and verification of ultra-high accurate measurement systems. The verification is dedicated to form error analysis of aspherical and freeform optical surfaces based on minimum zone fitting. Two thermo-invariant material measures were designed, manufactured using a magnetorheological finishing process and selected for the evaluation of a number of ultra-high-precision measurement
doi:10.3390/s21041103
pmid:33562598
pmcid:PMC7915810
fatcat:tjmu7gk65zdfrfe2mq6e4yueoe
more »
... machines. All collected data sets were analysed using the implemented robust reference minimum zone (Hybrid Trust Region) fitting algorithm to extract the values of form error. Agreement among the results of several partners was observed, which demonstrates the establishment of a traceable reference full metrology chain for aspherical and freeform optical surfaces with small amplitudes.
21303 Accuracy improvement of uncertainty evaluation for the gauge block comparator
21303 比較測長器のかたよりに対する不確かさ評価の高精度化手法(OS13 計測・試験における不確かさ評価と応用(1),オーガナイズドセッション)
2010
The Proceedings of Conference of Kanto Branch
21303 比較測長器のかたよりに対する不確かさ評価の高精度化手法(OS13 計測・試験における不確かさ評価と応用(1),オーガナイズドセッション)
BITOU , Kensei EHARA , National Institute ofAdvaneed Industrial Sci ¢ nce and Technology Kcy WQrds: gauge btock cemparator , uncertain り it d ∈ ガection To use a gauge block cemparator with no collection ...
ofuncertainty evaluation for the gauge block comparator ○ 正 細 谷 肇 ・ 群馬 産 技 セ ン タ ー 正 眞 下 寛治 ・ 群馬 産 技 セ ン タ ー 尾 藤 洋 一 ・ 産 総 研 榎 原 研 正 ・ 産 総 研 Hajime HOSOYA , Kanji MASHIMO , Gunma lnClustrial Technelogy Center Youichi ...
doi:10.1299/jsmekanto.2010.16.443
fatcat:2xkgj2pgdrf2ljwgjv2o3nsexi
21305 Uncertainty Evaluation Method for Flatness Using Monte Carlo Method with Pseudo Flat
21305 擬似平面を用いたモンテカルロ法による平面度の不確かさ評価法(OS13 計測・試験における不確かさ評価と応用(1),オーガナイズドセッション)
2010
The Proceedings of Conference of Kanto Branch
21305 擬似平面を用いたモンテカルロ法による平面度の不確かさ評価法(OS13 計測・試験における不確かさ評価と応用(1),オーガナイズドセッション)
参 考 文 献 ( 1) Youichi Bitou 、 Toshiyuki Takatsuji 、Kensei Ehara : Simple uncertainty evaluation method fer an intcrferomctric fiatness test fiat , Metrologi 灸 Vol . 45 , No , 1 ( 2008 ) , pp . 21 − 26 ( ...
総 研 ) 正 宮 城 善 一 ( 明 治 大 ) 榎 原 研 正 ( 産 総 研 ) Shinichi Naito , Meiji University , 1−1・ 1 Higashi−mi 臥 Tama −ku , Kawasaki − shi , Kawasaki − shi , Kanagawa 2且4 − 8571 Zenichi Miyagi , Meiji University Youichi ...
doi:10.1299/jsmekanto.2010.16.447