Filters








12,919 Hits in 5.7 sec

Visualization-Guided Evaluation of Simulated Minimally Invasive Cancer Treatment [article]

Philip Voglreiter, Michael Hofmann, Christoph Ebner, Roberto Blanco Sequeiros, Horst Rupert Portugaller, Jurgen Fütterer, Michael Moche, Markus Steinberger, Dieter Schmalstieg
2016 Eurographics Workshop on Visual Computing for Biomedicine  
We present a visualization application supporting interventional radiologists during analysis of simulated minimally invasive cancer treatment.  ...  Our system provides visual support throughout three evaluation stages, starting with determining prospective treatment success of the simulation parameterization.  ...  Introduction Over the past years, minimally invasive cancer treatment (MICT) aspired as important therapy for patients disqualifying for classical surgical removal of tumors.  ... 
doi:10.2312/vcbm.20161284 dblp:conf/vcbm/VoglreiterHESPF16 fatcat:o7k5h52v6vf2nhagx7mwlqy6yy

Front Matter: Volume 10951

Baowei Fei, Cristian A. Linte
2019 Medical Imaging 2019: Image-Guided Procedures, Robotic Interventions, and Modeling  
-34] 10951 10 10951 12 Shared visualizations and guided procedure simulation in augmented reality with Microsoft HoloLens [10951-37] 10951 13 Evaluation of 3D slicer as a medical virtual reality  ...  to guide biopsy for molecular biomarkers [10951-105] 10951 2W Electromagnetically tracked partial nephrectomy navigation: demonstration of concept [10951-106] 10951 2Y Minimally invasive intraventricular  ... 
doi:10.1117/12.2531522 fatcat:6ed6gbuiarfetfqndgjmno772a

Consensus recommendations of three-dimensional visualization for diagnosis and management of liver diseases

Chihua Fang, Jihyun An, Antonio Bruno, Xiujun Cai, Jia Fan, Jiro Fujimoto, Rita Golfieri, Xishan Hao, Hongchi Jiang, Long R. Jiao, Anand V. Kulkarni, Hauke Lang (+25 others)
2020 Hepatology International  
However, the acquisition of high-quality CT images and the use of these images for 3D visualization processing lack a unified standard, quality control system, and homogeneity, which might hinder the evaluation  ...  portal vein; meanwhile, the use of 3D models in combination with hydrodynamic analysis has become a novel non-invasive method for diagnosis and detection of portal hypertension.  ...  Guidance of digital minimally invasive surgery in the treatment of hepatolithiasis Digital minimally invasive surgery refers to the application of digital medical technology such as 3D reconstruction,  ... 
doi:10.1007/s12072-020-10052-y pmid:32638296 fatcat:khpyqbvdjjftto3p4ocl67pk5a

Precise hepatectomy in the intelligent digital era

Hao Chen, Yuchen He, Weidong Jia
2020 International Journal of Biological Sciences  
Collaborative optimization of surgery consists of three core elements, removal of lesions, organ protection and injury close monitoring, and controlled surgical intervention.  ...  In the past 20 years, the concept of surgery has undergone profound changes.  ...  Thanks to Laiyee Phoon from the Cancer Center of the Massachusetts General Hospital, Harvard Medical School for helping me to revise the text.  ... 
doi:10.7150/ijbs.39387 pmid:32015674 pmcid:PMC6990894 fatcat:4c6asj3qdfc7lm3tw5svq6lhja

A Minimally Invasive Multimodality Image-Guided (MIMIG) Molecular Imaging System for Peripheral Lung Cancer Intervention and Diagnosis [chapter]

Tiancheng He, Zhong Xue, Kelvin K. Wong, Miguel Valdivia y Alvarado, Yong Zhang, Weixin Xie, Stephen T. C. Wong
2010 Lecture Notes in Computer Science  
To tackle the common difficulties in diagnosing small lung cancer at an early stage, we developed a minimally invasive multimodality image-guided (MIMIG) interventional system for early detection and treatment  ...  of peripheral lung cancer.  ...  In the future work, we will evaluate the MIMIG system using lung cancer patient intervention experiments.  ... 
doi:10.1007/978-3-642-13711-2_10 fatcat:czxkvjo7p5fcjp2wb4qvdgkj6a

Technical Note: Multipurpose CT, ultrasound, and MRI breast phantom for use in radiotherapy and minimally invasive interventions

Mark Ruschin, Sean R. H. Davidson, William Phounsy, Tae Sun Yoo, Lee Chin, Jean-Philippe Pignol, Ananth Ravi, Claire McCann
2016 Medical Physics (Lancaster)  
Applications for the phantom include: deformable image registration (DIR) quality assurance (QA), autosegmentation validation, and localization testing and training for minimally invasive image-guided  ...  The phantoms have been evaluated for image quality and elasticity and can serve as a medium for DIR QA, autosegmentation QA, and training for minimally invasive procedures.  ...  The authors also would like to thank Samuel Richardo at the Sunnybrook Research Institute for his help in performing MRI scans of the phantom.  ... 
doi:10.1118/1.4947124 pmid:27147361 fatcat:xautc6nifbg2zj6bkohhb6o5ru

Integrated PET/CT Guidance System for Oncologic Interventional Radiology

Kenneth H. Wong, Elliot Levy, Ziv Yaniv, Filip Banovac, David Earl-Graef, Kevin Cleary
2006 2006 IEEE Nuclear Science Symposium Conference Record  
Interventional Radiology procedures such as radiofrequency ablation are a vital component of minimally invasive cancer treatment, and use of these techniques is on the rise.  ...  Finally, we have respiratory phantoms to simulate a wide variety of breathing motion and provide a robust testing platform for our system.  ...  ACKNOWLEDGMENT We thank Kass Liben, CNMT, of the Medstar Georgetown University Hospital Nuclear Medicine Service, for his technical assistance with the PET/CT system.  ... 
doi:10.1109/nssmic.2006.354344 fatcat:4h27nsy6rjhmjiyisgxchl4gtq

Computer Assistance in the Minimally Invasive Ablation Treatment of Pancreatic Cancer [chapter]

Benjamin Eigl, Andreas Andreou, Matthias Peterhans, Stefan Weber, Beat Gloor
2020 Pancreatic Cancer [Working Title]  
Minimally invasive procedures complicate the already ambitious procedure, yet the ablation method bears potential to increase the overall survival for patients with locally advanced pancreatic cancer.  ...  However, the ablation treatment is currently applied in expert centers only, which is due to the complex task of the needle placement.  ...  Matthias Peterhans is the CSO and cofounder of CAScination. Stefan Weber is CEO and cofounder of CAScination.  ... 
doi:10.5772/intechopen.93226 fatcat:n72sm3hylbfazl2ampv3glh5gq

Registration and Fusion of SPECT, High-Resolution MRI, and Interventional MRI for Thermal Ablation of Prostate Cancer

B. Fei, Z. Lee, D.T. Boll, J.L. Duerk, D.B. Sodee, J.S. Lewin, D.L. Wilson
2004 IEEE Transactions on Nuclear Science  
We are investigating interventional MRI (iMRI) guided radiofrequency thermal ablation for the minimally invasive treatment of the prostate cancer.  ...  Index Terms-Fusion visualization, image-guided minimally invasive therapy, image registration, interventional MRI, prostate cancer, SPECT.  ...  The application of SV registration methods to iMRI-guided treatment of prostate cancer raises several challenges.  ... 
doi:10.1109/tns.2003.823027 fatcat:7x4t4pcyezftjluxxvv2bdyady

The efficacy of transbronchial indocyanine green instillation for fluorescent-guided wedge resection

Yasuo Sekine, Eitetsu Koh, Hidehisa Hoshino
2021 Interactive Cardiovascular and Thoracic Surgery  
To investigate the effectiveness of ICG instillation, the clarity of the ICG-florescent border was evaluated, and the distance from the true tumour to the surgical margins was compared to that of simulation  ...  From December 2017 to July 2020, 28 patients undergoing wedge resection (17 primary lung cancers, 11 metastatic lung tumours) were enrolled, and fluorescence-guided wedge resection was attempted.  ...  Reviewer information Reviewer information Interactive CardioVascular and Thoracic Surgery thanks the anonymous reviewer(s) for their contribution to the peer review process of this article.  ... 
doi:10.1093/icvts/ivab054 pmid:33729468 pmcid:PMC8759506 fatcat:awpokbgxcfbxtjmzonx4a3rfla

Front Matter: Volume 6509

Proceedings of SPIE, Kevin R. Cleary, Michael I. Miga
2007 Medical Imaging 2007: Visualization and Image-Guided Procedures  
(USA) SESSION 3 MINIMALLY INVASIVE TECHNOLOGIES 65090D Development of continuous CT-guided minimally invasive surgery [6509-12] R. Shekhar, O.  ...  Mishra, Univ. of Pennsylvania (USA) 650905 Evaluation of different subvolume visualizations in CT-fluoroscopy guided RF liver ablation [6509-04] R. Micu, Technical Univ.  ...  65092D Real-time dynamic display of registered 4D cardiac MR and ultrasound images using a GPU (Honorable Mention Poster Award) Q. Zhang, X. Huang, Robarts Research Institute (Canada)  ... 
doi:10.1117/12.734574 dblp:conf/miigp/X07 fatcat:qnnigcuhdfb3lpb65tmvftqzwi

Focused Ultrasound Tumor Ablation in Small Animal Oncology

Max Latifi, Alayna Hay, Jennifer Carroll, Nikolaos Dervisis, Lauren Arnold, Sheryl L. Coutermarsh‐Ott, Katharine R. Kierski, Shawna Klahn, Irving C. Allen, Eli Vlaisavljevich, Joanne Tuohy
2021 Veterinary and Comparative Oncology  
Cancer treatment for solid tumors includes both treatment of the primary tumor and of metastasis.  ...  The cancer incidence rates for humans and animals remain high, and efforts to improve cancer treatment are crucial.  ...  Reports of minimally invasive pancreaticoduodenectomy and liver lobectomy in human cancer patients, and of minimally invasive adrenalectomy in dogs with cancer demonstrate the perioperative benefits of  ... 
doi:10.1111/vco.12742 pmid:34057278 fatcat:e2lez6b335crte6cmc6onw7sii

A minimally invasive multimodality image-guided (MIMIG) system for peripheral lung cancer intervention and diagnosis

Tiancheng He, Zhong Xue, Kongkuo Lu, Miguel Valdivia y Alvarado, Kelvin K. Wong, Weixin Xie, Stephen T. Wong
2012 Computerized Medical Imaging and Graphics  
Purpose: The objective of this study is to develop a Minimally Invasive Multimodality Image-Guided (MIMIG) interventional system to detect the lesion, confirm small peripheral lung cancer, and potentially  ...  guide on-the-spot treatment at an early stage.  ...  Fig. 1 . 1 The workflow of EM and image-guided diagnosis and treatment for peripheral lung cancer.  ... 
doi:10.1016/j.compmedimag.2012.03.002 pmid:22483054 fatcat:diwx3q3iszd3fem4de5ig7t2nm

Breast sentinel lymph node biopsy with imaging towards minimally invasive surgery

Fredrick Johnson Joseph, Alexander van Oepen, Michael Friebe
2017 Biomedical Engineering  
To prevent false diagnosis and achieve accurate results, minimally invasive, image-guided procedures are applied and constantly improved.  ...  A definition for an ideal imaging system combining efficient minimally invasive techniques with workflow considerations is also discussed.  ...  If the ongoing clinical studies can prove the beneficial features of image-guided SLNB, the trends of reliable, rapid diagnosis in an ambiance with faster biopsy and minimally invasive therapy would be  ... 
doi:10.1515/bmt-2016-0164 pmid:28467305 fatcat:feclvbok2vcgnml6td2buno35e

Case Report: MR-Guided Adaptive Radiotherapy, Some Room to Maneuver

Winnie Li, Jeff Winter, Jerusha Padayachee, Jennifer Dang, Vickie Kong, Peter Chung
2022 Frontiers in Oncology  
The patient reported ongoing reduction in urinary symptoms, pelvic pain, and lower limb paresthesia by the end of treatment.ConclusionUsing daily MR-guided ART, improved visualization of the changing target  ...  Treatment was planned to be delivered on the MR-Linac with a schedule of 36 Gy over 6 weekly factions allowing for maximal target dose delivery while minimizing surrounding organs at risk (OARs) radiation  ...  INTRODUCTION Image-guided radiation therapy (IGRT) enables the visualization, quantification, and correction of patient setup errors, monitoring changes to ensure high-quality dose delivery (1, 2) .  ... 
doi:10.3389/fonc.2022.877452 pmid:35494044 pmcid:PMC9047540 fatcat:cf4er43kifg5fl4zqscdp5x5xa
« Previous Showing results 1 — 15 out of 12,919 results