A copy of this work was available on the public web and has been preserved in the Wayback Machine. The capture dates from 2019; you can also visit the original URL.
The file type is application/pdf
.
Filters
Integrated Control of Hydromechanical Variable Transmissions
2015
Mathematical Problems in Engineering
A controller model is built in Matlab Simulink and cosimulated with the model of vehicle equipped with a two-range HMT. ...
The algorithm of the asymmetric saturated incremental proportional integral derivative (PID) speed control strategy in range and range shift conditions are derived. ...
With vehicle launching, accelerating, decelerating, and stopping, speed fluctuation does not happen, during range shifts or at the zero points. ...
doi:10.1155/2015/290659
fatcat:y3wjyxe7q5hpbgf3neim5dnsxu
Solar Power Tower Drives: A Comprehensive Survey
2021
IEEE Access
INDEX TERMS: renewable energy; concentrated solar power; heliostat control system; electric drives; power electronic converters. ...
The advantages and the drawbacks of the different electrical drive systems are presented and discussed. ...
Moreover, DC motors have the advantages of fast starting, acceleration, deceleration, forward, and reverse responses. ...
doi:10.1109/access.2021.3066799
fatcat:bmikurwfanaydcwyco3nfi3zme
Review and Development of Electric Motor Systems and Electric Powertrains for New Energy Vehicles
2021
Automotive Innovation
In addition, the pros and cons of different control strategies and algorithms are demonstrated. ...
AbstractThis paper presents a review on the recent research and technical progress of electric motor systems and electric powertrains for new energy vehicles. ...
figures and tables as well as partial content of this paper. ...
doi:10.1007/s42154-021-00139-z
fatcat:vy3g7otokbhqfhjzm47yrlwvie
Oral Sessions
2010
Journal of Vestibular Research-Equilibrium & Orientation
Conclusions: Vibration induced oVEMPs provide a more powerful test for discriminating between healthy subjects and patients with chronic unilateral vestibular loss than visual vertical tests during either ...
Visual vertical was measured during roll tilts between −9.6 and 9.6 • , and during rotation at 400 • /s with the head upright and the rotation axis located between ± 3.5 cm from the center of the head. ...
We thank the staff of the Center for Balance Disorders for their invaluable technical assistance. ...
doi:10.3233/ves-2010-0373
fatcat:dhpbxssuxba7ffyikf7mlbhmru
The Zwicky Transient Facility: Observing System
2020
Publications of the Astronomical Society of the Pacific
: a new 47-square-degree, 600 megapixel cryogenic CCD mosaic science camera, along with supporting equipment. ...
The OS collects and delivers digitized survey data to the ZTF Data System (DS). ...
acceleration/deceleration with up to 1°/s 2 acceleration, and 5°/s speed capability. ...
doi:10.1088/1538-3873/ab4ca2
fatcat:zn6xqf72evektmomqv5fd462di
Equal opportunity employer?
1990
Nursing Standard
For example, "The characteristics of the soils actually encountered in the subgrade may affect the quality of the cement and depth of treatment necessary." 101.02 Abbreviations. ...
These Construction and Material Specifications are written to the Bidder before award of the Contract and to the Contractor after award of the Contract. ...
, acceleration/ deceleration lanes, and ramp lanes. ...
doi:10.7748/ns.5.11.42.s51
fatcat:c6wphqvxojdkjg6usy7qcxxwf4
The Jovian Auroral Distributions Experiment (JADE) on the Juno Mission to Jupiter
2013
Space Science Reviews
JADE-I measures ions from ∼5 eV to ∼50 keV over an instanta-D.J. ...
Vault and provides all necessary control, low and high voltages, and computing support for the four sensors. ...
Acknowledgements We are deeply indebted to all of the outstanding members of the JADE team who ...
doi:10.1007/s11214-013-9990-9
fatcat:cp4otrbdlbhqdfczed7iqjzy7i
The Jovian Auroral Distributions Experiment (JADE) on the Juno Mission to Jupiter
[chapter]
2013
The Juno Mission
JADE-I measures ions from ∼5 eV to ∼50 keV over an instanta-D.J. ...
Vault and provides all necessary control, low and high voltages, and computing support for the four sensors. ...
Acknowledgements We are deeply indebted to all of the outstanding members of the JADE team who ...
doi:10.1007/978-94-024-1560-5_13
fatcat:xixhhsfutjbjdhd5x6oliwy7my
Morphed vertical tailplane assessment for certification requirements
2015
Zenodo
The results, opinions, conclusions, etc. presented in this work are those of the author(s) only and do not necessarily represent the position of the JU; the JU is not responsible for any use made of the ...
Its ground plane consists of a flexible belt that moves at wind speeds upto 40 m/s. ...
The flight paths for the LTO cycle are based on conventional take-off and landing procedures (e.g. acceleration/decelerate, climb/descent angle). ...
doi:10.5281/zenodo.3905083
fatcat:jegirrd5jbgeho7qtr7o3sfzpi
Nonlinear waves in metamaterials: state of the art
2011
Metamaterials: Fundamentals and Applications IV
The trapped sensor particle in the standing wave field axially moves to follow the measured surface topography. ...
Liberated electrons are accelerated / decelerated in the local field at the surface and affected in their attosecond dynamics by the build-up of a surface trapping potential and electron-electron interactions ...
Integration of electronics into textile, referred as e-textile, offers an opportunity of future electronics. Here, copper (Cu) and copper oxide (CuO) based nanostructures are embedded for e-textile. ...
doi:10.1117/12.892463
fatcat:fv5gdkxgn5cztc5w65zzgkbt3e
Cassini plasma spectrometer investigation
1996
Cassini/Huygens: A Mission to the Saturnian Systems
The IBS measures ion velocity distributions with very high angular and energy resolution from 1 eV to 49,800 keV. It is specially designed ...
In so doing the CAPS investigation will contribute to understanding Saturn's magnetosphere and its complex interactions with Titan, the icy satellites and rings, Saturn's ionosphere and aurora, and the ...
Acknowledgments Initial development of the CAPS instrument began in 1989. ...
doi:10.1117/12.253412
fatcat:mdlvr56xwrdsrad2ijn4duk2wi
Cassini Plasma Spectrometer Investigation
2004
Space Science Reviews
The IBS measures ion velocity distributions with very high angular and energy resolution from 1 eV to 49,800 keV. It is specially designed ...
In so doing the CAPS investigation will contribute to understanding Saturn's magnetosphere and its complex interactions with Titan, the icy satellites and rings, Saturn's ionosphere and aurora, and the ...
Acknowledgments Initial development of the CAPS instrument began in 1989. ...
doi:10.1007/s11214-004-1406-4
fatcat:oqrdete5ubb5jjaiwkb4jzjsxq
Cassini Plasma Spectrometer Investigation
[chapter]
2013
Measurement Techniques in Space Plasmas: Particles
The IMS is designed to measure the composition of hot, diffuse magnetospheric plasmas and low-concentration ion species 1 eV to 50,280 eV with an atomic resolution M/ M ∼70 and, for certain molecules, ...
The IBS measures ion velocity distributions with very high angular and energy resolution from 1 eV to 49,800 keV. ...
Acknowledgments Initial development of the CAPS instrument began in 1989. ...
doi:10.1029/gm102p0237
fatcat:c5shjyobvfhbzlf7ys4pyxe2yy
Introduction to Semi-discrete Calculus
[article]
2022
arXiv
pre-print
The Infinitesimal Calculus explores mainly two measurements: the instantaneous rates of change and the accumulation of quantities. ...
While it seems to be a special case of the rate (via the derivative sign), this work proposes a separate and favorable mathematical framework for the trend, called Semi-discrete Calculus. ...
wind turbine tower vibration control method. ...
arXiv:1012.5751v8
fatcat:jmezjckexbhordebtjyl6r3w4y
Concept, modeling and experimental characterization of the modulated friction inertial drive (MFID) locomotion principle:application to mobile microrobots
2008
It can be clearly seen that the slider is accelerated (decelerated) when the velocity of the base is larger (smaller) than that of the slider. ...
The axial vibration amplitude appears to be the most interesting parameter to use for velocity control of the MFID actuator as the velocity decreases with good linearity with decreasing axial vibration ...
correction for the weight of the mirror glued on the vibrating mass (comb drive prototype) ...
doi:10.5075/epfl-thesis-4108
fatcat:kulggnzv3rax7c7rnojtoaupn4
« Previous
Showing results 1 — 15 out of 27 results