A copy of this work was available on the public web and has been preserved in the Wayback Machine. The capture dates from 2021; you can also visit the original URL.
The file type is application/pdf
.
Filters
Toward Automatic Interpretation of 3D Plots
[article]
2021
arXiv
pre-print
This paper explores the challenge of teaching a machine how to reverse-engineer the grid-marked surfaces used to represent data in 3D surface plots of two-variable functions. ...
Our algorithm successfully recovers shape information from synthetic 3D surface plots that have had axes and shading information removed, been rendered with a variety of grid types, and viewed from a range ...
from surface contours, suggesting high promise for use in automatic 3D plot and graphical model interpretation. ...
arXiv:2106.07627v1
fatcat:btjltjoazrfarfwpzwinggr7ne
Drawn To Customisation
2016
Proceedings of the 2016 ACM Conference Companion Publication on Designing Interactive Systems - DIS '16 Companion
This paper accompanies a demonstration at ACM SIGCHI -'Designing Interactive Systems' 2016 in Brisbane, Australia, of a 3D printer that has been hacked to automatically create and draw 2D portraits of ...
The paper and practical work calls attention to the novel process of using 3D Computer-Aided Design (CAD) algorithms to mimic the artistic practice of drawing abstract imagery of a live scene, displaying ...
The 3D environment controls the final size of the artwork, and may be scaled without loss of quality to suit any 3D printer or plotting system. ...
doi:10.1145/2908805.2908806
dblp:conf/ACMdis/Novak16
fatcat:7fkjrhq5srcvrlr7mb2lvogaqy
New Method for the Development of Sustainable STEP-Compliant Open CNC System
2016
Procedia CIRP
In this paper, a new method for the development of sustainable CNC system based on OAC and STEP-NC technologies is introduced. ...
The software system is composed of Machine Motion Control (MMC), ISO 14649-21 interpreter, and 3D Simulation (3DS) modules. ...
The plot points and lines functional module is responsible to take the axis positions (x, y and z) data from recite functional module and plot it into graphical form in 3D. ...
doi:10.1016/j.procir.2016.01.110
fatcat:ph25ifd4sncftkzfbxy7yb2zqa
Development of a feature-based open soft-CNC system
2016
The International Journal of Advanced Manufacturing Technology
The developed system employs a new set of techniques for STEP-NC data interpretation, graphical verification, execution, monitoring and report generation that supersede the exiting techniques in scope ...
thus detrimental to the basic resource independent philosophy of STEP-NC. ...
After plotting, the 360 • viewer functional block is executed that shows the plotting in various angles by rotating the Fig. 4 Algorithm design of STEP-NC interpretation module plotting image in 3D environment ...
doi:10.1007/s00170-016-9124-0
fatcat:eajmbak6gffe7m5x5zbmbuhgsy
Automated Canopy Delineation and Size Metrics Extraction for Strawberry Dry Weight Modeling Using Raster Analysis of High-Resolution Imagery
2020
Remote Sensing
The results of extracting four canopy size metrics (area, volume, average height, and height standard deviation) using automatically delineated and visually interpreted canopies were compared. ...
The trends observed in the differences between canopy metrics extracted using the automatically delineated and visually interpreted canopies showed no significant differences. ...
Conflicts of Interest: The authors declare no conflict of interest. ...
doi:10.3390/rs12213632
fatcat:h6hy3a6pbfeonoyrvj6khmtau4
Automatic Stem Mapping Using Single-Scan Terrestrial Laser Scanning
2012
IEEE Transactions on Geoscience and Remote Sensing
In this paper, an automatic plot-wise tree location mapping algorithm by using single-scan TLS is presented. The method detects the tree trunk based on range data and tree trunk model. ...
Eighty-five percent of trees that were manually found on the intensity image inside 60m range could be automatically found. ...
of Automatic, Detailed 3D Model Algorithms for Forests and Built Environment." ...
doi:10.1109/tgrs.2011.2161613
fatcat:5kn7dmg6frbrbdde3pmbpcndse
Computed reconstruction of spatial ammonoid-shell orientation captured from digitized grinding and landmark data
2014
Computers & Geosciences
By using a semi-automatic region growing algorithm of the 3D-visualization software Amira, ammonoids of a part of this mass occurrence were segmented and a 3D-model reconstructed. ...
However, disk-shaped fossils like planispiral cephalopods or gastropods were used, up to now, with caution for interpreting paleocurrents. ...
The authors thank Yeşim Islamoğlu (Ankara) and the General Directorate of Mineral Research and Exploration (Ankara) for the digging permission and the organization of two field trips. ...
doi:10.1016/j.cageo.2013.11.008
pmid:25843988
pmcid:PMC4375794
fatcat:rdgzkjbjhfeqpkib2om5mz3k2m
HDX-Viewer: interactive 3D visualization of hydrogen-deuterium exchange data
2019
Bioinformatics
However, bridging the gap between commercial HDX-MS software (for raw data interpretation) and molecular viewers (to map experiment results onto a 3D structure for biological interpretation) remains laborious ...
This user-friendly application automatically incorporates HDX-MS data from a custom template or commercial HDX-MS software in PDB files, and uploads them to an online 3D molecular viewer, thereby facilitating ...
HDX-MS results will then be plotted to the 3D structure on the right panel (Fig. 1) . ...
doi:10.1093/bioinformatics/btz550
pmid:31287496
pmcid:PMC6954641
fatcat:upqrjo3pzrdl5nrkzsq4hcpl3i
Automated 3D immunofluorescence analysis of Dorsal Root Ganglia for the investigation of neural circuit alterations: a preliminary study
2016
Position Papers of the 2016 Federated Conference on Computer Science and Information Systems
The analysis of 3D confocal images of dorsal root ganglia in diabetic mice, where different fluorescent markers are used to identify different types of nociceptors, can help understanding the unknown mechanisms ...
Nevertheless, due to the inherent challenges of 3D confocal imaging, a thorough and comprehensive visual investigation is very difficult. ...
C. 3D quantitative analysis The 3D sample is automatically characterized in terms of positive expression of each immunofluorescent marker. ...
doi:10.15439/2016f569
dblp:conf/fedcsis/CataldoTCFMFS16
fatcat:u2bzovirafej7oosmne7d2lfvy
Interactive 3D/2D visualization for geophysical data processing and interpretation
2009
Computers & Geosciences
., Interactive 3D/2D visualization for geophysical data processing and interpretation. ...
., Interactive 3D/2D visualization for geophysical data processing and interpretation. ...
However, the above programs still do not support interactive 3D plotting or provide integration with other data displays. ...
doi:10.1016/j.cageo.2008.10.005
fatcat:ab6mwbbpgzfxnokldwifhljixq
Comparison of 3D echocardiographic‐derived indices using fully automatic left ventricular endocardial tracing (heart model) and semiautomatic tracing (3DQ‐ADV)
2019
Echocardiography
The availability of a true 3D dataset provides an opportunity for automation of left ventricular (LV) and left atrial (LA) measurements. ...
Although manual and automated measurements of 3D volumes are known to correlate, the variance is an important parameter for the individual patient. The reasons for discrepancies remain unexplained. ...
Bland Altman plots and paired t-tests were used to assess the level of agreement between volumes as measured by automatic and semi-automatic echocardiography. ...
doi:10.1111/echo.14502
pmid:31621957
fatcat:f2enjfjbtffpxe4v5c2icqtrlq
Visual Workshop 2: a model viewer, editor and results display package for the ANSWERS shielding and criticality codes
2014
Progress in Nuclear Science and Technology
The main additional capabilities of version 2 are: Results display using 2D cell plots, 2D contour plots and 3D iso-surface plots overlaid on the model geometry; and display of event type, location and ...
The key features of Visual Workshop version 1 included interactive 2D and 3D ray trace display of the model using the same routines as the analysis code, wire frame display of the model, built in editing ...
Acknowledgements This acknowledges the input of the ANSWERS team who have all contributed to the development of Visual Workshop. ...
doi:10.15669/pnst.4.561
fatcat:lv5475r2hrbhlgusq2ibvhhyim
Automated Analysis of Binocular Alignment Using an Infrared Camera and Selective Wavelength Filter
2013
Investigative Ophthalmology and Visual Science
Full-face images were obtained with an infrared camera while a selective wavelength filter was placed in front of either eye. Images were analyzed using the 3D Strabismus Photo Analyzer. ...
The 95% limit of agreement of test-retest reliability between the PCT and selective wavelength filter analysis was 68.5 PD. ...
12 Techniques that can analyze the PCT automatically require minimal operator interpretation, and this can improve the reliability of manual measurements, as well as being efficient and more applicable ...
doi:10.1167/iovs.12-11400
pmid:23538061
fatcat:fqkfi672ezdudjjvvwdz5tfxj4
Quantitative 3D data extraction using contiguous volumes
1997
IEEE Transactions on Nuclear Science
A new image analysis method, called contiguous volume analysis, has been developed to automatically extract 3D information from emission images. ...
Since the analysis method is consistent with a visual inspection of the data, intuitive insights into the meaning of the data are possible, allowing a better understanding of the effects of the diflerent ...
Contiguous volume analysis automatically finds all of the hot volumes in the entire 3D image. ...
doi:10.1109/23.632734
fatcat:sp4t2iwazbgw7k2qhe3cfuffmq
MEMHDX: An interactive tool to expedite the statistical validation and visualization of large HDX-MS datasets
2016
Bioinformatics
The analysis of such extensive systems results in very large HDX-MS datasets for which specific analysis tools are required to speed up data validation and interpretation. ...
Motivation: With the continued improvement of requisite mass spectrometers and UHPLC systems, Hydrogen/Deuterium eXchange Mass Spectrometry (HDX-MS) workflows are rapidly evolving towards the investigation ...
Conflict of interest: none declared. ...
doi:10.1093/bioinformatics/btw420
pmid:27412089
pmcid:PMC5181559
fatcat:xjrnvhmltzcwbejjlprxehjmbm
« Previous
Showing results 1 — 15 out of 64,175 results