A copy of this work was available on the public web and has been preserved in the Wayback Machine. The capture dates from 2017; you can also visit the original URL.
The file type is application/pdf
.
Filters
TU-C-330A-07: Magnetic Resonance Electrical Impedance Mammography: A Feasibility Study
2006
Medical Physics (Lancaster)
; -to develop a method of quantitative description of MREIM effects; -to study MREIM effects based on simulation results; electric properties of normal and cancerous breast tissue;
-to conduct experimental ...
Since cancerous breast tissue has a higher electric conductivity than that of benign and normal breast tissue, electric conductivity may be used as a biomarker for detection of cancer (Fricke and Morse ...
doi:10.1118/1.2241500
fatcat:vlwnoiw6lvbnpmtowjxcganrb4
Electrical tissue property imaging using MRI at dc and Larmor frequency
2012
Inverse Problems
Since the conductivity and permittivity values exhibit frequencydependent changes, it is worthwhile to perform spectroscopic imaging from almost dc to hundreds of MHz. ...
To develop related imaging techniques, we should clearly understand the basic principles of MREIT and MREPT, which are based on coupled physics of bioelectromagnetism and MRI as well as associated mathematical ...
Various numerical simulation results and experimental studies using conductivity phantoms with known conductivity values demonstrated the validity of reconstructed conductivity images [90] . ...
doi:10.1088/0266-5611/28/8/084002
fatcat:4tqd3ycignai3kcetglt73axtu
Magnetic resonance electrical impedance tomography (MREIT): conductivity and current density imaging
2005
Journal of Physics, Conference Series
Acknowledgments This work was supported by grant R11-2002-103 from Korea Science and Engineering Foundation. ...
are from numerical simulations and phantom experiments. ...
Their results suggest that multi-frequency measurements of electrical conductivity and permittivity are promising for the diagnosis of cancerous lesions inside the human breast. ...
doi:10.1088/1742-6596/12/1/014
fatcat:falmptuoefcrppkvbvwlfo7ykq
Magnetoacoustic Imaging of Electrical Conductivity of Biological Tissues at a Spatial Resolution Better than 2 mm
2011
PLoS ONE
These results suggest the potential of MAT-MI for application to early detection of small-size diseased tissues (e.g. small breast cancer). ...
The actual spatial resolution of our MAT-MI system was experimentally determined to be 1.51 mm by a parallel-line-source phantom with Rayleigh criterion. ...
Acknowledgments The authors are grateful to Leo Mariappan for beneficial discussions.
Author Contributions Conceived and designed the experiments: GH BH. Performed the experiments: GH. ...
doi:10.1371/journal.pone.0023421
pmid:21858111
pmcid:PMC3155533
fatcat:h3l44k3dbbawnd7miyvymkwkyy
Proceedings of the 19th International Conference on Biomedical Applications of Electrical Impedance Tomography
[article]
2018
Zenodo
, Edinburgh, UK This document is the collection of papers accepted for presentation at the 19th International Conference on Biomedical Applications of Electrical Impedance Tomography. ...
Proceedings of the 19th International Conference on Biomedical Applications of ELECTRICAL IMPEDANCE TOMOGRAPHY Edited by Alistair Boyle, Nick Polydorides, Jiabin Jia June 11-13, 2018 Edinburgh University ...
Conclusions Studies in human breast anatomy are carried out in order to enhance the similar between simulation and real system. ...
doi:10.5281/zenodo.1306217
fatcat:2hft5xveivat5gfbptjh6l3iau
Advances in electrical impedance tomography-based brain imaging
2022
Military Medical Research
AbstractNovel advances in the field of brain imaging have enabled the unprecedented clinical application of various imaging modalities to facilitate disease diagnosis and treatment. ...
EIT offers many advantages over other neuroimaging technologies, which has led to its potential clinical use. ...
Acknowledgements The authors acknowledge Han-Bin Ma in CAS Key Laboratory of Bio-Medical Diagnostics, Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences for his patient ...
doi:10.1186/s40779-022-00370-7
pmid:35227324
pmcid:PMC8883715
fatcat:vp76epwkhzbaxhasy2f23qomxa
Proceedings Of The 18Th International Conference On Biomedical Applications Of Electrical Impedance Tomography
[article]
2017
Zenodo
of Engineering at Dartmouth, Hanover, New Hampshire, USA This document is the collection of papers accepted for presentation at the 18th International Conference on Biomedical Applications of Electrical ...
Proceedings of the 18th International Conference on Biomedical Applications of ELECTRICAL IMPEDANCE TOMOGRAPHY Edited by Alistair Boyle, Ryan Halter, Ethan Murphy, Andy Adler June 21-24, 2017 Thayer School ...
Measurements was conducted on male test subjects. Data analysis of the signal proposed the potential of this modality in regional pulmonary diagnostic. ...
doi:10.5281/zenodo.557093
fatcat:qn6cu4oazrefhmqgo6ykd4jxma
Proceedings Of The 18Th International Conference On Biomedical Applications Of Electrical Impedance Tomography
[article]
2017
Zenodo
of Engineering at Dartmouth, Hanover, New Hampshire, USA This document is the collection of papers accepted for presentation at the 18th International Conference on Biomedical Applications of Electrical ...
Proceedings of the 18th International Conference on Biomedical Applications of ELECTRICAL IMPEDANCE TOMOGRAPHY Edited by Alistair Boyle, Ryan Halter, Ethan Murphy, Andy Adler June 21-24, 2017 Thayer School ...
Measurements was conducted on male test subjects. Data analysis of the signal proposed the potential of this modality in regional pulmonary diagnostic. ...
doi:10.5281/zenodo.601555
fatcat:qhwameib6rd43krznqytsaeju4
A comparison of two EIT systems suitable for imaging impedance changes in epilepsy
2009
Physiological Measurement
breast cancer detection. ...
Acceptable images of test objects in the human head could be obtained with image reconstruction with the new meshes using experimental tank and simulated data. ...
Number EEC-9986821) and by NIBIB, the National Institute of Biomedical Imaging and Bioengineering under Grant Number R01-EB000456-03. ...
doi:10.1088/0967-3334/30/6/s07
pmid:19491447
fatcat:nzeetw52ofaslcwhd2kxylvlpu
Multi-excitation Magnetoacoustic Tomography With Magnetic Induction for Bioimpedance Imaging
2010
IEEE Transactions on Medical Imaging
Computer simulation and phantom experiment studies have been done to demonstrate the merits of the proposed method. ...
Benefits that come with this new method include better differentiation of tissue types with conductivity contrast using the MAT-MI approach, specifically for potential breast cancer screening application ...
Acknowledgments This work was supported in part by NIH R21EB006070, NSF BES-0602957, NIH RO1EB007920, RO1HL080093, and RO1EB006433. ...
doi:10.1109/tmi.2010.2052063
pmid:20529729
pmcid:PMC3033455
fatcat:563xuzcjbjaq5glkiyd6pig2ou
Imaging Electrical Impedance From Acoustic Measurements by Means of Magnetoacoustic Tomography With Magnetic Induction (MAT-MI)
2007
IEEE Transactions on Biomedical Engineering
We have conducted computer simulation and experimental studies on magnetoacoustic-tomography with magnetic induction (MAT-MI) for electrical impedance imaging. ...
Parameters of the model such as sample size, conductivity values, strength of the static and pulsed magnetic field, are set to simulate features of biological tissue samples and feasible experimental constraints ...
It may also have potential applications to breast cancer imaging and cancer imaging in other soft tissues. Manuscript received July 20, 2005, and revised June 3, 2006. ...
doi:10.1109/tbme.2006.883827
pmid:17278589
fatcat:yqdhgowz2vhqfbpboflypilkje
Magnetic-Resonance-Based Electrical Properties Tomography: A Review
2014
IEEE Reviews in Biomedical Engineering
Frequency-dependent electrical properties (EPs; conductivity and permittivity) of biological tissues provide important diagnostic information (e.g. tumor characterization), and also play an important role ...
Emphasizing on the imaging reconstruction methods rather than experimentation techniques, we review the developed imaging algorithms, validation results in physical phantoms and biological tissues, as ...
Acknowledgments This work was supported in part by NIH RO1EB006433, RO1EB007920, R21EB017069, R21EB009133, R21EB014353, P41RR008079, P30NS057091, and U01HL117664. The authors are grateful to Drs. P. ...
doi:10.1109/rbme.2013.2297206
pmid:24803104
pmcid:PMC4113345
fatcat:g74halcdmzgfjge4m3qv7mezpe
Magnetoacoustic tomography with magnetic induction (MAT-MI) for imaging electrical conductivity of biological tissue: a tutorial review
2016
Physics in Medicine and Biology
With all the reported and future technical advancement, MAT-MI has the potential to become an important noninvasive modality for electrical conductivity imaging of biological tissue. injection through ...
In addition, as a recently developed reverse mode of MAT-MI, magneto-acousto-electrical tomography with magnetic induction (MAET-MI) is briefly reviewed in terms of its theory and experimental studies. ...
Acknowledgement This work was supported in part by the National Institutes of Health under Grant EB014353, EB017069, and U01 HL117664 and in part by the National Science Foundation under Grant CBET-1450956 ...
doi:10.1088/0031-9155/61/18/r249
pmid:27542088
pmcid:PMC5056857
fatcat:qnofvcsybzhsbb7qutpwxpdt4q
Research on factors affecting the imaging resolution of magneto–acousto–electrical tomography
2020
IEEE Access
For instance, the conductivity of healthy breast tissues is much lower than that of breast cancer tissues, and the conductivity of muscle tissue is about ten times that of fat tissue [2] . ...
Numerical simulations and related imaging experiments on a multilayered phantom and a pork tissue sample were conducted by Liu et al. [15] . ...
COMPETING INTERESTS The authors report no conflicts of interest. ...
doi:10.1109/access.2020.3034741
fatcat:3cs45ffs3varhomjueutiqgc6y
Magnetoacoustic tomography with magnetic induction for high-resolution bioimepedance imaging through vector source reconstruction under the static field of MRI magnet
2014
Medical Physics (Lancaster)
Results: The image reconstruction through vector beamformation in the numerical and experimental studies gives a reliable estimate of the conductivity distribution in the object with a ∼1.5 mm spatial ...
Both numerical studies and phantom experiments are performed to demonstrate the merits of the proposed method. ...
Kamil Ugurbil for useful discussions and support in developing the experiment system and Dr. Xiaotong Zhang for useful discussions with the computer simulation. ...
doi:10.1118/1.4862836
pmid:24506649
pmcid:PMC3987704
fatcat:fdlzzua6s5edfhc656lswnze2e
« Previous
Showing results 1 — 15 out of 25 results