Filters








87 Hits in 13.1 sec

PIM-linearity improvement by the size of a diode mounting hole

Kenji Irie, Nobuhiro Kuga, Keizo Cho
2011 IEICE Electronics Express  
In 2 GHz-band experiment, we shows that the size reduction of the diode-mounted hole has an equivalent effect of the diode-rotation in the previous work, and contributes to the linearity improvement in  ...  A new method for the dynamic range enhancement of the PIM-producing patch antenna with diode is proposed, and its effectiveness is verified by experiment.  ...  In 2 GHz-band experiment, the size reduction of the diode-mounted hole contributed to the linearity improvement in the high power excitation, which was caused by the PIM reduction.  ... 
doi:10.1587/elex.8.1198 fatcat:nbnhckh3ozge5n3sn36fvhgldm

Layered Metals as Polarized Transparent Conductors [article]

Carsten Putzke, Chunyu Guo, Vincent Plisson, Martin Kroner, Thibault Chervy, Matteo Simoni, Pim Wevers, Maja D. Bachmann, John R. Cooper, Antony Carrington, Naoki Kikugawa, Jennifer Fowlie (+5 others)
2021 arXiv   pre-print
Technological solutions reflect this trade-off, achieving the desired transparencies by reducing the conductor thickness or carrier density at the expense of a lower conductance.  ...  Underlying this observation is the fabrication of out-of-plane slabs by focused ion beam milling.  ...  A slab of SRO was mounted on the edge of a silicon frame using two component epoxy. A part of the slab was hanging free over the hole in the frame allowing for transparency measurements.  ... 
arXiv:2107.08654v1 fatcat:4d3qn7jphne5bgyznsrckxaheu

Tunable diode laser gain measurements of the HF(2-0) overtone transitions in a small-scale HF laser

Charles F. Wisniewski, Gerald C. Manke II, Gordon D. Hager, Peter G. Crowell, C. Randall Truman, Steven J. Davis, Michael C. Heaven
2002 Gas and Chemical Lasers and Intense Beam Applications III  
A tunable diode laser was used to probe the overtone gain medium of a small-scale HF laser.  ...  Two-dimensional, spatially resolved small signal gain and temperature maps were generated for the P(3) ro-vibrational transition in the first HF overtone band. Io0(vo)) 1 g1i1  ...  In the case of the PSN device, if an effective path length of 14.9 cm is assumed for the PSN device (i.e. the path length predicted by CFD calculations of the size of the active medium), then the small  ... 
doi:10.1117/12.465779 fatcat:mk4rjg6nlvfhrgfzjqboqn7plq

Vacuum-ultraviolet photodetectors

Lemin Jia, Wei Zheng, Feng Huang
2020 PhotoniX  
This paper takes ultra-wide bandgap semiconductor filterless VUV photodetectors with different working mechanisms as the object and gives a systematic review in the aspects of figures of merit, performance  ...  High-performance vacuum-ultraviolet (VUV) photodetectors are of great significance to space science, radiation monitoring, electronic industry and basic science.  ...  The illustration presents a close-up view (linear scale) to show the improved stability of the detector at + 25 V [97] . f Spectral responsivity of MSM-AlN-008 (2 mm in diameter) within the wavelength  ... 
doi:10.1186/s43074-020-00022-w fatcat:ycn2s45hyzfq3djllmt5g7aiby

Perovskite-Inspired Materials for Photovoltaics – From Design to Devices [article]

Yi-Teng Huang, Sean R. Kavanagh, David O. Scanlon, Aron Walsh, Robert L. Z. Hoye
2020 arXiv   pre-print
Finally, the prospects and key challenges faced by the field in advancing the development of perovskite-inspired materials towards realization in commercial devices is discussed.  ...  The atomistic origins of the extraordinary performance exhibited by lead-halide perovskites in photovoltaic devices is discussed, alongside the key challenges in engineering such high-performance in alternative  ...  diodes and radiation detectors).  ... 
arXiv:2008.08959v1 fatcat:oixxcqbl5ne7php2v4p43fvfou

Perovskite-Inspired Materials for Photovoltaics and Beyond – From Design to Devices

Yi-Teng Huang, Seán R. Kavanagh, David O Scanlon, Aron Walsh, Robert Hoye
2020 Nanotechnology  
Finally, the prospects and key challenges faced by the field in advancing the development of perovskite-inspired materials towards realization in commercial devices is discussed.  ...  The atomistic origins of the extraordinary performance exhibited by lead-halide perovskites in photovoltaic devices is discussed, alongside the key challenges in engineering such high-performance in alternative  ...  Seán R Kavanagh acknowledges funding from the EPSRC Centre for Doctoral Training in Advanced Characterisation of Materials (CDT-ACM)( EP/S023259/1), as well as the use of VESTA [477] (for crystal structure  ... 
doi:10.1088/1361-6528/abcf6d pmid:33260167 fatcat:75zfppqbrjddfn2eo7wklzbn7a

IEEE/Cornell Conference on Advanced Concepts in High Speed Semiconductor Devices and Circuits

1987 IEEE/Cornell Conference on Advanced Concepts in High Speed Semiconductor Devices and Circuits, 1987. Proceedings.  
so designated by other documentation. 12a.  ...  the data needed, and completing and reviewing the collection of information.  ...  Air Force Office of Scientific Research (program number F49620-92-0464) and an associated AASERT contract, by a National Science Foundation Presidential Young Investigator Award, and by the DARPA Optoelectronics  ... 
doi:10.1109/cornel.1987.721206 fatcat:kwwfh234a5cx5njrhddhkwhi6e

Large Spaceborne Deployable Antennas (LSDAs) -A Comprehensive Summary

Baoyan DUAN
2020 Chinese journal of electronics  
This paper provides a survey of research activities of Large spaceborne deployable antennas (LSDAs) in the past, present and future.  ...  Firstly, three main kinds of spaceborne antennas, such as solid reflector, inflatable reflector and mesh reflector, are issued by showing the strengths and weaknesses.  ...  Acknowledgement: The author would like to show his special thanks to Prof. DU Jingli and ZHANG Yiqun, Associate Professor ZHANG Shuxin, and other Ph.D. & M.S. students.  ... 
doi:10.1049/cje.2019.09.001 fatcat:5a6w72khyjfrzk6y6qjaw32ldq

Clinical and Basic Evaluation of the Prognostic Value of Uric Acid in Traumatic Brain Injury

Han Liu, Junchi He, Jianjun Zhong, Hongrong Zhang, Zhaosi Zhang, Liu Liu, Zhijian Huang, Yue Wu, Li Jiang, Zongduo Guo, Rui Xu, Weina Chai (+3 others)
2018 International Journal of Medical Sciences  
UA treatment also improved neuronal maintenance and cortical blood flow (P<0.05) but not lesion size (P>0.05).  ...  Following TBI, active antioxidant defense in the brain may result in consumption of UA in the serum, and thus, a decreased serum UA level could be predictive of good clinical recovery.  ...  Additionally, adjustment of the size of the test area was performed by PIM Software version 1.5.  ... 
doi:10.7150/ijms.25799 pmid:30013449 pmcid:PMC6036155 fatcat:a5wibuhym5g2tadre6xyroldfa

Automated multifilter rotating shadow-band radiometer: an instrument for optical depth and radiation measurements

Lee Harrison, Joseph Michalsky, Jerry Berndt
1994 Applied Optics  
Thus the long-term stability of all three measured components can be tied to the solar constant by an analysis of the routinely collected data.  ...  resolved measurements at seven wavelength passbands (chosen at the time of manufacture between 350 nm and 1.7 pim) of direct-normal, total-horizontal, and diffuse-horizontal irradiances.  ...  These diodes are mounted to the interior of a five-sided cubic printed circuit board that provides a separate transimped- ance amplifier (zero-bias current-to-voltage amplifier) for each of the photodiodes  ... 
doi:10.1364/ao.33.005118 pmid:20935895 fatcat:ruzz6fxlsnczzjuqelsdmsay6i

Spatial and temporal beam profile monitor with nanosecond resolution for CERN's Linac4 and Superconducting Proton Linac

M. Hori, K. Hanke
2008 Nuclear Instruments and Methods in Physics Research Section A : Accelerators, Spectrometers, Detectors and Associated Equipment  
The ion beam first struck a carbon foil, and secondary electrons emerging from the foil were accelerated by a series of parallel grid electrodes.  ...  The time resolution was attained by applying high-voltage pulses of sub-nanosecond rise and fall times to the grids.  ...  The screen was then mounted on a larger ceramic frame of size 200 mm  150 mm and thickness t d ¼ 3 mm (Fig. 3(b) ).  ... 
doi:10.1016/j.nima.2008.01.078 fatcat:brergltbgvdu3atiub4eq44v6y

Observing distant objects with a multimode fibre-based holographic endoscope [article]

Ivo T. Leite
2020 arXiv   pre-print
As a proof-of-concept, we provide imaging inside the cavities of a sweet pepper commonly used as a phantom for biomedically relevant conditions.  ...  end of the instrument.  ...  MartinŠiler is gratefully acknowledged for a C library allowing efficient parallel computation of the DMD patterns.  ... 
arXiv:2011.03600v1 fatcat:lenpt5433ncrheebrhuhhj2zmy

Electromigration Testing of Al-Alloy Films

P. B. Ghate
1981 19th International Reliability Physics Symposium  
These micrographs have been used to determine the average grain size by a linear intercept method. 2° (rain size distribution has been examined by constructing the histograms.  ...  Al+Cu Film Conductors Data presented in Table 8 strongly suggest a definite improvement in MTF, almost by a factor of 3 to 4, with the addition of Cu to Al.  ... 
doi:10.1109/irps.1981.363004 fatcat:hpuzs6zljvfshoacacdzaveery

Abstracts of Papers from other Journals

1972 Journal of the SMPTE  
The VANGUARD Model XR-35 Flickerless Projector is versatile and easy to operate. Designed for analysis of 35mm motion picture and X-Ray film.  ...  FEATURES: 0 full cine s eed (30fps) for normal motion picfure viewing 0 low scan speed (6fps) for slowing down motion 0 single frame advance for frame by frame analysls 0 forward and reverse film travel  ...  An improved Coordinated Universal Time (UTC) system has been adopted by the International Radio Consultative Committee (CCIR).  ... 
doi:10.5594/j08246 fatcat:kyaj2n2ww5gktmfsrconyyqjwq

Power pulsing of the CALICE tile hadron calorimeter

Mathias Reinecke
2016 2016 IEEE Nuclear Science Symposium, Medical Imaging Conference and Room-Temperature Semiconductor Detector Workshop (NSS/MIC/RTSD)  
Nevertheless, as a result of a series of innovative large experiments in the last 20 years, we have learnt a great deal about neutrinos.  ...  I will also discuss the complementary experimental approaches being adopted by the Hyper-Kamiokande experiment in Japan and the JUNO experiment in China.  ...  M04D-15: Monte Carlo Simulation of DNA Damage Clustering Induced by a 24 MeV Proton Beam The authors want to thank Professor Lars R.  ... 
doi:10.1109/nssmic.2016.8069748 fatcat:zjgd7dmfdbhntb4kfwdtrlejhi
« Previous Showing results 1 — 15 out of 87 results