More Knowledge Is Better: Cross-Modality Volume Completion and 3D+2D Segmentation for Intracardiac Echocardiography Contouring [chapter]

Haofu Liao, Yucheng Tang, Gareth Funka-Lea, Jiebo Luo, Shaohua Kevin Zhou
2018 Lecture Notes in Computer Science  
However, it is a challenge to build an automatic contouring algorithm because ICE is noisy and provides only a limited 2D view of the 3D anatomy.  ...  Experimental results show that our model is significantly better than a direct 2D image-to-image deep neural network segmentation, especially for less-observed structures.  ...  It uses 3D geometry and cross-modality appearance knowledge for better anatomical understanding and structural consistency.  ... 
doi:10.1007/978-3-030-00934-2_60 fatcat:t5ntrghwszaebbb6yn46rq3sfi

Three-dimensional binding sites volume assessment during cardiac pacing lead extraction

Bich Lien Nguyen, Alessandro Persi, Eli S. Gang, Fabrizio Fattorini, Alessandra Oliva, Antonio Vitarelli, Nicola Alessandri, Robert J. Siegel, Antonio Ciccaglioni, Carlo Gaudio
2015 Clinical Trials and Regulatory Science in Cardiology  
Conclusions: Real-time 3D binding sites assessment is feasible and improves transvenous lead extraction outcomes.  ...  Results: CartoSound was able to detect more intracardiac binding sites compared to fluoroscopy (RA 17.4% vs. 4.3%, p = 0.04; RV 43.5% vs. 21.7%, p = 0.04), but was unable to assess the subclavian/innominate  ...  Acknowledgments We thank Fabrizio Piergentili for his assistance.  ... 
doi:10.1016/j.ctrsc.2015.08.006 fatcat:355h2smibfgkppbqzjsokt2fou

Three-dimensional echocardiography in congenital heart disease

John Simpson, Annemien E. van den Bosch
2019 Echo Research and Practice  
Three dimensional echocardiography is a valuable tool for the assessment of cardiac function where it permits calculation of chamber volume and function.  ...  Enhancements of image processing to include intracavity flow, image fusion and true 3D displays look set to further improve the contribution of this modality to care of the patient with congenital heart  ...  A full-volume 3D data set is acquired and segmented into four-chamber, sagittal and coronal views.  ... 
doi:10.1530/erp-18-0074 pmid:31026813 pmcid:PMC6528493 fatcat:wcc2bkbfd5hlfctoeqckjqwxni

Value of Real-Time Transesophageal 3-Dimensional Echocardiography in Guiding Ablation of Isthmus-Dependent Atrial Flutter and Pulmonary Vein Isolation

Francesco F. Faletra, François Regoli, Marta Acena, Angelo Auricchio
2012 Circulation Journal  
Real-time 3-dimensional transesophageal echocardiography (RT 3D TEE) has emerged as a new imaging tool in the clinical arena.  ...  This progress is attributed to both the accumulating experience of electrophysiologists and the advances in technological tools facilitating the diagnosis and treatment of cardiac arrhythmias.  ...  In more challenging cases, 2D TEE is used as the primary imaging modality to guide trans-septal crossing. 21 The most appropriate site of puncture (ie, fossa ovalis) is identified through recognition  ... 
doi:10.1253/circj.cj-11-1040 pmid:21979147 fatcat:x5fvslmctrf3jbyib5i437clca

Heterogeneity in age related central arterial stiffening: ascending aortic stiffness is a better predictor of carotid to femoral pulse wave velocity and brachial peripheral blood pressure than carotid stiffness

Alban Redheuil, Wen Yu, Raymond T Yan, Elie Mousseaux, Alain De Cesare, David A Bluemke, Joao AC Lima
2009 Journal of Cardiovascular Magnetic Resonance  
Contrast enhanced cardiovascular magnetic resonance imaging (ceCMR) can detect and quantify myocardial fibrosis in the setting of CMI and might therefore be a valuable tool for a more accurate risk stratification  ...  VA is related to infarct size and seems to be related to infarct morphology.  ...  Conclusion: We have developed and technically validated an automatic delineation algorithm for multi-echo CMR images. The resulting contours are accurate and allow for accurate T2* quantification.  ... 
doi:10.1186/1532-429x-11-s1-p245 fatcat:ec2fpqie3ffiddmt7hzxctra4a

Multimodal Registration and Data Fusion for Cardiac Resynchronization Therapy Optimization

Francois Tavard, Antoine Simon, Christophe Leclercq, Erwan Donal, Alfredo I. Hernandez, Mireille Garreau
2014 IEEE Transactions on Medical Imaging  
Their measurement is based on the fusion of anatomical, functional and electrical data acquired using computed tomography (CT), speckle tracking echocardiography (STE) and electro-anatomical mappings (  ...  It implies the fusion of electrical and mechanical data on a 3D+t anatomical model of the left ventricle (LV).  ...  The metric value (eq. 5) is then computed between the 3D+t CT surfaces and the transformed simulated 2D+t contours.  ... 
doi:10.1109/tmi.2014.2311694 pmid:24893260 fatcat:n5f6imvhffhotdhzq2qvah4f6a

Rapid Prototyping: A New Tool in Understanding and Treating Structural Heart Disease

M. S. Kim, A. R. Hansgen, O. Wink, R. A. Quaife, J. D. Carroll
2008 Circulation  
multiple compelling new reasons to better understand cardiac anatomic and spatial relationships.  ...  As the appreciation of structural heart disease in children and adults has increased and as catheter-based closure procedures are now being performed in clinical practice, cardiovascular physicians have  ...  with congenital and acquired structural heart disease for rapid prototyping.  ... 
doi:10.1161/circulationaha.107.740977 pmid:18458180 fatcat:usfuah5tafde5e6gn35yarxwoq

Multimodality Imaging Guidelines for Patients with Repaired Tetralogy of Fallot: A Report from the American Society of Echocardiography

Anne Marie Valente, Stephen Cook, Pierluigi Festa, H. Helen Ko, Rajesh Krishnamurthy, Andrew M. Taylor, Carole A. Warnes, Jacqueline Kreutzer, Tal Geva
2014 Journal of the American Society of Echocardiography  
compared with 2D-based measurements, 3D echocardiography provides more accurate and reproducible quantification of RV volumes. 23, [42] [43] [44] [45] [46] However, a meta-analysis suggested that 3D  ...  to allow routine use of 3D echocardiography in the quantification of RV volumes and EF.  ... 
doi:10.1016/j.echo.2013.11.009 pmid:24468055 fatcat:reu72j6wffa7rddor35lb3xc44

Cardiothoracic Applications of 3-dimensional Printing

Andreas A. Giannopoulos, Michael L. Steigner, Elizabeth George, Maria Barile, Andetta R. Hunsaker, Frank J. Rybicki, Dimitris Mitsouras
2016 Journal of thoracic imaging  
In summary, cardiothoracic 3D printing is rapidly evolving and may be a potential game-changer for surgeons.  ...  The most comprehensive medical 3D printing software is the Mimics suite (Materialise, Leuven, Belgium) which includes the most extensive set of segmentation and CAD tools.  ...  STL Model Generation Tissues that have been segmented by demarcating their boundaries in the individual, successive 2D cross-sectional images that compose the 3D image volume cannot be directly 3D-printed  ... 
doi:10.1097/rti.0000000000000217 pmid:27149367 pmcid:PMC4993676 fatcat:ixfhptoafrcedlw7ypszof46kq

Role of Imaging in Left Atrial Appendage Occlusion

Mathieu Lempereur, Adel Aminian, Raluca Dulgheru, Tom De Potter, Cécile Oury, Patrizio Lancellotti
2017 International Journal of Cardiovascular Practice  
Multimodality imaging, including 2D/3D echocardiography, fluoroscopy, and cardiac computed tomography can increase the safety and efficacy of the procedure.  ...  Multimodality imaging is key in the understanding of 3D aspects of the LAA and surrounding structures anatomy.  ...  After implantation, the device can be visualized more completely with 3D TOE [14, [20] [21] [22] [23] .  ... 
doi:10.21859/ijcp-020203 fatcat:wtlfhz2yuveslfsfublwlt5wmm

What is the minimum change in left ventricular ejection fraction, which can be measured with contrast echocardiography?

Tan Suwatanaviroj, Weimin He, Edith Pituskin, Ian Paterson, Jonathan Choy, Harald Becher
2018 Echo Research and Practice  
Contrast echocardiography is a reliable tool for serial measurements of EF to monitor cardiotoxicity due to chemotherapy.  ...  The MDD for EF, end-diastolic volume and end-systolic volume that could be recognized with 95% confidence interval were 4 percentage points, 7 mL and 4 mL, respectively.  ...  Funding This research did not receive any specific grant from any funding agency in the public, commercial or not-for-profit sector.  ... 
doi:10.1530/erp-18-0003 pmid:29643125 pmcid:PMC5948195 fatcat:cijh7utdxzg4xexklvckujyioa

Cardiovascular Magnetic Resonance Imaging for Structural and Valvular Heart Disease Interventions

João L. Cavalcante, Omosalewa O. Lalude, Paul Schoenhagen, Stamatios Lerakis
2016 JACC: Cardiovascular Interventions  
After acquisition is completed, the entire 3D dataset can be manipulated using an off-line workstation for post-processing.  ...  CMR is well-established as an excellent noninvasive imaging modality for the diagnosis of patients with suspected intracardiac shunting and/or for the follow-up post-corrective surgery.  ...  Go to http://www.acc.org/jaccjournals-cme to take the CME quiz for this article.  ... 
doi:10.1016/j.jcin.2015.11.031 pmid:26965931 fatcat:xf7fy3stavgbpafbulyfqgkntm

Three-dimensional echocardiography in mitral valve disease

G VALOCIK, O KAMP, C VISSER
2005 European Journal of Echocardiography  
et al 33 found 3D volume-rendered echocardiography to be superior to 2D echocardiography for the evaluation of commissures.  ...  Different structures can be examined en face with better perception of the anatomic relationships. The ideal for 3D reconstruction is real-time 3D echocardiography (RT3D).  ...  I am very grateful for their support to continue and complete this thesis. Particularly, I am indebted to Dr.  ... 
doi:10.1016/j.euje.2005.02.007 pmid:16293531 fatcat:omdbeavv7fft7czcrvujffu4ai

Consensus on Perioperative Transesophageal Echocardiography of the Brazilian Society of Anesthesiology and the Department of Cardiovascular Image of the Brazilian Society of Cardiology

Marcello Fonseca Salgado-Filho, Samira Saady Morhy, Henrique Doria de Vasconcelos, Eric Benedet Lineburger, Fabio de Vasconcelos Papa, Eduardo Souza Leal Botelho, Marcelo Ramalho Fernandes, Maurício Daher, David Le Bihan, Chiara Scaglioni Tessmer Gatto, Cláudio Henrique Fischer, Alexander Alves da Silva (+4 others)
2018 Brazilian Journal of Anesthesiology  
is emphasized in the complete assessment of AV and LVOT and measurement of ejection systolic volume and cardiac output. 2D imaging and Doppler of ascending aorta The necessary cross-sections  ...  valve and aorta The 3D echocardiographic image is acquired by capturing an anatomical image volume (Fig. 24), defined in its size by the operator, unlike the 2D echocardiography acquired by  ... 
doi:10.1016/j.bjane.2017.09.001 fatcat:rx4ocwkicna2zajfiopdfys6vy

Medical Image Analysis on Left Atrial LGE MRI for Atrial Fibrillation Studies: A Review [article]

Lei Li and Veronika A. Zimmer and Julia A. Schnabel and Xiahai Zhuang
2022 arXiv   pre-print
This paper aims to provide a systematic review on computing methods for LA cavity, wall, scar and ablation gap segmentation and quantification from LGE MRI, and the related literature for AF studies.  ...  Although several methods have been proposed, especially for LA segmentation, there is still large scope for further algorithmic developments due to performance issues related to the high variability of  ...  Acknowledgment This work was supported by the National Natural Science Foundation of China (61971142, 62111530195 and 62011540404) and the development fund for Shanghai talents (2020015).  ... 
arXiv:2106.09862v3 fatcat:y7gk5bjqirgotbx3bwfq62rnqy