Filters








720 Hits in 6.0 sec

Three-dimensional display of cortical anatomy and vasculature: Magnetic resonance angiography versus multimodality integration

Christopher J. Henri, G. Bruce Pike, D. Louis Collins, Terence M. Peters
1991 Journal of digital imaging  
The second approach is based on the integration of x-ray projection angiograms and tomographic image data. allowing a composite image of anatomy and vasculature to be viewed in 3D.  ...  This is accomplished by superimposing an angiographic stereo-pair onto volume rendered images of either CT or MR data created with matched viewing geometries.  ...  Evans and S. Marrett for their interest and assistance in this work.  ... 
doi:10.1007/bf03173871 pmid:2029569 fatcat:d3vvafr2jjgnlob2c2yluksivi

Real-time registration of 3D cerebral vessels to X-ray angiograms [chapter]

Yasuyo Kita, Dale L. Wilson, J. Alison Noble
1998 Lecture Notes in Computer Science  
MR Angiogram), to a X-ray image of the vessel (eg.Digital Subtraction Angiogram) taken during an operation.  ...  A quick method to obtain the 3D transformation of a 3D freeform shape model from its 2D projection data is proposed.  ...  Byrne and Dr D. Royston for their clinical advice and the data used for the experiments. The first author thanks STA's middle-term researcher sending scheme.  ... 
doi:10.1007/bfb0056302 fatcat:wwn6hm7l3vhnjdzz57g6m5gl6a

Registration and Fusion of Contrast-Enhanced MRI Myocardial Substrate Maps and X-ray Angiograms

Juan E. Ortuño, Esther Pérez-David, Angel Arenal, Javier Bermejo, Andrés Santos, María J. Ledesma-Carbayo
2013 International Conference on Computing in Cardiology  
Fusion of angiograms with SI maps was treated as a 2D-3D pose estimation, where each image point is projected to a Plücker line, and the screw representation for rigid motions is minimized using a gradient  ...  The aim of this work is to provide the necessary methods to register and fuse the endo-epicardial signal intensity (SI) maps extracted from contrast-enhanced magnetic resonance imaging (ceMRI) with X-ray  ...  Instead of repeating the 3D-2D registration between model points X i and image points x i for every angiogram, a relative orientation problem is proposed: The recovery of the position and orientation of  ... 
dblp:conf/cinc/OrtunoPABSL13 fatcat:4ywvzhojnbef5efjh7logor56q

Dynamic contrast-enhanced MR angiography and MR imaging of the carotid artery: high-resolution sequences in different acquisition planes

S Aoki, H Nakajima, H Kumagai, T Araki
2000 American Journal of Neuroradiology  
We evaluated the clinical utility of performing 3D contrast-enhanced MR angiography in the axial plane immediately after performing angiography in the coronal plane.  ...  Coronal 3D MR angiography was performed after administering a bolus injection of contrast material (20 mL) with automatic triggering. This was immediately followed by an axial acquisition.  ...  Twenty carotid arteries of 33 patients who had both contrast-enhanced MR angiography and X-ray DSA showed more than 0% stenosis by NASCET criteria and were used for this analysis.  ... 
pmid:10696027 pmcid:PMC7975334 fatcat:kiosvo5honbu5owc7cqdnv53aa

Multimodal angiographic assessment of cerebral arteriovenous malformations: a pilot study

Raphaël Blanc, Aude Seiler, Thomas Robert, Humain Baharvahdat, Maxime Lafarge, Julien Savatovsky, Jérôme Hodel, Gabriele Ciccio, Dorian Chauvet, Silvia Pistocchi, Bruno Bartolini, Hocine Redjem (+1 others)
2014 Journal of NeuroInterventional Surgery  
machine based 3D2D registration of 3D RA and real time 2D Diagnostic 3D MRI fluoroscopy data (figure 2).21 22 After 3D RA acquisition, the MR imaging  ...  (B) Superposition of 3D RA/superselective angiogram and MR (volume rendering mode).  ... 
doi:10.1136/neurintsurg-2014-011402 pmid:25280569 pmcid:PMC4680193 fatcat:gual5df73racxby7xvsrisntze

Subject index

1999 IEEE Transactions on Medical Imaging  
Tianpeng Wang, + , T-MI Mar 99 239-251 stereoscopic X-ray angiography, rot. C-arm, modeling/optim.  ...  Frangi, A.F., + , T-MI Oct 99 946-956 Sun, Y., + , T-MI Dec 99 1154-1169 stereoscopic X-ray angiography, rot. C-arm, modeling/optim.  ...  -based eval. of image-proc. and class. methods. Kwan, R.K.-S., + , T-MI Nov. 1999  ... 
doi:10.1109/tmi.1999.819331 fatcat:g7ntb6icpzgs7jwncaguherqne

Reliability and Validity of Noninvasive Imaging of Internal Carotid Artery Pseudo-Occlusion

G. Furst, A. Saleh, F. Wenserski, J. Malms, M. Cohnen, A. Aulich, T. Neumann-Haefelin, M. Schroeter, H. Steinmetz, M. Sitzer
1999 Stroke  
; 2D and 3D time-of-flight techniques), color Doppler-assisted duplex imaging (CDDI) and power-flow imaging (PFI) with and without an intravenous ultrasonic contrast agent.  ...  and 0.47 for 3D MRA, respectively.  ...  C and D, 2D and 3D TOF MR angiograms (lateral views) reveal ICA patency (arrows). 2D TOF MRA (C) provides slightly better contrast.  ... 
doi:10.1161/01.str.30.7.1444 pmid:10390321 fatcat:lfrpklnbl5gtdl54nvir3w3wxe

Vessel diameter measurements in gadolinium contrast-enhanced three-dimensional MRA of peripheral arteries

Jos J.M. Westenberg, Rob J. van der Geest, Martin N.J.M. Wasser, Edwin L. van der Linden, Theo van Walsum, Hans C. van Assen, Albert de Roos, Jan Vanderschoot, Johan H.C. Reiber
2000 Magnetic Resonance Imaging  
Diameters measured in the selective MIPs were smaller than those measured in the X-ray angiograms (mean difference 0.49 mm) and this difference was statistically significant (p Ͻ 0.01).  ...  Diameter values from the selective MIPs of the aorto-iliac arteries were also compared with diameter values measured at corresponding anatomic positions in X-ray angiograms of these patients (i.e., D X  ...  With MRA, 3D information about lesions can be obtained while with standard X-ray angiography, arteries can only be visualized in 2D projections.  ... 
doi:10.1016/s0730-725x(99)00099-5 pmid:10642098 fatcat:jc2eevz7s5aatppwcragmpw7bi

2D-3D Intensity Based Registration of DSA and MRA - A Comparison of Similarity Measures [chapter]

John H. Hipwell, Graeme P. Penney, Tim C. Cox, James V. Byrne, David J. Hawkes
2002 Lecture Notes in Computer Science  
We have compared the performance of six similarity measures for registration of three-dimensional (3D) magnetic resonance angiography (MRA) to two-dimensional (2D) x-ray angiography images of the cerebral  ...  Of the six similarity measures, pattern intensity, gradient difference and gradient correlation performed consistently accurately and robustly for all data sets.  ...  Acknowledgments We would like to thank Kawaldeep Rhode, Robert McLaughlin, Albert Chung and Paul Summers for their assistance in acquiring the images used in this paper and also Kawaldeep Rhode for distortion  ... 
doi:10.1007/3-540-45787-9_63 fatcat:jtwx7kntkzfuxj5jxky7odjmz4

Magnetic resonance angiography

M J Graves
1997 British Journal of Radiology  
Angiograms can be produced using either the time-of-flight (TOF) or phase contrast (PC) methods.  ...  Magnetic resonance angiography (MRA) permits the non-invasive visualization of blood flow through the effects of moving spins on the magnetic resonance signal.  ...  Sandra Powell, Erica Scurr and Sue Cleminson are thanked for their assistance in collecting the data for Figures 3, 4, 6, 7, 9, 11 and 14 all of which were acquired using a 1.5 T IGE Signa Advantage  ... 
doi:10.1259/bjr.70.829.9059290 pmid:9059290 fatcat:siso5ubmt5bwzb2ocgbw5wyj4y

CT Image Registration in Acute Stroke Monitoring [article]

Lucio Amelio, Alessia Amelio
2018 arXiv   pre-print
A new similarity measure is also introduced for the comparison of the source and target images during image registration.  ...  It will result in a cheaper, faster and more accessible evaluation of the acute phase of the stroke overcoming the current limitations of the proposed systems in the state-of-the-art.  ...  In particular, the patient is exposed to an x-rays beam. The projected image is captured on a semicircular x-ray detector. The patient is po- sitioned between the x-ray source and the detector.  ... 
arXiv:1806.10836v1 fatcat:6dlrk3bwejaypcpwqazd2r2vcq

A novel method for improving the accuracy of MR-derived patient-specific vascular models using X-ray angiography [article]

John D. Horn, Zbigniew A Starosolski, Michael J. Johnson, Avner Meoded, Shaolie S. Hossain
2021 bioRxiv   pre-print
We have developed a novel method to improve the accuracy of MR-derived 3D vascular models utilizing 2D X-ray angiography (XA), which is considered the gold standard for clinically assessing vessel caliber  ...  In this workflow, ″virtual angiographies″ (VA) of 3D MR-derived vascular models are conducted, producing 2D projections that are compared to corresponding XA images guiding the local adjustment of modeled  ...  to the x-ray source and detector).  ... 
doi:10.1101/2021.12.22.472309 fatcat:vqpapeovqvdrheykpypnead3ty

New techniques and applications for magnetic resonance angiography

Jeffrey P Goldman
2003 The Mount Sinai journal of medicine  
This article describes some of the new techniques and applications of MRA in clinical practice today.  ...  Recent technological advances in magnetic resonance imaging have transformed the field of magnetic resonance angiography (MRA) from a research tool into an important clinical examination that is gaining  ...  risks and dangers associated with conventional X-ray contrast angiography.  ... 
pmid:14647872 fatcat:dypj6dclirdufbtpgv227mndxi

Noninvasive Coronary Vessel Wall and Plaque Imaging With Magnetic Resonance Imaging

R. M. Botnar, M. Stuber, K. V. Kissinger, W. Y. Kim, E. Spuentrup, W. J. Manning
2000 Circulation  
Background-Conventional x-ray angiography frequently underestimates the true burden of atherosclerosis.  ...  Methods and Results-Ten subjects, including 5 healthy adult volunteers (aged 35Ϯ17 years, range 19 to 56 years) and 5 patients (aged 60Ϯ4 years, range 56 to 66 years) with x-ray-confirmed coronary artery  ...  The authors thank Dr Leo Mollewanger and Jouke Smink from Philips Medical Systems, Best, The Netherlands, for their many helpful discussions.  ... 
doi:10.1161/01.cir.102.21.2582 pmid:11085960 fatcat:x55k7cpv4zhitid5bdcod74pdi

Temporal tracking of 3D coronary arteries in projection angiograms

Guy Shechter, Frederic Devernay, Eve Coste-Maniere, Elliot R. McVeigh, Milan Sonka, J. Michael Fitzpatrick
2002 Medical Imaging 2002: Image Processing  
The method has been applied to patient data and results are presented.  ...  on arterial length and regularity, which lack meaning in 2D projection space, are directly applicable in 3D; and (3) tracking arterial segments through occlusions and crossings in the projection images  ...  patient data, and Jason Lee for construction of the calibration grid and phantom.  ... 
doi:10.1117/12.467204 dblp:conf/miip/ShechterDCM02 fatcat:ajpzxqx775aclo5ys5mgsa6xaa
« Previous Showing results 1 — 15 out of 720 results