Filters








38 Hits in 18.6 sec

Detection of different kidney stone types: an ex vivo comparison of ultrashort echo time MRI to reference standard CT

El-Sayed H. Ibrahim, Joseph G. Cernigliaro, Robert A. Pooley, Mellena D. Bridges, Jamie G. Giesbrandt, James C. Williams, William E. Haley
2016 Clinical imaging  
and Purpose-With the development of ultrashort echo time (UTE) sequences, it may now be possible to detect kidney stones by using magnetic resonance imaging (MRI).  ...  Methods-One hundred and fourteen kidney stones were inserted into agarose and urine phantoms and imaged on both a dual-energy CT scanner using a standard renal stone imaging protocol and on an MRI scanner  ...  The recent development of ultra-short echo time (UTE) sequencing with TE's in the microseconds has allowed for the possibility of imaging kidney stones with MR.  ... 
doi:10.1016/j.clinimag.2015.09.005 pmid:26526527 pmcid:PMC5485418 fatcat:5onswq6mdbdepev6tvwk3v6fkm

5th International Symposium on Focused Ultrasound

Menashe Zaaroor, Alon Sinai, Dorit Goldsher, Ayelet Eran, Maria Nassar, Ilana Schlesinger, Jonathon Parker, Vinod Ravikumar, Pejman Ghanouni, Sherman Stein, Casey Halpern, Vibhor Krishna (+1008 others)
2016 Journal of Therapeutic Ultrasound  
Contrast T1 and T2* images allowed semi-real time confirmation of BBB disruption and safety, respectively.  ...  Recent data from a multi-institution, randomized controlled clinical trial demonstrated that Magnetic Resonance-guided Focused Ultrasound (MRgFUS) thalamotomy improves upper limb tremor in medically refractory  ...  However, there is a move towards ultra-short echo time (UTE) magnetic resonance imaging to reduce patient exposure to ionizing radiation.  ... 
doi:10.1186/s40349-016-0076-5 fatcat:4vm7i5mt6vheni3hflxd3pwl2i

International Society for Therapeutic Ultrasound Conference 2016

Brian Fowlkes, Pejman Ghanouni, Narendra Sanghvi, Constantin Coussios, Paul C. Lyon, Michael Gray, Christophoros Mannaris, Marie de Saint Victor, Eleanor Stride, Robin Cleveland, Robert Carlisle, Feng Wu (+723 others)
2017 Journal of Therapeutic Ultrasound  
This may be currently associated with a high radiation dose.  ...  This may pose a challenge when treating an organ which comprises of several tissue types. Another challenge stems from the need for a high rate of image acquisition.  ...  protocols under magnetic resonance imaging (MRI) guidance.  ... 
doi:10.1186/s40349-016-0079-2 fatcat:wjrvxyhd5bappjipymenn5swwq

B - Scientific Sessions

2010 Insights into Imaging  
After image registration, perfusion was calculated with maximum slope technique; time-attenuation-curves and coloured perfusion maps were generated.  ...  Methods and Materials: 20 patients with clinically suspected severe acute pancreatitis were referred for CT evaluation and imaged with a 320-slice CT unit within the first 24 hours after admission.  ...  All MRI were performed on a 3 T MR system by using a 3D refocused radial imaging sequence with uTEs with the following parameters.  ... 
doi:10.1007/s13244-010-0011-1 pmid:23099631 pmcid:PMC3534347 fatcat:yfnq3lgteja2lfjl66ivdfnoum

Abstracts from the International Society for Therapeutic Ultrasound Conference 2017

2018 Journal of Therapeutic Ultrasound  
T2* map were created from multiecho gradient echo sequence at 3T (Achieva, Philips Healthcare, Andover, MA) through the rat brain with TE=7 msec, echo train length 5 and echo spacing 7 and Tr=1500 msec  ...  The purpose of this study was to evaluate the effects of multiple weekly courses of pFUS+MB exposures in the rat brain using micro-Positron Emmision Tomography (PET) and 18F-DPA-714, a marker of translocator  ...  Acknowledgements This work was supported by the Bettencourt Schueller Foundation and the "Agence Nationale de la Recherche" under the program "Future Investments" with the reference ANR-10-EQPX-15.  ... 
doi:10.1186/s40349-018-0110-x fatcat:4nn4nwntgbfl5cdwvqc3wfxszu

A Model for Online Interactive Remote Education for Medical Physics Using the Internet

Milton K Woo, Kwan-Hoong Ng
2003 Journal of Medical Internet Research  
short time.  ...  echo time, and a ramped tip angle.  ...  We used the imager to acquire real-time 512x480 radiographic frames of the phantom.  ... 
doi:10.2196/jmir.5.1.e3 pmid:12746208 pmcid:PMC1550549 fatcat:tsyf45yusza2jiglkq62rgo3qm

Noninvasive imaging

2001 Journal of the American College of Cardiology  
The purpose of this study was to analyze the LAA function with LAA clot and spontaneous echo contrast (SEC).  ...  There are not enough studies properly evaluating LAA function in a large number of patients (pts) with isolated severe MS.  ...  Magnetic resonance angiography was performed using a three-dimensional contrast-enhanced gradient echo technique with ultrashort echo time during breath-holding.  ... 
doi:10.1016/s0735-1097(01)80006-1 fatcat:ghklt3w3zze3le5gwnpbbfvrrm

The Following are Abstracts from the Second International Conference of the European Society for Molecular Imaging in Naples, Italy June 14-15, 2007

2007 Molecular Imaging  
Topics covered in this lecture include-but are not limited to-vascular and lymphatic targeting, molecular-genetic imaging, and other applications of toolkits of scientific and medical value.  ...  The aggregate data we have generated thus far indicate that a new targeted pharmacology and its ramifications are now unequivocally at hand.  ...  and fluorescence imaging of the sample with nanometric resolution (<50-100 nm), thus  ... 
doi:10.2310/7290.2007.00032 fatcat:hl2ynabt3bez7bt6vllibmsy3y

ECR 2011 Book of Abstracts - B - Scientific Sessions

2011 Insights into Imaging  
MR imaging was performed by 3D T1-weighted THRIVE breathold sequence (TR/ TE=3/1.57 msecs) before and after Gd-BOPTA injection (0.1 mmol/kg; 2 mL/sec) with contrast injection starting after contrast visualisation  ...  Purpose: To compare the HCC nodule conspicuity during the arterial phase between contrast-enhanced 64-row multidetector CT with bolus tracking and MR imaging with bolus chase.  ...  Purpose: The objective of this study was to apply magnetic resonance imaging (MRI) using displacement encoding with stimulated echoes (DENSE) to investigate the dynamic displacements and strain fields  ... 
doi:10.1007/s13244-011-0077-4 pmid:23100071 pmcid:PMC3533624 fatcat:lytbu2vohbhhnorjqlpogl77iu

Scientific Exhibits

2014 Journal of Medical Radiation Sciences  
Method: Six patients, three left-sided and three right-sided, treated with a 9 static field IMRT approach to a prescribed dose of 54 Gy in 30 fractions were selected for this study.  ...  The outcome of this study will lead to VMAT playing a vital role in the management of MPM, by reducing dose toxicity to OARs, increasing dose conformity to the PTV and reducing overall treatment times.  ...  Two new 3D isotropic sequences were tested; ultra short echo time (UTE) and point-wise encoding time reduction with radial acquisition (PETRA).  ... 
doi:10.1002/jmrs.74 pmid:27759942 pmcid:PMC4263487 fatcat:ccsk62gef5g47bfugrvtwqapj4

Athletic injuries of the extensor carpi ulnaris subsheath: MRI findings and utility of gadolinium-enhanced fat-saturated T1-weighted sequences with wrist pronation and supination

Jeremy Jeantroux, Fabio Becce, Henri Guerini, Bernard Montalvan, Dominique Le Viet, Jean-Luc Drapé
2010 European Radiology  
depiction of the 3D-magnetic resonance observation of cartilage repair tissue (MOCART) score.  ...  Pozzi Mucelli; Verona/ IT (gfoti81@yahoo.it) Purpose: To compare contrast-enhanced computed tomography (CECT), contrast-enhanced magnetic resonance imaging (MRI) and contrast-enhanced ultra-sonography  ...  and magnetic resonance imaging (MRI) using magnetic navigation.  ... 
doi:10.1007/s00330-010-1887-3 pmid:20680292 fatcat:c73xl4gmnjbp5hahuek6dg2pcu

SPR 2018

2018 Pediatric Radiology  
DISCLOSURES In compliance with ACCME requirements and guidelines, the ACR has developed a policy for review and disclosure of potential conflicts of interest, and a method of resolution if a conflict does  ...  CREDIT DESIGNATION STATEMENT: The American College of Radiology designates this activity for a maximum of 39. 25 AMA PRA Category 1 Credit(s) ™ Physicians should claim only the credit commensurate with  ...  echo time (UTE) imaging.  ... 
doi:10.1007/s00247-018-4130-z pmid:29707739 fatcat:46j635ave5hsldyl4phnftizsy

Posters

2011 Pediatric Radiology  
Purpose: Pneumonia is a common diagnosis amongst children admitted to hospital. Diagnosis relies upon accurate chest radiograph (CXR) interpretation.  ...  The same CXRs were then interpreted by 21 other paediatricians with varying experience levels.  ...  The Magnetic Resonance scanning was performed on a 3.0 Tesla imager.  ... 
doi:10.1007/s00247-011-2025-3 fatcat:4kgxnlpo2bes5phwdwsxu74j2y

ECR 2012 Book of Abstracts - A - Postergraduate Educational Programme

2012 Insights into Imaging  
Beside abdominal plain film and ultrasonography (US), computed tomography (CT) and magnetic resonance imaging (MRI) are two new and powerful imaging methods that have basically revolutionised the role  ...  Molecular imaging represents a group of integrated and complementary methods that evaluate the biological information resolved in time and space in vivo, at high resolution and by using with specific probes  ...  Scans and Magnetic Resonance.  ... 
doi:10.1007/s13244-012-0153-4 pmid:22696127 pmcid:PMC3481066 fatcat:te6ctbtakzh5njsw43geghw3ta

ECR 2015 Book of Abstracts - A - Postgraduate Educational Programme

2015 Insights into Imaging  
They are visible on T2* GRE which can be performed as 2D or 3D sequence. The size of the artefact depends on a number of imaging paramenters including the magnetic field strenght and echo time.  ...  magnetic resonance imaging will be discussed.  ...  With ultrashort time echo (UTE) sequences or variable echo time (VTE) sequences it is possible to acquire signal from those structures and to quantify it using T2* mapping.  ... 
doi:10.1007/s13244-015-0386-0 pmid:25708993 pmcid:PMC4349897 fatcat:m7eyvqcwojfpvf3lr5hy6dwjb4
« Previous Showing results 1 — 15 out of 38 results