Filters








1,788 Hits in 6.6 sec

Intermodality, retrospective image registration in the thorax

J N Yu, F H Fahey, H D Gage, C G Eades, B A Harkness, C A Pelizzari, J W Keyes
<span title="">1995</span> <i title="Society of Nuclear Medicine"> <a target="_blank" rel="noopener" href="https://fatcat.wiki/container/es34xtfdxrgybg2kmdq2n5xqry" style="color: black;">Journal of Nuclear Medicine</a> </i> &nbsp;
The purpose of this study was to develop an accurate, retrospectively applicable procedure for registering thoracic studies from different modalities in a short amount of time and with minimal operator  ...  We also thank Jim King and his staff in Abdominal CT at North Carolina Baptist Hospital for helping us retrieve patient CT data and acquiring the phantom study and Barry Wessels of George Washington University  ...  for the loan of the Alderson thoracic phantom.  ... 
<span class="external-identifiers"> <a target="_blank" rel="external noopener" href="https://www.ncbi.nlm.nih.gov/pubmed/8523127">pmid:8523127</a> <a target="_blank" rel="external noopener" href="https://fatcat.wiki/release/grswvuz66bdttg7xtdponsrxia">fatcat:grswvuz66bdttg7xtdponsrxia</a> </span>
<a target="_blank" rel="noopener" href="https://web.archive.org/web/20200319134108/http://jnm.snmjournals.org/content/36/12/2333.full.pdf" title="fulltext PDF download" data-goatcounter-click="serp-fulltext" data-goatcounter-title="serp-fulltext"> <button class="ui simple right pointing dropdown compact black labeled icon button serp-button"> <i class="icon ia-icon"></i> Web Archive [PDF] <div class="menu fulltext-thumbnail"> <img src="https://blobs.fatcat.wiki/thumbnail/pdf/07/a5/07a56d924ddd7e87096d1de4263fb367ca55fb89.180px.jpg" alt="fulltext thumbnail" loading="lazy"> </div> </button> </a>

2D Image Registration in CT Images Using Radial Image Descriptors [chapter]

Franz Graf, Hans-Peter Kriegel, Matthias Schubert, Sebastian Pölsterl, Alexander Cavallaro
<span title="">2011</span> <i title="Springer Berlin Heidelberg"> <a target="_blank" rel="noopener" href="https://fatcat.wiki/container/2w3awgokqne6te4nvlofavy5a4" style="color: black;">Lecture Notes in Computer Science</a> </i> &nbsp;
The experimental evaluation shows that the new method improves accuracy and stability of comparable registration methods by using only a a single CT slice is required for the registration.  ...  Registering CT scans in a body atlas is an important technique for aligning and comparing different CT scans.  ...  They are funded by the German Federal Ministry of Economics and Technology under the grant number 01MQ07020. The responsibility for this publication lies with the authors.  ... 
<span class="external-identifiers"> <a target="_blank" rel="external noopener noreferrer" href="https://doi.org/10.1007/978-3-642-23629-7_74">doi:10.1007/978-3-642-23629-7_74</a> <a target="_blank" rel="external noopener" href="https://fatcat.wiki/release/ftg4fcvaivalvnjzyeqacjnrsy">fatcat:ftg4fcvaivalvnjzyeqacjnrsy</a> </span>
<a target="_blank" rel="noopener" href="https://web.archive.org/web/20180729182219/https://link.springer.com/content/pdf/10.1007%2F978-3-642-23629-7_74.pdf" title="fulltext PDF download" data-goatcounter-click="serp-fulltext" data-goatcounter-title="serp-fulltext"> <button class="ui simple right pointing dropdown compact black labeled icon button serp-button"> <i class="icon ia-icon"></i> Web Archive [PDF] <div class="menu fulltext-thumbnail"> <img src="https://blobs.fatcat.wiki/thumbnail/pdf/c2/b7/c2b7f760fd514612f6b4fd96f85dcab6bfa88bb9.180px.jpg" alt="fulltext thumbnail" loading="lazy"> </div> </button> </a> <a target="_blank" rel="external noopener noreferrer" href="https://doi.org/10.1007/978-3-642-23629-7_74"> <button class="ui left aligned compact blue labeled icon button serp-button"> <i class="external alternate icon"></i> springer.com </button> </a>

An optical flow based method for improved reconstruction of 4D CT data sets acquired during free breathing

Jan Ehrhardt, René Werner, Dennis Säring, Thorsten Frenzel, Wei Lu, Daniel Low, Heinz Handels
<span title="2007-01-29">2007</span> <i title="Wiley"> <a target="_blank" rel="noopener" href="https://fatcat.wiki/container/4xxxfsh2pjc4nhsa3qijpqv6zy" style="color: black;">Medical Physics (Lancaster)</a> </i> &nbsp;
Modern CT scanners can only scan a limited region of the body simultaneously and patients have to be scanned in segments consisting of multiple slices.  ...  In this paper an optical flow based method for improved reconstruction of 4D CT data sets from multislice CT scans is presented.  ...  An optical flow based registration algorithm computes a velocity field describing the movement of corresponding features.  ... 
<span class="external-identifiers"> <a target="_blank" rel="external noopener noreferrer" href="https://doi.org/10.1118/1.2431245">doi:10.1118/1.2431245</a> <a target="_blank" rel="external noopener" href="https://www.ncbi.nlm.nih.gov/pubmed/17388189">pmid:17388189</a> <a target="_blank" rel="external noopener" href="https://fatcat.wiki/release/6aor2msqszftzg6owglmzipxu4">fatcat:6aor2msqszftzg6owglmzipxu4</a> </span>
<a target="_blank" rel="noopener" href="https://web.archive.org/web/20190302113335/http://pdfs.semanticscholar.org/a2a6/329c98b0481d41d395d49c0b829f87f0bc21.pdf" title="fulltext PDF download" data-goatcounter-click="serp-fulltext" data-goatcounter-title="serp-fulltext"> <button class="ui simple right pointing dropdown compact black labeled icon button serp-button"> <i class="icon ia-icon"></i> Web Archive [PDF] <div class="menu fulltext-thumbnail"> <img src="https://blobs.fatcat.wiki/thumbnail/pdf/a2/a6/a2a6329c98b0481d41d395d49c0b829f87f0bc21.180px.jpg" alt="fulltext thumbnail" loading="lazy"> </div> </button> </a> <a target="_blank" rel="external noopener noreferrer" href="https://doi.org/10.1118/1.2431245"> <button class="ui left aligned compact blue labeled icon button serp-button"> <i class="external alternate icon"></i> Publisher / doi.org </button> </a>

Automatic three-dimensional multimodality registration using radionuclide transmission CT attenuation maps: a phantom study

D Dey, P J Slomka, L J Hahn, R Kloiber
<span title="">1999</span> <i title="Society of Nuclear Medicine"> <a target="_blank" rel="noopener" href="https://fatcat.wiki/container/es34xtfdxrgybg2kmdq2n5xqry" style="color: black;">Journal of Nuclear Medicine</a> </i> &nbsp;
The purpose of this study was to evaluate, using a physical torso phantom, a novel, fully automated method for three-dimensional image registration of CT and SPECT, using radionuclide transmission (RNT  ...  Coregistration of images from a single subject, acquired by different modalities, is important in clinical diagnosis, surgery and therapy planning.  ...  Ian Cunningham for useful discussions regarding the CT data.  ... 
<span class="external-identifiers"> <a target="_blank" rel="external noopener" href="https://www.ncbi.nlm.nih.gov/pubmed/10086710">pmid:10086710</a> <a target="_blank" rel="external noopener" href="https://fatcat.wiki/release/gsvj44vw2jbpviifkwnuluzwl4">fatcat:gsvj44vw2jbpviifkwnuluzwl4</a> </span>
<a target="_blank" rel="noopener" href="https://web.archive.org/web/20200319130057/http://jnm.snmjournals.org/content/40/3/448.full.pdf" title="fulltext PDF download" data-goatcounter-click="serp-fulltext" data-goatcounter-title="serp-fulltext"> <button class="ui simple right pointing dropdown compact black labeled icon button serp-button"> <i class="icon ia-icon"></i> Web Archive [PDF] <div class="menu fulltext-thumbnail"> <img src="https://blobs.fatcat.wiki/thumbnail/pdf/d5/58/d558dc6a806ac8bbe4cb34a5f774b2aded31afc0.180px.jpg" alt="fulltext thumbnail" loading="lazy"> </div> </button> </a>

A review of cardiac image registration methods

T. Makela, P. Clarysse, O. Sipila, N. Pauna, Quoc Cuong Pham, T. Katila, I.E. Magnin
<span title="">2002</span> <i title="Institute of Electrical and Electronics Engineers (IEEE)"> <a target="_blank" rel="noopener" href="https://fatcat.wiki/container/yhnt2pif75h2bmnnmdg7m6nlc4" style="color: black;">IEEE Transactions on Medical Imaging</a> </i> &nbsp;
Automatic registration, based on computer programs, might, however, offer better accuracy and repeatability and save time.  ...  In this paper, the current status of cardiac image registration methods is reviewed.  ...  Registration Methods Based on Geometric Image Features Registration methods based on geometric image features can be divided into registration of a set of points and registration of edges or surfaces.  ... 
<span class="external-identifiers"> <a target="_blank" rel="external noopener noreferrer" href="https://doi.org/10.1109/tmi.2002.804441">doi:10.1109/tmi.2002.804441</a> <a target="_blank" rel="external noopener" href="https://www.ncbi.nlm.nih.gov/pubmed/12564869">pmid:12564869</a> <a target="_blank" rel="external noopener" href="https://fatcat.wiki/release/z6dx2vukqjbiplv6k5v4uz3xdq">fatcat:z6dx2vukqjbiplv6k5v4uz3xdq</a> </span>
<a target="_blank" rel="noopener" href="https://web.archive.org/web/20170809084540/http://read.pudn.com/downloads97/ebook/395821/A%20review%20of%20cardiac%20image%20registration%20methods.pdf" title="fulltext PDF download" data-goatcounter-click="serp-fulltext" data-goatcounter-title="serp-fulltext"> <button class="ui simple right pointing dropdown compact black labeled icon button serp-button"> <i class="icon ia-icon"></i> Web Archive [PDF] <div class="menu fulltext-thumbnail"> <img src="https://blobs.fatcat.wiki/thumbnail/pdf/4e/be/4ebe1ff8523b82b5cae087754dd996a64b63cca9.180px.jpg" alt="fulltext thumbnail" loading="lazy"> </div> </button> </a> <a target="_blank" rel="external noopener noreferrer" href="https://doi.org/10.1109/tmi.2002.804441"> <button class="ui left aligned compact blue labeled icon button serp-button"> <i class="external alternate icon"></i> ieee.com </button> </a>

Automatic 3D Registration of Lung Surfaces in Computed Tomography Scans [chapter]

Margrit Betke, Harrison Hong, Jane P. Ko
<span title="">2001</span> <i title="Springer Berlin Heidelberg"> <a target="_blank" rel="noopener" href="https://fatcat.wiki/container/2w3awgokqne6te4nvlofavy5a4" style="color: black;">Lecture Notes in Computer Science</a> </i> &nbsp;
We applied our method to register the 3D lung surfaces of 11 pairs of chest CT scans and report promising registration performance. 1  ...  We developed an automated system that registers chest CT scans temporally. Our registration method matches corresponding anatomical landmarks to obtain initial registration parameters.  ...  Correlation-Based Recognition of Anatomical Features.  ... 
<span class="external-identifiers"> <a target="_blank" rel="external noopener noreferrer" href="https://doi.org/10.1007/3-540-45468-3_87">doi:10.1007/3-540-45468-3_87</a> <a target="_blank" rel="external noopener" href="https://fatcat.wiki/release/xbboqxkwljg6xmuckuhrc7c2xq">fatcat:xbboqxkwljg6xmuckuhrc7c2xq</a> </span>
<a target="_blank" rel="noopener" href="https://web.archive.org/web/20050301101208/http://www.cs.bu.edu:80/techreports/pdf/2001-004-betke-hong-ko.pdf" title="fulltext PDF download" data-goatcounter-click="serp-fulltext" data-goatcounter-title="serp-fulltext"> <button class="ui simple right pointing dropdown compact black labeled icon button serp-button"> <i class="icon ia-icon"></i> Web Archive [PDF] <div class="menu fulltext-thumbnail"> <img src="https://blobs.fatcat.wiki/thumbnail/pdf/08/00/0800c2c84a38e5dbeeff65ce9804f984108fa0d7.180px.jpg" alt="fulltext thumbnail" loading="lazy"> </div> </button> </a> <a target="_blank" rel="external noopener noreferrer" href="https://doi.org/10.1007/3-540-45468-3_87"> <button class="ui left aligned compact blue labeled icon button serp-button"> <i class="external alternate icon"></i> springer.com </button> </a>

Automatic spatiotemporal matching of detected pleural thickenings

Kraisorn Chaisaowong, Simon Kai Keller, Thomas Kraus, Yulin Wang, Xudong Jiang, Ming Yang, David Zhang, Xie Yi
<span title="2014-01-10">2014</span> <i title="SPIE"> Fifth International Conference on Graphic and Image Processing (ICGIP 2013) </i> &nbsp;
In this work, automatic spatiotemporal matching techniques of the detected pleural thickenings at two points of time based on the semi-automatic registration have been developed, implemented, and tested  ...  As result, the application of the mapping technique using the principal components analysis turns out to be advantageous than the feature-based mapping using centroid and mean Hounsfield Units of each  ...  SEMI-AUTOMATIC RIGID REGISTRATION Registration of 2D images from CT image data.  ... 
<span class="external-identifiers"> <a target="_blank" rel="external noopener noreferrer" href="https://doi.org/10.1117/12.2049938">doi:10.1117/12.2049938</a> <a target="_blank" rel="external noopener" href="https://fatcat.wiki/release/6r7pjh22ebgdpcd3sebfb52usu">fatcat:6r7pjh22ebgdpcd3sebfb52usu</a> </span>
<a target="_blank" rel="noopener" href="https://web.archive.org/web/20170809030313/http://www.lfb.rwth-aachen.de/bibtexupload/pdf/CHA13c.pdf" title="fulltext PDF download" data-goatcounter-click="serp-fulltext" data-goatcounter-title="serp-fulltext"> <button class="ui simple right pointing dropdown compact black labeled icon button serp-button"> <i class="icon ia-icon"></i> Web Archive [PDF] <div class="menu fulltext-thumbnail"> <img src="https://blobs.fatcat.wiki/thumbnail/pdf/55/73/5573b176c0981f32aebcc3ebfb9ad0eed9586b1e.180px.jpg" alt="fulltext thumbnail" loading="lazy"> </div> </button> </a> <a target="_blank" rel="external noopener noreferrer" href="https://doi.org/10.1117/12.2049938"> <button class="ui left aligned compact blue labeled icon button serp-button"> <i class="external alternate icon"></i> Publisher / doi.org </button> </a>

Demonstration of accuracy and clinical versatility of mutual information for automatic multimodality image fusion using affine and thin-plate spline warped geometric deformations

Charles R. Meyer, Jennifer L. Boes, Boklye Kim, Peyton H. Bland, Kenneth R. Zasadny, Paul V. Kison, Kenneth Koral, Kirk A. Frey, Richard L. Wahl
<span title="">1997</span> <i title="Elsevier BV"> <a target="_blank" rel="noopener" href="https://fatcat.wiki/container/kpkfymbkufcnzjfc5ydyokby4y" style="color: black;">Medical Image Analysis</a> </i> &nbsp;
Quantitative registration errors were assessed in registrations of a thorax phantom using PET/CT and in the National Library of Medicine's Visible Male using MRI T2-/T1-weighted acquisitions.  ...  Registrations of diverse clinical data sets were demonstrated including rotate-translate mapping of PET/MRI brain scans with significant missing data, full affine mapping of thoracic PET/CT and rotate-translate  ...  All slices of the registration may be viewed on the CD-ROM. Table 1 . Difference in fiducial locations on PET and registered CT of the thorax phantom for each fiducial.  ... 
<span class="external-identifiers"> <a target="_blank" rel="external noopener noreferrer" href="https://doi.org/10.1016/s1361-8415(97)85010-4">doi:10.1016/s1361-8415(97)85010-4</a> <a target="_blank" rel="external noopener" href="https://www.ncbi.nlm.nih.gov/pubmed/9873906">pmid:9873906</a> <a target="_blank" rel="external noopener" href="https://fatcat.wiki/release/5bdb6iwwyfeb7ewn2hrlwp4hsm">fatcat:5bdb6iwwyfeb7ewn2hrlwp4hsm</a> </span>
<a target="_blank" rel="noopener" href="https://web.archive.org/web/20070723162723/http://www.dipl.rad.med.umich.edu/dipl/dipl-gallery/text/MIA1997/text.pdf" title="fulltext PDF download" data-goatcounter-click="serp-fulltext" data-goatcounter-title="serp-fulltext"> <button class="ui simple right pointing dropdown compact black labeled icon button serp-button"> <i class="icon ia-icon"></i> Web Archive [PDF] <div class="menu fulltext-thumbnail"> <img src="https://blobs.fatcat.wiki/thumbnail/pdf/08/c9/08c9354b8470d0916d5a1ae2a54e596361c58f59.180px.jpg" alt="fulltext thumbnail" loading="lazy"> </div> </button> </a> <a target="_blank" rel="external noopener noreferrer" href="https://doi.org/10.1016/s1361-8415(97)85010-4"> <button class="ui left aligned compact blue labeled icon button serp-button"> <i class="external alternate icon"></i> elsevier.com </button> </a>

Correction of motion effects in free breathing thoracic CT and PET imaging for radiotherapy [article]

Martin Skovmos Nielsen
<span title="">2016</span> <i title="Aalborg University Press"> <a target="_blank" rel="noopener" href="https://fatcat.wiki/container/m3ddwplh7bepjeye2yvjorv6b4" style="color: black;">The PhD Series of theThe PhD Series of the Faculty of Medicine</a> </i> &nbsp;
Declaration of interest: The authors report no confl icts of interest. The authors alone are responsible for the content and writing of the paper. Acknowledgements  ...  The CT slices selected for image registration were from the fi rst thoracic vertebra and 400 CT slices below covering 25 cm of the thorax including the total lung volume.  ...  This resampling of CT slices can be either amplitude-or phase-based.  ... 
<span class="external-identifiers"> <a target="_blank" rel="external noopener noreferrer" href="https://doi.org/10.5278/vbn.phd.med.00079">doi:10.5278/vbn.phd.med.00079</a> <a target="_blank" rel="external noopener" href="https://fatcat.wiki/release/w6ucxeilkzc3bawgrss5zs6xqi">fatcat:w6ucxeilkzc3bawgrss5zs6xqi</a> </span>
<a target="_blank" rel="noopener" href="https://web.archive.org/web/20200219021601/https://vbn.aau.dk/ws/files/316428419/PHD_Martin_SkovMos_Nielsen_E_pdf.pdf" title="fulltext PDF download" data-goatcounter-click="serp-fulltext" data-goatcounter-title="serp-fulltext"> <button class="ui simple right pointing dropdown compact black labeled icon button serp-button"> <i class="icon ia-icon"></i> Web Archive [PDF] <div class="menu fulltext-thumbnail"> <img src="https://blobs.fatcat.wiki/thumbnail/pdf/a6/75/a6758f1699b2dd032a3fe4041a551d37d0ab1ee1.180px.jpg" alt="fulltext thumbnail" loading="lazy"> </div> </button> </a> <a target="_blank" rel="external noopener noreferrer" href="https://doi.org/10.5278/vbn.phd.med.00079"> <button class="ui left aligned compact blue labeled icon button serp-button"> <i class="external alternate icon"></i> Publisher / doi.org </button> </a>

Reconstruction of 4D-CT data sets acquired during free breathing for the analysis of respiratory motion

Jan Ehrhardt, Rene Werner, Thorsten Frenzel, Dennis Säring, Wei Lu, Daniel Low, Heinz Handels, Joseph M. Reinhardt, Josien P. W. Pluim
<span title="2006-03-02">2006</span> <i title="SPIE"> <a target="_blank" rel="noopener" href="https://fatcat.wiki/container/ha25cznnjncxtjoykhsg6fz5ly" style="color: black;">Medical Imaging 2006: Image Processing</a> </i> &nbsp;
But modern CT scanners can only scan a limited region of the body simultaneously and patients have to be scanned in segments consisting of multiple slices.  ...  We present an optical flow based method for the reconstruction of 4D-CT data sets from multislice CT scans, which are collected simultaneously with digital spirometry.  ...  This process was repeated until the entire thorax was scanned.  ... 
<span class="external-identifiers"> <a target="_blank" rel="external noopener noreferrer" href="https://doi.org/10.1117/12.651730">doi:10.1117/12.651730</a> <a target="_blank" rel="external noopener" href="https://dblp.org/rec/conf/miip/EhrhardtWFSLLH06.html">dblp:conf/miip/EhrhardtWFSLLH06</a> <a target="_blank" rel="external noopener" href="https://fatcat.wiki/release/pihpnpoyu5bunnop6e3zlnng5u">fatcat:pihpnpoyu5bunnop6e3zlnng5u</a> </span>
<a target="_blank" rel="noopener" href="https://web.archive.org/web/20110924004826/http://www.uke.de/institute/medizinische-informatik/downloads/institut-medizinische-informatik/2006-Reconstruction__4DCT_Ehrhardt.pdf" title="fulltext PDF download" data-goatcounter-click="serp-fulltext" data-goatcounter-title="serp-fulltext"> <button class="ui simple right pointing dropdown compact black labeled icon button serp-button"> <i class="icon ia-icon"></i> Web Archive [PDF] <div class="menu fulltext-thumbnail"> <img src="https://blobs.fatcat.wiki/thumbnail/pdf/42/cc/42cc273c681f8fac366b14975a9986a70bfee35f.180px.jpg" alt="fulltext thumbnail" loading="lazy"> </div> </button> </a> <a target="_blank" rel="external noopener noreferrer" href="https://doi.org/10.1117/12.651730"> <button class="ui left aligned compact blue labeled icon button serp-button"> <i class="external alternate icon"></i> Publisher / doi.org </button> </a>

Thoracic and abdominal SPECT-CT image fusion without external markers in endocrine carcinomas. The Group of Thyroid Tumoral Pathology of Champagne-Ardenne

C Pérault, C Schvartz, H Wampach, J C Liehn, M J Delisle
<span title="">1997</span> <i title="Society of Nuclear Medicine"> <a target="_blank" rel="noopener" href="https://fatcat.wiki/container/es34xtfdxrgybg2kmdq2n5xqry" style="color: black;">Journal of Nuclear Medicine</a> </i> &nbsp;
Superimposition of SPECT and computed tomography (CT) slices from the thoracoabdominal region was achieved without the use of external markers for 14 studies in 13 patients with endocrine carcinoma.  ...  Technical feasibility and clinical validation of this retrospective fusion method were assessed.  ...  Chancy (University of North Carolina, Chapel Hill, NC) for his contributions to the final version of the manuscript.  ... 
<span class="external-identifiers"> <a target="_blank" rel="external noopener" href="https://www.ncbi.nlm.nih.gov/pubmed/9255157">pmid:9255157</a> <a target="_blank" rel="external noopener" href="https://fatcat.wiki/release/gurtwlerpvbczidmtvkchz35da">fatcat:gurtwlerpvbczidmtvkchz35da</a> </span>
<a target="_blank" rel="noopener" href="https://web.archive.org/web/20200318083116/http://jnm.snmjournals.org/content/38/8/1234.full.pdf" title="fulltext PDF download" data-goatcounter-click="serp-fulltext" data-goatcounter-title="serp-fulltext"> <button class="ui simple right pointing dropdown compact black labeled icon button serp-button"> <i class="icon ia-icon"></i> Web Archive [PDF] <div class="menu fulltext-thumbnail"> <img src="https://blobs.fatcat.wiki/thumbnail/pdf/19/6f/196fc0c2cbf9f5efc5fc3829cc7d718e1ce49fe4.180px.jpg" alt="fulltext thumbnail" loading="lazy"> </div> </button> </a>

Use of three-dimensional (3D) optical flow method in mapping 3D anatomic structure and tumor contours across four-dimensional computed tomography data

Geoffrey G Zhang, Tzung-Chi Huang, Thomas Guerrero, Kang-Ping Lin, Craig Stevens, George Starkschall, Ken Forster
<span title="2008-02-05">2008</span> <i title="Wiley (John Wiley &amp; Sons)"> <a target="_blank" rel="noopener" href="https://fatcat.wiki/container/tb6ytx3735fnnhyqltxc6yayym" style="color: black;">Journal of Applied Clinical Medical Physics</a> </i> &nbsp;
The 3D optical flow program is a good tool for anatomical structure and tumor volume contour mapping across 4D CT scans.  ...  The mapped contours of lungs, liver, esophagus, GTV, etc. in real patient 4D CT images were acceptable to clinicians.  ...  The multi-resolution feature implemented in the program is 3D, and thus it can start with fewer CT slices.  ... 
<span class="external-identifiers"> <a target="_blank" rel="external noopener" href="https://www.ncbi.nlm.nih.gov/pubmed/18449166">pmid:18449166</a> <a target="_blank" rel="external noopener" href="https://pubmed.ncbi.nlm.nih.gov/PMC5721534/">pmcid:PMC5721534</a> <a target="_blank" rel="external noopener" href="https://fatcat.wiki/release/rwgxpf563vg2rfooyuuwpnplay">fatcat:rwgxpf563vg2rfooyuuwpnplay</a> </span>
<a target="_blank" rel="noopener" href="https://web.archive.org/web/20191109231155/http://europepmc.org/backend/ptpmcrender.fcgi?accid=PMC5721534&amp;blobtype=pdf" title="fulltext PDF download" data-goatcounter-click="serp-fulltext" data-goatcounter-title="serp-fulltext"> <button class="ui simple right pointing dropdown compact black labeled icon button serp-button"> <i class="icon ia-icon"></i> Web Archive [PDF] <div class="menu fulltext-thumbnail"> <img src="https://blobs.fatcat.wiki/thumbnail/pdf/7c/aa/7caab732fbbb0bf26158f28b3d6f27f7c39e4d8a.180px.jpg" alt="fulltext thumbnail" loading="lazy"> </div> </button> </a> <a target="_blank" rel="external noopener" href="https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5721534" title="pubmed link"> <button class="ui compact blue labeled icon button serp-button"> <i class="file alternate outline icon"></i> pubmed.gov </button> </a>

Simulation of four-dimensional CT images from deformable registration between inhale and exhale breath-hold CT scans

David Sarrut, Vlad Boldea, Serge Miguet, Chantal Ginestet
<span title="2006-02-09">2006</span> <i title="Wiley"> <a target="_blank" rel="noopener" href="https://fatcat.wiki/container/4xxxfsh2pjc4nhsa3qijpqv6zy" style="color: black;">Medical Physics (Lancaster)</a> </i> &nbsp;
It is performed by deformable registration of two CT scans acquired at inhale and exhale breath-hold.  ...  Purpose: We propose to simulate an artificial four-dimensional ͑4-D͒ CT image of the thorax during breathing.  ...  We will only focus on studies using deformable registration between CT thorax images: inhale/exhale breath-hold CT images, 3-D images of a 4-D CT scan, images acquired at various moments during the treatment  ... 
<span class="external-identifiers"> <a target="_blank" rel="external noopener noreferrer" href="https://doi.org/10.1118/1.2161409">doi:10.1118/1.2161409</a> <a target="_blank" rel="external noopener" href="https://www.ncbi.nlm.nih.gov/pubmed/16878564">pmid:16878564</a> <a target="_blank" rel="external noopener" href="https://fatcat.wiki/release/dgaa5j2afnddlhzpzopcagva4e">fatcat:dgaa5j2afnddlhzpzopcagva4e</a> </span>
<a target="_blank" rel="noopener" href="https://web.archive.org/web/20170808133357/https://www.creatis.insa-lyon.fr/~dsarrut/articles/Sarrut2006c.pdf" title="fulltext PDF download" data-goatcounter-click="serp-fulltext" data-goatcounter-title="serp-fulltext"> <button class="ui simple right pointing dropdown compact black labeled icon button serp-button"> <i class="icon ia-icon"></i> Web Archive [PDF] <div class="menu fulltext-thumbnail"> <img src="https://blobs.fatcat.wiki/thumbnail/pdf/33/d4/33d4a58881fb74028328a232e255a0bd81b98c05.180px.jpg" alt="fulltext thumbnail" loading="lazy"> </div> </button> </a> <a target="_blank" rel="external noopener noreferrer" href="https://doi.org/10.1118/1.2161409"> <button class="ui left aligned compact blue labeled icon button serp-button"> <i class="external alternate icon"></i> Publisher / doi.org </button> </a>

Use of three-dimensional (3D) optical flow method in mapping 3D anatomic structure and tumor contours across four-dimensional computed tomography data

Geoffrey Zhang, Tzung-Chi Huang, Thomas Guerrero, Kang-Ping Lin, Craig Stevens, George Starkschall, Ken Forster
<span title="2008-02-05">2008</span> <i title="Wiley"> <a target="_blank" rel="noopener" href="https://fatcat.wiki/container/tb6ytx3735fnnhyqltxc6yayym" style="color: black;">Journal of Applied Clinical Medical Physics</a> </i> &nbsp;
The 3D optical flow program is a good tool for contour mapping of anatomic structure and tumor volume across 4D CT scans.  ...  The mapped contours in 4D CT images of lungs, liver, esophagus, GTV, and other structures for actual patients were acceptable to clinicians.  ...  The multi-resolution feature implemented in the program is 3D, and thus it can start with fewer CT slices.  ... 
<span class="external-identifiers"> <a target="_blank" rel="external noopener noreferrer" href="https://doi.org/10.1120/jacmp.v9i1.2738">doi:10.1120/jacmp.v9i1.2738</a> <a target="_blank" rel="external noopener" href="https://fatcat.wiki/release/2ftylmo44zf53npsryhep2jfwu">fatcat:2ftylmo44zf53npsryhep2jfwu</a> </span>
<a target="_blank" rel="noopener" href="https://web.archive.org/web/20191127232639/https://aapm.onlinelibrary.wiley.com/doi/pdfdirect/10.1120/jacmp.v9i1.2738" title="fulltext PDF download" data-goatcounter-click="serp-fulltext" data-goatcounter-title="serp-fulltext"> <button class="ui simple right pointing dropdown compact black labeled icon button serp-button"> <i class="icon ia-icon"></i> Web Archive [PDF] <div class="menu fulltext-thumbnail"> <img src="https://blobs.fatcat.wiki/thumbnail/pdf/45/e7/45e70bd03b0115c9a38baa4e09b9608f6b5841ba.180px.jpg" alt="fulltext thumbnail" loading="lazy"> </div> </button> </a> <a target="_blank" rel="external noopener noreferrer" href="https://doi.org/10.1120/jacmp.v9i1.2738"> <button class="ui left aligned compact blue labeled icon button serp-button"> <i class="unlock alternate icon" style="background-color: #fb971f;"></i> Publisher / doi.org </button> </a>

Validation of nonrigid registration in pretreatment and follow-up PET/CT scans for quantification of tumor residue in lung cancer patients

Jolanda Spijkerman, Davide Fontanarosa, Marco Das, Wouter van Elmpt
<span title="">2014</span> <i title="Wiley"> <a target="_blank" rel="noopener" href="https://fatcat.wiki/container/tb6ytx3735fnnhyqltxc6yayym" style="color: black;">Journal of Applied Clinical Medical Physics</a> </i> &nbsp;
Nonrigid registrations of pre-and postradiotherapy (RT) PET/CT scans of NSCLC patients were performed with different algorithms and validated tracking internal landmarks.  ...  Nonrigid registration significantly improves matching between pre-and post-RT CT scans for a subset of patients, although not in all patients.  ...  One of the authors (W.v.E.) would like to acknowledge funding (KWF MAC 2011-4970) from the Dutch Cancer Society. rEFErEncES  ... 
<span class="external-identifiers"> <a target="_blank" rel="external noopener noreferrer" href="https://doi.org/10.1120/jacmp.v15i4.4847">doi:10.1120/jacmp.v15i4.4847</a> <a target="_blank" rel="external noopener" href="https://www.ncbi.nlm.nih.gov/pubmed/25207414">pmid:25207414</a> <a target="_blank" rel="external noopener" href="https://pubmed.ncbi.nlm.nih.gov/PMC5875523/">pmcid:PMC5875523</a> <a target="_blank" rel="external noopener" href="https://fatcat.wiki/release/vu3waccmhvaydd3mhsphydy7ji">fatcat:vu3waccmhvaydd3mhsphydy7ji</a> </span>
<a target="_blank" rel="noopener" href="https://web.archive.org/web/20190302111757/http://pdfs.semanticscholar.org/b4bf/e78f000009b618bb6769025f51bdec9b2fa5.pdf" title="fulltext PDF download" data-goatcounter-click="serp-fulltext" data-goatcounter-title="serp-fulltext"> <button class="ui simple right pointing dropdown compact black labeled icon button serp-button"> <i class="icon ia-icon"></i> Web Archive [PDF] <div class="menu fulltext-thumbnail"> <img src="https://blobs.fatcat.wiki/thumbnail/pdf/b4/bf/b4bfe78f000009b618bb6769025f51bdec9b2fa5.180px.jpg" alt="fulltext thumbnail" loading="lazy"> </div> </button> </a> <a target="_blank" rel="external noopener noreferrer" href="https://doi.org/10.1120/jacmp.v15i4.4847"> <button class="ui left aligned compact blue labeled icon button serp-button"> <i class="unlock alternate icon" style="background-color: #fb971f;"></i> Publisher / doi.org </button> </a> <a target="_blank" rel="external noopener" href="https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5875523" title="pubmed link"> <button class="ui compact blue labeled icon button serp-button"> <i class="file alternate outline icon"></i> pubmed.gov </button> </a>
&laquo; Previous Showing results 1 &mdash; 15 out of 1,788 results