Filters








11 Hits in 18.2 sec

Evaluation of a color fused dual-band NVG

Maarten A. Hogervorst, Alexander Toet, Belur V. Dasarathy
2009 Multisensor, Multisource Information Fusion: Architectures, Algorithms, and Applications 2009  
We designed and evaluated a dual-band Night Vision Goggles sensor system.  ...  Our evaluation shows the added value of dual-band over single band NVG for the detection of targets, situational awareness, and perceived depth.  ...  Conclusions We have designed and evaluated a dual-band NVG system.  ... 
doi:10.1117/12.819114 fatcat:eqmf352n3fenpkqbesg5b3shfy

Real-Time Full Color Multiband Night Vision [chapter]

Alexander Toet, Maarten Hogervorst
2010 Vision Sensors and Edge Detection  
Performance for detecting targets was established for imagery of the dual-band fusion system, each of the individual NVG-bands (visual and NIR), standard NVG and daytime images (taken with a visual camera  ...  Visual (a), near-infrared (b) and the color fused dual-band image (c) for a scene including a blue target. The target is visible in the near-infrared band as a dark tube.  ... 
doi:10.5772/10136 fatcat:reb4kxgvx5awjmdglu6h7sr5ni

Cognitive Image Fusion and Assessment [chapter]

Alexander Toet
2011 Image Fusion  
Visual (a), NIR (b) and the color fused dual-band image (c) for a scene including a blue target. The target is visible in the NIR band as a dark tube.  ...  Field evaluations of dual-band fusion for color night vision, In: Enhanced and Synthetic Vision 1999, Verly, J.G. (Eds.),Vol.  ...  Publisher InTech Published online 12, January, 2011 Published in print edition January, 2011 Image fusion aims to generate a fused single image which contains more precise reliable visualization of the  ... 
doi:10.5772/14787 fatcat:lpmsn7hpabalngkqtcphdwgs4q

Performance history of AN/PVS-5 and ANVIS image intensification systems in U.S. Army aviation

William E. McLean, Clarence E. Rash, B. Joseph McEntire, Malcolm G. Braithwaite, John C. Mora, Ronald J. Lewandowski, Loran A. Haworth, Henry J. Girolamo
1997 Head-Mounted Displays II  
P43 also is yellow-green in color but is extremely narrow band (5 nm) and peaks at 543 nm. The persistence (10%) of P43 is 1.2 milliseconds, making it a medium-short persistence phosphor.  ...  The user could select either sensor, or the best of the two images could be fused into a composite.  ... 
doi:10.1117/12.276647 fatcat:lix5ei2lkfdbdn3vggf4rslxfq

Front Matter: Volume 7345

Proceedings of SPIE, Belur V. Dasarathy
2009 Multisensor, Multisource Information Fusion: Architectures, Algorithms, and Applications 2009  
A unique, consistent, permanent citation identifier (CID) number is assigned to each article at the time of the first publication.  ...  SPIE uses a six-digit CID article numbering system in which: The first four digits correspond to the SPIE volume number.  ...  Technology (United States) ix Introduction SESSION 1 LOW-LEVEL FUSION 7345 02 Evaluation of a color fused dual-band NVG [7345-02] M.  ... 
doi:10.1117/12.829107 fatcat:txli5vaqj5hunpybaxaadvki3e

Visual aids and eye protection for the aviator

1977 Applied Ergonomics  
ACKNOWLEDGEMENTS The authors gratefully acknowledge the valuable assistance and comments of our collegues D. DeSimone, R.J. Snyder Crew Systems Department and S.  ...  We have required that our aviators have normal color vision and a full field of vision. Yet, the narrowband output of the goggle eliminates color vision, and the gogg?.  ...  The fact that adequate spatial information is retained after the fiber optics twist is shown by the readily fused images presented to the eyes by the two tubes in the NVG.  ... 
doi:10.1016/0003-6870(77)90179-x fatcat:q4bz3dmgufgpzedu2byzwqr2jm

THE STUDY OF TECHNOLOGY TO BEAT THE DARK

Arthie, Nushrath Sameera, Afroz Begum, Sk
2018 Indian J.Sci.Res   unpublished
Image intensification gives a clear image, very good resolution, very good target identification probability.  ...  "Night Vision" is the technology that provides us with the miracle of vision in total darkness and the improvement of vision in low light environments.  ...  The high frequency band of the visible and IR images and low-frequency band of the visible and IR images are separately fused using minus operation.  ... 
fatcat:nisnydyb2rcdlmh4lhpwwpuwm4

Microscopic theory and numerical simulation of quantum well solar cells

Urs Aeberhard, Bernd Witzigmann, Fritz Henneberger, Yasuhiko Arakawa, Marek Osinski
2010 Physics and Simulation of Optoelectronic Devices XVIII  
Return to Contents Conference 7597: Physics and Simulation of Optoelectronic Devices XVIII the only loss mechanism in the cell.  ...  Both inverting and non-inverting configurations are being evaluated. Inverting tubes are being characterized in night vision goggle (NVG) and sights.  ...  the color mixing and the prediction of the color coordinates.  ... 
doi:10.1117/12.845478 fatcat:vxfg7swg3bh7rixxoa6qyhhx2u

SSC/SSCS Joint Annual Meeting 2018

2018 Cardiovascular Medicine  
Poster Walks (published in the online version of this issue) A 1 Poster Walk I. Pacemaker, defibrillator and electrophysiology A 5 Poster Walk I.  ...  Heart failure, vavulopathy and heart replacement therapy A 14 Poster Walk II. Cardiac imaging A 16 Poster Walk II. Clinical cases A 21 Poster Walk II. Congenital and pediatric cardiology A 24  ...  Results: Of 25 AFL (24 left and 1 right atrial, CL 261 ± 35 ms), 13 (52%) presented a dual-loop reentrant mechanism.  ... 
doi:10.4414/cvm.2018.00561 fatcat:2eq64o2uyvbs7mlecza47alvgu

2016 USAF Almanac CAPABILITY FOR A NEW GENERATION. ALMANAC 4 Editorial: Degrade, Dismantle, and Defeat

Adam Hebert
2016 unpublished
Carl A. Spaatz Sept. 26, 1947 April 29, 1948 Gen. Hoyt S. Vandenberg April 30, 1948 June 29, 1953 Gen. Nathan F. Twining June 30, 1953 Gen. Thomas D.  ...  Wayne A. Downing, USA May 20, 1993 Feb. 29, 1996 Gen. Henry H. Shelton, USA Feb. 29, 1996 Sept. 25, 1997 Gen. Peter J. Schoomaker, USA Nov. 5, 1997  ...  Mods include fully integrated INS/GPS systems, color LCDs, NVG lighting, HUDs, integrated defensive systems, digital moving map display, EO/ IR system, dual satcom for voice/data, enhanced cargo handling  ... 
fatcat:ipasot32xvclndq6xl4x7zleoa

NATO's air war for Kosovo: a strategic and operational assessment

2002 ChoiceReviews  
Daily counts of flexible targets known to have been hit in the KEZ were not kept, resulting in a large band of uncertainty with respect to estimates of kills of mobile targets.  ...  the rational employment of available in-theater assets and placed a premium on accurate information and the use of measures that took a disconcertingly long time to plan, carry out, and evaluate. 36 One  ...  His case that NATO won not because of but in spite of its chosen strategy is made in detail and exhaustively-and it is made well in a straightforward and highly readable style." Ivo H.  ... 
doi:10.5860/choice.40-0561 fatcat:i6zzmejz3vebzj4ak6jq4723qi