Filters








22 Hits in 8.6 sec

Feasibility of future epidemiological studies on possible health effects of mobile phone base stations

Georg Neubauer, Maria Feychting, Yngve Hamnerius, Leeka Kheifets, Niels Kuster, Ignacio Ruiz, Joachim Schüz, Richard Überbacher, Joe Wiart, Martin Röösli
2007 Bioelectromagnetics  
We also use a 3 µm X 3 µm membrane planar patch model with a Smoluchowski equation-based model to investigate local electroporation behavior due to pulses of a wide range of durations and amplitudes.  ...  The small, residual pores have lifetimes of order seconds, which is a mechanism for translating submicrosecond interactions to the physiological time scale of 0.1 ms to seconds.  ...  If the current directions of the two parallel-wise coils were same the solenoid coil could produce the effective fields.  ... 
doi:10.1002/bem.20298 pmid:17080459 fatcat:l23qxeq7cnh2xiz7yvfywdz5i4

Next-Generation Healthcare: Enabling Technologies for Emerging Bioelectromagnetics Applications

Asimina Kiourti, Amin M. Abbosh, Maria Athanasiou, Toni Bjorninen, Aline Eid, Cynthia Furse, Koichi Ito, Gianluca Lazzi, Mohamed Manoufali, Matteo Pastorino, Manos M. Tentzeris, Katrina Tisdale (+5 others)
2022 IEEE Open Journal of Antennas and Propagation  
This review paper provides a comprehensive overview, discusses challenges and opportunities, and indicates future directions for: (a) enabling technologies needed to make body area sensing and stimulation  ...  Rapid advances in antennas, propagation, electromagnetics, and materials are opening new and unexplored opportunities in body area sensing and stimulation.  ...  The metallization was approximately 1 μm thick with a conductivity of ~ 1 MS/m and hence was very similar to an embroidered thread.  ... 
doi:10.1109/ojap.2022.3162110 fatcat:q6qzm5qg5bb2hcb4ig6arbvsea

Compact Implantable Antennas for the Cerebrospinal Fluid Monitoring

Mohamed Manoufali, Konstanty Bialkowski, Beadaa Mohammed, Paul C. Mills, Amin Abbosh
2019 IEEE Transactions on Antennas and Propagation  
Following the severe impact of head tissues on the inductive coupling strength and the small antenna footprint for sensing DPs of CSF, several planar antennas are assessed for monitoring DPs through impedance  ...  The head tissues are extremely challenging for EM radiation compared to other body parts, which make the requirements for BIMDs to be rigorous in terms of the size, safety and sensitivity to changes in  ...  CSF case c Planar inverted-F antenna Table 7 7 .1 shows a comparison with other planar antennas operating in sub-1GHz band.  ... 
doi:10.1109/tap.2019.2896722 fatcat:6mtyxynlrbfovji7pqkdoamfju

Proceedings of the World Molecular Imaging Congress 2021, October 5-8, 2021: General Abstracts

2022 Molecular Imaging and Biology  
For most clinical MRI cases, the total number of iterations for enhanced image quality is around 8 with a total number of resolution subsets around 4.  ...  In general, the values of CNR reached a plateau at around 8 iterations with an average improvement factor of about 1.7 for processed MRI images.  ...  Acknowledgements: We acknowledge Center for Biomedical Neuroscience (CBN) 2020-21, UT Health San Antonio, Texas for generously providing funding for this research.  ... 
doi:10.1007/s11307-021-01693-y pmid:34982365 pmcid:PMC8725635 fatcat:4sfb3isoyfdhfbiwxfr55gvqym

Plenary lectures

2016 Current Topics in Biophysics  
The surface activity of AmB predisposes it for formation of monolayers at the air/water interface [3].  ...  It was concluded that the water-soluble self-associated forms of AmB are mainly responsible for being toxic to human erythrocytes.  ...  [ For studies related to the influence of magnetic field on the plant material was built field generator (solenoid) in the Department of Biophysics at the Faculty of Mathematics and Natural Sciences  ... 
doi:10.1515/ctb-20163-0002 fatcat:onjgzuylazgltiggbvzxgsw3ga

Completely wireless infrastructure for distributed mm-sized neural implants

Peilong Feng, Timothy Constandinou, Engineering And Physical Sciences Research Council
2020
Consequently, the microfabricated coil is selected as the receiving implantable coil, instead of wire-wound and CMOS coils, because of its excellent electrical properties and stable mechanical structure  ...  The emerging prospect of neural interfaces provides hope for these patients to regain their ability through treatment.  ...  Table 3 . 3 1: Comparison between planar spiral coil and solenoid.  ... 
doi:10.25560/80479 fatcat:fqb4d5gw4fb7hijgclng7ols34

Track I

2014 Biomedical Engineering  
These findings support the basic understanding of fs-lentotomy as a treatment method for presbyopia.  ...  The main goal of this paper is to examine echo state networks (ESN) for quantitative cell recognition.  ...  Acknowledgements The specifications for the selection field coil are provided by Gael Bringout (Institute of Medical Engineering, Universität zu Lübeck).  ... 
doi:10.1515/bmt-2014-5008 pmid:25385893 fatcat:4o7vqkhdmfgk5fjzqpeh74x5te

Proceedings of the World Molecular Imaging Congress 2020, October 7-9, 2020: General Abstracts

2022 Molecular Imaging and Biology  
Conclusion: Tumor specific uptake of pan800 provided remarkable contrast and a flexible imaging window for fluorescence-guided identification of HGGs despite modest EGFR expression.  ...  Therefore, in order to host a mouse, the commercially available relaxometer was modified with the implementation of a 40 mm 0.5T Field Cycling magnet and a dedicated 11mm solenoid detection coil placed  ...  Comparisons between control and Exo-SCy5 groups were performed by using Student's t test, after checking for normality.  ... 
doi:10.1007/s11307-021-01691-0 pmid:34982363 pmcid:PMC8725637 fatcat:ipn7hwekzzh6nbsk6dr2mzuhhm

Ecological study on the penetration of induction heating cookers and birth outcomes in Japan

Yasuto Sato, 1 Department of Public Health, School of Medicine, Tokyo Women's Medical University, 8-1 Kawada-cho, Shinjuku-ku, Tokyo 162-8666, Japan, Kosuke Kiyohara, Sachiko Takehara, Noriko Kojimahara, 2 Department of Food Science, Faculty of Home Economics, Otsuma Women's University, 12 Sanban-cho, Chiyoda-ku, Tokyo 102-8357, Japan
2020 AIMS Public Health  
We created data sets for all 47 prefectures in Japan using previously published statistics.  ...  The present study was conducted with the aim of analyzing whether there is a relationship between the penetration of induction heating cookers and birth outcomes using an ecological study design at the  ...  For open MR scanners with the static field vertical, the RF B 1 field is often produced by a pair of planar coils placed above and below the patient.  ... 
doi:10.3934/publichealth.2020028 pmid:32617360 pmcid:PMC7327398 fatcat:2x6njx5oq5ha7f2hxbriuorzum

Seventh International Conference

Colin Murray Parkes, Rosie Dalzell, Mike Pearson, Martin Newman
2005 Bereavement Care  
The reconstruction of the mechanical source can also be used as an estimate of the point spread function for designing US beamformer for US imaging, controlling tissue deformation (i.e., elasticity imaging  ...  Palmeri for their technical communication on shear velocity estimation using ARFI.  ...  The solenoid consisted of an iron core to focus the magnetic field within the region of interest.  ... 
doi:10.1080/02682620508657640 fatcat:hwoqd64zz5b6bkhpyteeazib5u

A design methodology for 2D sparse NDE arrays using an efficient implementation of refracted-ray TFM

Jerzy Dziewierz, Timothy Lardner, Anthony Gachagan
2013 2013 IEEE International Ultrasonics Symposium (IUS)  
Using this technology, the spatial patterning of cells can be controlled noninvasively through proper design of the ultrasound field.  ...  Recent advances in the field of tissue engineering include the engineering of skin, cartilage, and bladder, all of which are relatively thin tissues that can rely on diffusion for the delivery of oxygen  ...  The authors acknowledge the ANR and DGA for their support under the project Metactif, grant ANR-11-ASTR-015.  ... 
doi:10.1109/ultsym.2013.0035 fatcat:th5znfh7y5bklfdbmhb4u6iq2i

Power pulsing of the CALICE tile hadron calorimeter

Mathias Reinecke
2016 2016 IEEE Nuclear Science Symposium, Medical Imaging Conference and Room-Temperature Semiconductor Detector Workshop (NSS/MIC/RTSD)  
For example, we now know that neutrinos have a mass, providing clear evidence for physics beyond the our current understanding.  ...  This achievement was recognised through the award of the 2015 Nobel prize for physics to the leaders of the SNO and Super-Kamiokande experiments for the conclusive establishment of the phenomenon of neutrino  ...  extents their application field.  ... 
doi:10.1109/nssmic.2016.8069748 fatcat:zjgd7dmfdbhntb4kfwdtrlejhi

Understanding Smart Sensors

Randy Frank
2000 Measurement science and technology  
Vs 4.  ...  Polyimide is used as the dielectric interlayer between for embedding the coils and the cores. Figure 9 .3 shows the functional micromotor and an example of the meander coil [5, 6] .  ...  field and to remain polarized after the field is removed fieldbus a two-way communications link among intelligent field devices and control systems devices semiconductor memory that can be used for permanent  ... 
doi:10.1088/0957-0233/11/12/711 fatcat:inet5t3lzbecrczd2f5tdevkzq

Design and performance study of implantable and ingestible antennas [article]

Maria Riga, National Technological University Of Athens, National Technological University Of Athens
2017
Mom, this song, like all of this, this song is for you.  ...  Νikita, for her trust and support all along this thesis. A special thank you goes to my wonderful parents for standing next to me, with constant support and encouragement.  ...  The RFID tag was a subminiature glass capsule containing a solenoidal coil and an integrated circuit, used for livestock, pet, laboratory animal, and endangered-species identification.  ... 
doi:10.26240/heal.ntua.14479 fatcat:fertlgtxefeqjmp43cz4va4kx4

Effect of MR contrast agents on quantitative accuracy of PET in combined whole-body PET/MR imaging

Cristina Lois, Ilja Bezrukov, Holger Schmidt, Nina Schwenzer, Matthias K. Werner, Jürgen Kupferschläger, Thomas Beyer
2012 European Journal of Nuclear Medicine and Molecular Imaging  
MacDonald, University of Washington, USA MIC15.S-239 RF Coil Design for Low and High Field MRI: Numerical Methods and Measurements R. Stara 1 , N. Fontana 1 , A. Monorchio 1 , G. Manara 1 , A.  ...  Nuyts, K.U.Leuven, Belgium MIC18.M-18 A 55μmx55μm Charge-Integration Digital Pixel Sensor for Digital Direct Mammography in 0.18μm CMOS Technology R. Figueras, L. Teres, F.  ...  for those wishing to take advantage of the Disney parks.  ... 
doi:10.1007/s00259-012-2190-0 pmid:22890801 fatcat:gaikvxa6hrc2xobeyxp7gyu3ha
« Previous Showing results 1 — 15 out of 22 results