A copy of this work was available on the public web and has been preserved in the Wayback Machine. The capture dates from 2017; you can also visit the original URL.
The file type is application/pdf
.
Filters
Detection and regulation of CCFL current and open-lamp voltage while keeping floating condition of the lamp
2006
IEEE transactions on industrial electronics (1982. Print)
707 efficiency of the original two-stage converter with ZVT circuitry (B1) and that of the new devices without the soft-switching circuitry (B2) at the maximum output power and for the whole input voltage ...
All these improvements are achieved with no converter performance reduction as regards EMI and lowfrequency harmonic regulations. The main drawback of the SiC diodes is its price. ...
Detection and Regulation of CCFL Current and Open-Lamp Voltage While Keeping Floating Condition of the Lamp Sang Kyung Kim, Hee Seok Han, Young Jin Woo, and Gyu Hyeong Cho Abstract-A new simple balanced ...
doi:10.1109/tie.2006.870883
fatcat:4qyalquaazawtaal7nlgmou3ay
Resonant Behaviour of Pulse Generators for the Efficient Drive of Optical Radiation Sources Based on Dielectric Barrier Discharges
2013
A flat DBD lamp with a capacitance of 3.18 nF and an ignition voltage of 2 kV was operated with a pulse frequency of more than 1 MHz while a smaller experimental coaxial DBD was operated at 3.1 MHz. ...
The novel topologies introduced are based on pure resonant operation or a combination of resonant operation and inductor pre-charge which offers an improved adaptability to different lamps and higher voltage ...
Related topics are pure electrical ignition detection, DBD power measurement, ensuring ZVS condition under changing load conditions and self-optimising energy recovery. ...
doi:10.5445/ksp/1000036098
fatcat:l32yku6d4jf3vjxk2uttx2nixy