Filters








237,202 Hits in 2.7 sec

Master-Slave based test cost reduction method for DNN Accelerators

Umair Saeed Solangi, Muhammad Ibtesam, Sungju Park
2021 IEICE Electronics Express  
To achieve reduction in test time of accelerators, broadcasting of test patterns is used for simultaneous testing of processing elements (PEs).  ...  However, number of PEs tested simultaneously is limited because of scan shift power constraint.  ...  For this, parallel connections among respective scan FFs are made, this connection is called scan-connection. Slaves are scan-connected with Master and neighboring Slave.  ... 
doi:10.1587/elex.18.20210425 fatcat:nr2xvuf6pvgxlcfrlugs6glww4

Deep learning-based reconstruction of highly accelerated 3D MRI [article]

Sangtae Ahn, Uri Wollner, Graeme McKinnon, Isabelle Heukensfeldt Jansen, Rafi Brada, Dan Rettmann, Ty A. Cashen, John Huston, J. Kevin DeMarco, Robert Y. Shih, Joshua D. Trzasko, Christopher J. Hardy (+1 others)
2022 arXiv   pre-print
with dense skip-layer connections, was trained on 3D T1-weighted brain scan data to reconstruct complex-valued images from highly-undersampled k-space data.  ...  Conclusion: DL-Speed was shown to accelerate 3D MPRAGE and LAVA with up to a net 10-fold acceleration, achieving 2-5 times faster scans compared to conventional parallel imaging and acceleration, while  ...  Estimated navigated scan times for the standard regular-sampling scan with a 3.8-fold acceleration and the VDPD sampling scan with a 9.3-fold acceleration were 41.7 s and 16.4 s, respectively.  ... 
arXiv:2203.04674v1 fatcat:w3hzgorkt5dkhmygfosaw3xcfe

Co-Emulation of Scan-Chain Based Designs Utilizing SCE-MI Infrastructure [article]

Bill Jason Tomas, Yingtao Jiang, Mei Yang
2014 arXiv   pre-print
In addition, the integration of scan testing and acceleration/emulation platforms allows more complex DFT methods to be developed and tested on a large scale system, decreasing the time to market for products  ...  As the complexity of the scan algorithm is dependent on the number of design registers, large SoC scan designs can no longer be verified in RTL simulation unless partitioned into smaller sub-blocks.  ...  After connecting the scripts to the design directory, the simulation acceleration is run.  ... 
arXiv:1409.3276v1 fatcat:ta7ephokofh25cfesgljk2x22a

Adaptive 3D Imaging and Tolerance Analysis of Prefabricated Components for Accelerated Construction

Vamsi Sai Kalasapudi, Pingbo Tang, Chengyi Zhang, Jose Diosdado, Ram Ganapathy
2015 Procedia Engineering  
Tolerance analysis of prefabricated components poses challenges to effective quality control of accelerated construction projects in urban areas.  ...  Accelerated constructions also bring challenges of "fit-up:" misalignments between components can occur due to less detailed tolerance assessments of components.  ...  To address these concerns, many accelerated construction methods use prefabricated co mponents to reduce the field operation t ime.  ... 
doi:10.1016/j.proeng.2015.08.549 fatcat:mp6kaivzbjg2vgowd4dad55zcu

Co-Emulation of Scan-Chain Based Designs Utilizing SCE-MI Infrastructure

Bill Jason Tomas, Yingtao Jiang, Mei Yang
2014 International Journal of Computer Science & Information Technology (IJCSIT)  
Scan-chain is a design-for-test (DFT) methodology used for testing digital circuits.  ...  More so, as the complexity of the scan algorithm is dependent on the number of design registers, large SoC scan designs can no longer be verified in RTL simulation unless portioned into smaller sub-blocks  ...  After connecting the scripts to the design directory, the simulation acceleration is run.  ... 
doi:10.5121/ijcsit.2014.6406 fatcat:ryxoy6fasfax3nsvrbnxca6e4e

High resolution whole brain diffusion imaging at 7 T for the Human Connectome Project

A.T. Vu, E. Auerbach, C. Lenglet, S. Moeller, S.N. Sotiropoulos, S. Jbabdi, J. Andersson, E. Yacoub, K. Ugurbil
2015 NeuroImage  
Mapping structural connectivity in healthy adults for the Human Connectome Project (HCP) benefits from high quality, high resolution, multiband (MB)-accelerated whole brain diffusion MRI (dMRI).  ...  Note, when slice acceleration is used alone (without in-plane acceleration), a single-band GRE reference scan is not necessary .  ...  Page 24 Evaluation of in-plane acceleration reference scan. A) iPAT=3 MB=3 0.9 mm example GE EPI images.  ... 
doi:10.1016/j.neuroimage.2015.08.004 pmid:26260428 pmcid:PMC4618066 fatcat:axwozhp52jfxpparq4ozjpjzmu

IMPROVED BURNING DOWN PROTECTION SYSTEM OF INDUSTRIAL ELECTRON ACCELERATORS OUTLET WINDOW FOIL

S.O. Bandurov, R.S. Lozhkin, G.О. Shishkin
2019 Problems of Atomic Science and Technology  
The proposed protection system on current windings of horizontal and vertical sweeps can be applied in industrial accelerators of the ELV-1 series.  ...  The results of the industrial electron accelerators protection system deficiencies analysis in the event of emer-gency conditions are given and the ways to improve it are suggested in the article.  ...  Dubiaga and Head of the charged particles accelerator section V.G. Radchenko for the help in working to improve the electron accelerators as part of the writing of this work.  ... 
doi:10.46813/2019-122-169 fatcat:63wng2wnavdf5gfjzesoliai7m

Real-time single-pass connected components analysis algorithm

Fei Zhao, Huan zhang Lu, Zhi yong Zhang
2013 EURASIP Journal on Image and Video Processing  
Equivalence is resolved when the image is scanning, without extra processing time.  ...  Experimental results indicate that the hardware acceleration of algorithm achieves real-time CCA in RTATR system.  ...  Centralized operations become the bottleneck of hardware acceleration.  ... 
doi:10.1186/1687-5281-2013-21 fatcat:dqpzynncjnaalmaufczyldiuhy

Design of a Vibration Detection Terminal

Guoshao Chen, Fei Xu
2019 International Journal of Advanced Network, Monitoring, and Controls  
When a vehicle passes by, the spring switch wakes up the CPU and the acceleration sensor to collect data.  ...  In order to reduce the overall power consumption of the terminal, which use two sensors, one is spring switch and another is acceleration sensor.  ...  Channel scanning process It includes two processes: energy scanning and active scanning.  ... 
doi:10.21307/ijanmc-2019-060 fatcat:46wqfw4fi5abzjnc4v23cvtx4q

Test Architecture for Systolic Array of Edge-based AI Accelerator

Umair Saeed Solangi, Muhammad Ibtesam, Muhammad Adil Ansari, Jinuk Kim, Sungju Park
2021 IEEE Access  
In this paper, a novel test architecture based on selective-partial scan is proposed for performance, power and area (PPA) overhead constrained edge-based systolic AI accelerator.  ...  However, it may not yield an optimal test solution with stringent design constraints of edge-based AI accelerators.  ...  On the other hand, the accelerators with spatial connection, like systolic array, the connectivity between neighboring cells requires much less energy and low bandwidth [12] - [14] .  ... 
doi:10.1109/access.2021.3094741 fatcat:jdrlhnxsijgg3kwggpj2o5dc7u

Synchronous Measurement of Acceleration by MEMS Sensors Over CAN Bus

Martin Juránek, Jiří Kulhánek
2011 Transactions of the VSB : Technical University of Ostrava  
This paper discusses possibility of synchronous measurements of acceleration by digital MEMs sensors with the use of the CAN bus.  ...  We verified by measurements, that digital MEMs sensors can be synchronized over the CAN bus, with respect to theirs typical scanning frequency.  ...  The principle of acceleration measurement is capacitive (see Fig 2) .  ... 
doi:10.22223/tr.2011-2/1873 fatcat:7ifjmauj25afjgx6hp7xddox5a

The scanning microbeam PIXE analysis facility at NIRS

Hitoshi Imaseki, Masae Yukawa, Frank Watt, Takahiro Ishikawa, Hiroyuki Iso, Tsuyoshi Hamano, Kenichi Matsumoto, Nakahiro Yasuda
2003 Nuclear Instruments and Methods in Physics Reseach B  
The result of beam resolution tests carried out in 2001 are as follows: for scanning transmission ion microscopy, the estimated beam size is 100 Â 200 nm, measured using a 2.6 MeV proton beam scanned over  ...  The specifications of the Tandetron accelerator system operating at NIRS are as follows: the accelerating voltage is 0.4-1.7 MV, and the maximum beam current is 500 nA at 3.4 MeV.  ...  For this purpose, we have started the construction of a new microbeam irradiation facility (named as SPICE) which will be connected to our Tandem accelerator (3.4 MeV 2 H þ and 5.1 MeV 4 He 2þ ).  ... 
doi:10.1016/s0168-583x(03)01002-4 fatcat:bga4vbwvrjfczbkvhduuwktlfa

The Design of Large Scale IP Address and Port Scanning Tool

Chao Yuan, Jinze Du, Min Yue, Tao Ma
2020 Sensors  
This article uses Go Concurrency Patterns, combined with transmission control protocol (TCP) full connection scanning and GIMP Toolkit (GTK) graphic display technology, to develop a tool called HIRFL Scanner  ...  It is of great importance to maintain the accelerator system's network security for the stable operation of the accelerator.  ...  We scanned each port of all devices in the accelerator experiment. A total of 912 million ports of 13,915 devices were scanned. For Nmap, we choose T5 and sS parameters to accelerate scanning.  ... 
doi:10.3390/s20164423 pmid:32784387 fatcat:pii6lz5g3jbffmfog25yp76dqy

Memory-Access-Driven Context Partitioning for Window-Based Image Processing on Heterogeneous Multicore Processors

Hasitha Muthumala WAIDYASOORIYA, Yosuke OHBAYASHI, Masanori HARIYAMA, Michitaka KAMEYAMA
2012 IEICE transactions on information and systems  
Accelerator cores in low-power heterogeneous processors have on-chip local memories to enable parallel data access. The memory capacities of the local memories are very small.  ...  It has 4 CPU cores and 2 FE-GA (Flexible Engine/Generic ALU Arrays) accelerator cores. All the cores are connected through a bus called "Super-Hyway".  ...  An off-chip SDRAM is connected to the processor through the SuperHyway. Figure 9 shows the architecture of the FE-GA accelerator. It has an array of 32 PEs called "ALU" cells and "MLT" cells.  ... 
doi:10.1587/transinf.e95.d.354 fatcat:zokcwd4kc5fwxb6ca2fwxv7rmi

A Metal Impregnation Method of Biological Specimens for Scanning Electron Microscopy

Takuro MURAKAMI
1973 Archivum histologicum japonicum  
Undesirable charging effect was inconspicuous when accelerating voltage 5-25kV was used. A scanning image of the renal glomerulus was shown and the details of the method were described.  ...  Blocks of the kidney and other organs of the guinea pig fixed with glutaraldehyde and treated with tannic acid and osmium tetroxide could, without any coating, be observed in the scanning electron microscope  ...  It is now being attempted in our laboratory to reveal the mode of connection between the arterioles and sinuses within the spleen by microdissecting them in the scanning electron microscope.  ... 
doi:10.1679/aohc1950.35.323 fatcat:rgfn5skvhzah5gcn44fbkf6pya
« Previous Showing results 1 — 15 out of 237,202 results