A copy of this work was available on the public web and has been preserved in the Wayback Machine. The capture dates from 2021; you can also visit the original URL.
The file type is application/pdf
.
Filters
Design and Application of Biomedical Circuits and Systems
2020
Electronics
The development of new sensing technologies, biomaterials, microelectronic devices, microfluidic systems and micro-electro-mechanical systems (MEMs) etc [...] ...
Conflicts of Interest: The authors declare no conflict of interest. ...
for proper and accurate data acquisition tasks. ...
doi:10.3390/electronics9111920
fatcat:2tre5tkeanfzzbxx3uvdmzbeji
A Wearable Smart Device to Monitor Multiple Vital Parameters—VITAL ECG
2020
Electronics
This paper presents the second generation of VITAL-ECG, a smart device designed to monitor the most important vital parameters as a "one touch" device, anywhere, at low cost. ...
Smart devices are more and more present in every aspect of everyday life. ...
Acknowledgments: A special thanks to Federico Caffarelli and Giacomo Zanichelli.
Conflicts of Interest: The authors declare no conflict of interest. ...
doi:10.3390/electronics9020300
fatcat:t62qcxmhgbgm3lj76huy7o5p2a
Multichannel ECG recording from waist using textile sensors
2020
BioMedical Engineering OnLine
Monitoring heart health and its conditions such as ventricular disturbances and arrhythmias can be achieved through evaluating various features of ECG such as R-peaks, QRS complex, T-wave, and P-wave. ...
In this paper, we develop a textile-based multichannel ECG band that has the ability to measure ECG from multiple locations on the waist. ...
Acknowledgements We acknowledge Myant Inc. for providing all textile materials and the waist band for the present study. ...
doi:10.1186/s12938-020-00788-x
pmid:32546233
pmcid:PMC7296680
fatcat:msptejo7ybcdhlc4bqkadipi2a
Toward the Use of Temporary Tattoo Electrodes for Impedancemetric Respiration Monitoring and Other Electrophysiological Recordings on Skin
2021
Sensors
Ag ink and magnetic interlink, that guarantees a repositionable, long-term stable and robust interconnection of TTEs with external "docking" devices. ...
In this work, we present a TTEs epidermal sensor for real time monitoring of respiration through transthoracic impedance measurements, exploiting a new design, based on the application of soft screen printed ...
Conflicts of Interest: The authors declare no conflict of interest. Sensors 2021, 21, 1197 ...
doi:10.3390/s21041197
pmid:33567724
pmcid:PMC7915056
fatcat:rbowekn6gvbgrhpbv3ivrzhtda
Biomedical Signal Acquisition Using Sensors under the Paradigm of Parallel Computing
2020
Sensors
EEG data-processing applications have been used in neuroscience research to be highly computing- and data-intensive. ...
of a great variety of therapies. ...
Conflicts of Interest: The authors declare no conflict of interest. ...
doi:10.3390/s20236991
pmid:33297388
fatcat:4ow7epfi2zdetgqe3u7ot4sioq
Arterial Aging Best Reflected in Pulse Wave Velocity Measured from Neck to Lower Limbs: A Whole-Body Multichannel Bioimpedance Study
2022
Sensors
The main goal of this study was to establish a methodology to test and validate multichannel bioimpedance as a suitable method for whole-body evaluations of pulse waves. (2) Methods: We set the proximal ...
Data were acquired from a statistical group of 220 healthy subjects who were divided into three age groups. ...
The funders had no role in the design of the study; in the collection, analyses, or interpretation of data; in the writing of the manuscript; or in the decision to publish the results. ...
doi:10.3390/s22051910
pmid:35271057
pmcid:PMC8915004
fatcat:vtzl5umbhbbz7iyr4o3szkgmkq
Assessment of OMT-28, a synthetic analog of omega-3 epoxyeicosanoids, in patients with persistent atrial fibrillation: Rationale and design of the PROMISE-AF phase II study
2020
International Journal of Cardiology: Heart & Vasculature
Recruitment started in March 2019 and the study will include a total of 120 patients. ...
The PROMISE-AF study (NCT03906799) is designed to assess the efficacy (primary objective), safety, and population pharmacokinetics (secondary objectives) of three different doses of OMT-28, administered ...
Acknowledgment We acknowledge the contributions and continuous support by. ...
doi:10.1016/j.ijcha.2020.100573
pmid:32685659
pmcid:PMC7356118
fatcat:5ntx4dtl5veypoeh3ck2dwqk2q
A Comprehensive Review on Seismocardiogram: Current Advancements on Acquisition, Annotation, and Applications
2021
Mathematics
Therefore, providing new and reliable data regarding advancements in the field of SCG, i.e., new devices and tools, is necessary to outperform the current understanding of the State-of-the-Art (SoTA). ...
Cardiac vibrations yield a wide and rich spectrum of essential information regarding the functioning of the heart, and thus it is necessary to take advantage of this data to better monitor cardiac health ...
Data Availability Statement: Not applicable.
Conflicts of Interest: The authors declare no conflict of interest. ...
doi:10.3390/math9182243
fatcat:uiwrndfe3jdgvebrvxdclrxg3q
Medical-Grade ECG Sensor for Long-Term Monitoring
2020
Sensors
The sensor has been certified as a class IIa medical device and is available on the market under the trademark Savvy ECG. ...
With appropriate placement of the device on the chest, a very clear distinction of all electrocardiographic waves can be achieved, allowing for ECG recording of high quality, sufficient for medical analysis ...
Today, a wide range of ECG devices are used in medicine: 12-lead ECG, multichannel ECG (MECG), Holter monitor, implantable loop recorder (ILR), and some others. ...
doi:10.3390/s20061695
pmid:32197444
fatcat:r5lqw2tekjeizecrxywqczv25m
A CMOS analog front-end IC for portable EEG/ECG monitoring applications
2005
IEEE Transactions on Circuits and Systems I Fundamental Theory and Applications
Wang and X. P. Fan for allowing their EEG signals to be recorded. They also want to express their gratitude to Prof. L. M. Goh for advice during the EEG recording sessions. ...
CONCLUSION The design of a CMOS AFE IC for portable biomedical signal acquisition applications is presented. ...
The proposed AFE IC is based on a partition design approach.
III. DESIGN AND IMPLEMENTATION OF PROPOSED AFE
A. ...
doi:10.1109/tcsi.2005.854141
fatcat:cymlop3zlfh7xf5cf3t3vtp6vu
Development of a Finger-Ring-Shaped Hybrid Smart Stethoscope for Automatic S1 and S2 Heart Sound Identification
2021
Sensors
The device was designed with a folding finger-ring shape that can be worn on the finger and placed on the chest to measure photoplethysmogram (PPG) signals and acquire the heart sound simultaneously. ...
In addition, within the developed algorithm, the device was as accurate in start-points of heart sound detection as professional physiological signal-acquisition systems. ...
A Holter monitor is one of the most popular professional ECG acquisition devices, featuring a dozen electrodes that attach to the surface of the user's chest and record ECG variation over a 24 h period ...
doi:10.3390/s21186294
pmid:34577501
fatcat:sl5mgqvlm5fyhcidlugq7oe7hq
Implementation of Artifact Detection in Critical Care: A Methodological Review
2013
IEEE Reviews in Biomedical Engineering
Review results show that most published algorithms: (a) are designed for one specific type of CCU; (b) are validated on data harvested only from one Original Equipment Manufacturer (OEM) monitor; (c) generate ...
This shall promote (a) reusability of algorithms across different CCU domains; (b) evaluation on different OEM monitor data; (c) fair comparison through formalised SQIs; (d) meaningful integration with ...
Therefore, adoption of a standardised structured approach for design and reporting of standalone and coupled AD research is recommended. ...
doi:10.1109/rbme.2013.2243724
pmid:23372087
fatcat:qbl5kfzefrf4pbm2av3tzhrjve
Deep Neural Networks and Transfer Learning on a Multivariate Physiological Signal Dataset
2021
Bioengineering
After the DNN was trained to optimally classify the type of signal, the features that were automatically extracted by the DNN were used to classify the type of device used for the acquisition using a Support ...
Signals were collected from 232 subjects using four different acquisition devices. ...
of the Affiliative Behavior and Physiology lab (University of Trento, Italy), for their assistance in this work. ...
doi:10.3390/bioengineering8030035
pmid:33800842
pmcid:PMC8058952
fatcat:tyy7piftq5a3bc7utkm7prss5a
Critical Appraisal of Surface Electromyography (sEMG) as a Taught Subject and Clinical Tool in Medicine and Kinesiology
2020
Frontiers in Neurology
The characteristics and state of knowledge of bioelectric signals such as ECG, EEG, and EMG are initially discussed. ...
, psychiatry, physiatry, physical medicine and rehabilitation, biomechanics and motor control, and gnathology, is evaluated. ...
In combination with kinematic and kinetic measurement data, multichannel sEMG forms a standard component of instrumental setups in motion analysis laboratories aimed at measuring human posture and movement ...
doi:10.3389/fneur.2020.560363
pmid:33192993
pmcid:PMC7649227
fatcat:acdbrnjksbbvrpp3h2kseii3j4
E-health-IoT Universe: A Review
2017
International Journal on Advanced Science, Engineering and Information Technology
The Internet of Things (IoT) devices are able to collect and share data directly with other devices through the cloud environment, providing a huge amount of information to be gathered, stored and analyzed ...
and most importantly increasing the quality of life of the patients. ...
When utilizing data at a local/institutional level, an important aspect of a research project is on how the developed system is evaluated and validated. ...
doi:10.18517/ijaseit.7.6.4467
fatcat:zcp3hcbrkvbcdgziv32njomrci
« Previous
Showing results 1 — 15 out of 204 results