Filters








566 Hits in 4.0 sec

Imaging of coronary artery calcification

William L Simpson, David S Mendelson
<span title="">2002</span> <i title="Wiley (John Wiley &amp; Sons)"> <a target="_blank" rel="noopener" href="https://fatcat.wiki/container/n6gxxodkave23cp4k55llypikm" style="color: black;">The Mount Sinai journal of medicine</a> </i> &nbsp;
The coronary calcium score is based on both the area and density of the calcification.  ...  With the advent of electron-beam computed tomography and subsecond helical computed tomography, a method of screening for and quantitating the amount of coronary calcification has been developed.  ...  At about the same time, the Japanese developed a calcifica- tion scoring system using conventional CT, based on the length of calcifications (28), but it did not gain widespread acceptance.  ... 
<span class="external-identifiers"> <a target="_blank" rel="external noopener" href="https://www.ncbi.nlm.nih.gov/pubmed/12035072">pmid:12035072</a> <a target="_blank" rel="external noopener" href="https://fatcat.wiki/release/jza24yv7pza2lbe54wtj3vrmgq">fatcat:jza24yv7pza2lbe54wtj3vrmgq</a> </span>
<a target="_blank" rel="noopener" href="https://archive.org/details/sim_mount-sinai-journal-of-medicine_2002-05_69_3/page/132" title="read fulltext microfilm" data-goatcounter-click="serp-fulltext" data-goatcounter-title="serp-fulltext"> <button class="ui simple right pointing dropdown compact black labeled icon button serp-button"> <i class="icon ia-icon"></i> Archive [Microfilm] <div class="menu fulltext-thumbnail"> <img src="https://archive.org/serve/sim_mount-sinai-journal-of-medicine_2002-05_69_3/__ia_thumb.jpg" alt="fulltext thumbnail" loading="lazy"> </div> </button> </a>

Combined evaluation of myocardial perfusion and coronary morphology in the identification of subclinical CAD

G. Vincenti, A. Quercioli, H. Zaïdi, R. Nkoulou, S. Dewarrat, O. Rager, G. Ambrosio, Y. Seimbille, F. Mach, O. Ratib, T. H. Schindler
<span title="2010-07-22">2010</span> <i title="Schattauer GmbH"> <a target="_blank" rel="noopener" href="https://fatcat.wiki/container/y77tkicmzzaz3hp4en5akq3hwy" style="color: black;">NuclearMedicine</a> </i> &nbsp;
mean effective radiation dose of 13 N-ammonia PET/CT and ECGpulsing CT angiography (CTA) in the evaluation of myocardial perfusion, myocardial blood flow (MBF) and coronary morphology for the identification  ...  Conclusion: 13 N-ammonia PET/CT and ECG-pulsing CTA affords cardiac hybrid imaging studies in the evaluation of subclinical CAD with a relatively low mean effective radiation exposure of 8.0 ± 1.5mSv.  ...  Conflict of interest The authors declare, that no potential conflict of interest exists and all sources of funding for the work are acknowledged .  ... 
<span class="external-identifiers"> <a target="_blank" rel="external noopener noreferrer" href="https://doi.org/10.3413/nukmed-0312">doi:10.3413/nukmed-0312</a> <a target="_blank" rel="external noopener" href="https://www.ncbi.nlm.nih.gov/pubmed/20664888">pmid:20664888</a> <a target="_blank" rel="external noopener" href="https://fatcat.wiki/release/fy3gdfkve5esjadq5gc524ucbi">fatcat:fy3gdfkve5esjadq5gc524ucbi</a> </span>
<a target="_blank" rel="noopener" href="https://web.archive.org/web/20170810081218/http://pinlab.hcuge.ch/pdf/NuklearMedizin2010.pdf" title="fulltext PDF download" data-goatcounter-click="serp-fulltext" data-goatcounter-title="serp-fulltext"> <button class="ui simple right pointing dropdown compact black labeled icon button serp-button"> <i class="icon ia-icon"></i> Web Archive [PDF] <div class="menu fulltext-thumbnail"> <img src="https://blobs.fatcat.wiki/thumbnail/pdf/a3/27/a3271a3068e97ef0bf349cf852c577f93450fba7.180px.jpg" alt="fulltext thumbnail" loading="lazy"> </div> </button> </a> <a target="_blank" rel="external noopener noreferrer" href="https://doi.org/10.3413/nukmed-0312"> <button class="ui left aligned compact blue labeled icon button serp-button"> <i class="external alternate icon"></i> Publisher / doi.org </button> </a>

Optimization of scanning protocols in low-dose, prospectively ECG-triggered, high-pitch spiral coronary CT angiography

M. Kruk, L. Wardziak, A. Kowalewska, M. Demkow, W. Ruzyllo, J. Pregowski, C. Kepka
<span title="2013-08-02">2013</span> <i title="Oxford University Press (OUP)"> <a target="_blank" rel="noopener" href="https://fatcat.wiki/container/uya4vqptcrdklazphdg2nqow5u" style="color: black;">European Heart Journal</a> </i> &nbsp;
In all patients two high-pitch scans were performed on dual source CT scanner (Definition Flash) and diagnostic value of the images was immediately assessed.  ...  Recently, due to technical development of CT scanners, a new high-pitch (FLASH) scan mode for coronary CTA became available, which allows effective dose below 1 mSv/scan in most studies.  ...  HR variability had a slight impact on image quality for HPS (P<0.05), not for LPS/SEQ (P>0.05).  ... 
<span class="external-identifiers"> <a target="_blank" rel="external noopener noreferrer" href="https://doi.org/10.1093/eurheartj/eht310.p4697">doi:10.1093/eurheartj/eht310.p4697</a> <a target="_blank" rel="external noopener" href="https://fatcat.wiki/release/di2pwqjspvap3m5gtu3xkskijm">fatcat:di2pwqjspvap3m5gtu3xkskijm</a> </span>
<a target="_blank" rel="noopener" href="https://web.archive.org/web/20180728145415/https://watermark.silverchair.com/eht310.P4697.pdf?token=AQECAHi208BE49Ooan9kkhW_Ercy7Dm3ZL_9Cf3qfKAc485ysgAAAcgwggHEBgkqhkiG9w0BBwagggG1MIIBsQIBADCCAaoGCSqGSIb3DQEHATAeBglghkgBZQMEAS4wEQQMaEKFj9b5dHCMSpPiAgEQgIIBe-xU8LfOOloQ9eZq7CJDa19JimQZFiqzIkGNT1Xi_BCAdOEg74xlaD1ipWtPhSBhVRhsHmId6KMAnKbuof7Fk5sNATHonZ-8K-0n_edjfkhB-I3J4s8NYAB_xJRufbyJX6IRsLMNFsA5VLJabdAdnztQy3cf1YJHJqvmgTv0tArBOb-By1NyLxtDy0NDm7V591TXeX1qcFvCevvqpyAR0Bm-p3L2L8tglfYVrc52m_RXAYY85Dw5rfpZWf03oVkDPKuzhKXB6x7C4uWpIoEcKwqt1IhCwv8Ynh8xL_BEFmjbwCVd6vS3wNviES0f-Mcx-hW8MPqfnraZRLiuyfqAG7bTgAf6-bfNk11y0CLiHEOTtn0EmFRDFoLpb805D2DiBnsF-KpVOI-80hvFLvUN1iLOzn1vj_fCe2nHmFp0u4Kv44XnNR4hhcg_JA1TtfvTY9RW2cf4uoegyaXg3Dv45KRx7BfvAsol_Vxd-WkyGRqwP553qRHqJ0mlE90" title="fulltext PDF download" data-goatcounter-click="serp-fulltext" data-goatcounter-title="serp-fulltext"> <button class="ui simple right pointing dropdown compact black labeled icon button serp-button"> <i class="icon ia-icon"></i> Web Archive [PDF] <div class="menu fulltext-thumbnail"> <img src="https://blobs.fatcat.wiki/thumbnail/pdf/b2/17/b217de3d5eeecae8b161d43859264681ffe256d7.180px.jpg" alt="fulltext thumbnail" loading="lazy"> </div> </button> </a> <a target="_blank" rel="external noopener noreferrer" href="https://doi.org/10.1093/eurheartj/eht310.p4697"> <button class="ui left aligned compact blue labeled icon button serp-button"> <i class="external alternate icon"></i> oup.com </button> </a>

Prognosis of patients with non-significant coronary artery stenosis detected by dual-source MDCT coronary angiography

H. Yorgun, U. Canpolat, H. Sunman, L. Sahiner, B. Kaya, L. Tokgozoglu, K. Aytemir, G. Kabakci, T. Hazirolan, A. Oto
<span title="2013-08-02">2013</span> <i title="Oxford University Press (OUP)"> <a target="_blank" rel="noopener" href="https://fatcat.wiki/container/uya4vqptcrdklazphdg2nqow5u" style="color: black;">European Heart Journal</a> </i> &nbsp;
In all patients two high-pitch scans were performed on dual source CT scanner (Definition Flash) and diagnostic value of the images was immediately assessed.  ...  Recently, due to technical development of CT scanners, a new high-pitch (FLASH) scan mode for coronary CTA became available, which allows effective dose below 1 mSv/scan in most studies.  ...  HR variability had a slight impact on image quality for HPS (P<0.05), not for LPS/SEQ (P>0.05).  ... 
<span class="external-identifiers"> <a target="_blank" rel="external noopener noreferrer" href="https://doi.org/10.1093/eurheartj/eht310.p4698">doi:10.1093/eurheartj/eht310.p4698</a> <a target="_blank" rel="external noopener" href="https://fatcat.wiki/release/oziqp2sxefas7g72qhvk256hd4">fatcat:oziqp2sxefas7g72qhvk256hd4</a> </span>
<a target="_blank" rel="noopener" href="https://web.archive.org/web/20180729035348/https://watermark.silverchair.com/eht310.P4698.pdf?token=AQECAHi208BE49Ooan9kkhW_Ercy7Dm3ZL_9Cf3qfKAc485ysgAAAckwggHFBgkqhkiG9w0BBwagggG2MIIBsgIBADCCAasGCSqGSIb3DQEHATAeBglghkgBZQMEAS4wEQQMNfn3BQOOK309pc5FAgEQgIIBfNOlPObtJ1MlTzRsoKuvwlUGYum-Svr1hyWrN5Dis578m194BBZt64FFzE2_Vkq6SRKgdDWaMRIxvaKOoClRGgdDrCaLmysOCT-dno6tTicd40yA7ukA0rtnXFW1u-bPBR83szzqczlIVb47lVvnTczsfSEskhBszK9IJiwiSrv-qGd9u65JBLuQwqEIx1vqeAm7dq6V7I7BJBQIqnyLhxkqbRAVlL0ioX8U2XcPh8lsanqUn26M0vUQYdLOKB0WDCOl133tqX-60IaE9f_t6wo-cqYAQygWmu6ZDidhbhTbHwQuNPDoWF7FkKsTxgjuwqzaA-ab4x5UpROu8iMoRtEtNBtnb5T8sQRw1VjobCL8FcwEPKmNVIb_zvKgL66bjJLaFoZtlDNbTRD8Ut1wOtJowU0EL-ef_xAO4krvFTTsGwwzaD4m2Zv1n6X6dshCIAbXYuuNNmrhK-Jn1NtlvJ5EcjZq7Q-OFXdNzMFla4Du87JAgRKiAU3ga6o2" title="fulltext PDF download" data-goatcounter-click="serp-fulltext" data-goatcounter-title="serp-fulltext"> <button class="ui simple right pointing dropdown compact black labeled icon button serp-button"> <i class="icon ia-icon"></i> Web Archive [PDF] <div class="menu fulltext-thumbnail"> <img src="https://blobs.fatcat.wiki/thumbnail/pdf/2c/31/2c31beab0bedab9c856b71d2ad1039948c53228e.180px.jpg" alt="fulltext thumbnail" loading="lazy"> </div> </button> </a> <a target="_blank" rel="external noopener noreferrer" href="https://doi.org/10.1093/eurheartj/eht310.p4698"> <button class="ui left aligned compact blue labeled icon button serp-button"> <i class="external alternate icon"></i> oup.com </button> </a>

Teleradiology network system using the web medical image conference system with a new information security solution

Hitoshi Satoh, Noboru Niki, Kenji Eguchi, Hironobu Ohmatsu, Masahiro Kusumoto, Masahiro Kaneko, Ryutaru Kakinuma, Noriyuki Moriyama, William W. Boonn, Brent J. Liu
<span title="2012-02-16">2012</span> <i title="SPIE"> Medical Imaging 2012: Advanced PACS-based Imaging Informatics and Therapeutic Applications </i> &nbsp;
We have developed the teleradiology network system with a new information security solution that provided with web medical image conference system.  ...  In the teleradiology network system, the security of information network is very important subjects.  ...  We would like to thank View Send ICT Corporation who is our research cooperator for providing the Web medical image conference system.  ... 
<span class="external-identifiers"> <a target="_blank" rel="external noopener noreferrer" href="https://doi.org/10.1117/12.911431">doi:10.1117/12.911431</a> <a target="_blank" rel="external noopener" href="https://fatcat.wiki/release/te4i2tdg5zg5vlcjtfngg2mcim">fatcat:te4i2tdg5zg5vlcjtfngg2mcim</a> </span>
<a target="_blank" rel="noopener" href="https://web.archive.org/web/20180722155437/https://www.spiedigitallibrary.org/conference-proceedings-of-spie/8319/83190Y/Teleradiology-network-system-using-the-web-medical-image-conference-system/10.1117/12.911431.pdf" title="fulltext PDF download" data-goatcounter-click="serp-fulltext" data-goatcounter-title="serp-fulltext"> <button class="ui simple right pointing dropdown compact black labeled icon button serp-button"> <i class="icon ia-icon"></i> Web Archive [PDF] <div class="menu fulltext-thumbnail"> <img src="https://blobs.fatcat.wiki/thumbnail/pdf/01/0a/010a4ea9b15a5cdfac35fa5849c9f09e9e48d454.180px.jpg" alt="fulltext thumbnail" loading="lazy"> </div> </button> </a> <a target="_blank" rel="external noopener noreferrer" href="https://doi.org/10.1117/12.911431"> <button class="ui left aligned compact blue labeled icon button serp-button"> <i class="external alternate icon"></i> Publisher / doi.org </button> </a>

PET/CT: challenge for nuclear cardiology

Markus Schwaiger, Sibylle Ziegler, Stephan G Nekolla
<span title="">2005</span> <i title="Society of Nuclear Medicine"> <a target="_blank" rel="noopener" href="https://fatcat.wiki/container/es34xtfdxrgybg2kmdq2n5xqry" style="color: black;">Journal of Nuclear Medicine</a> </i> &nbsp;
This review focuses on the clinical potential of PET/CT for the characterization of coronary artery disease.  ...  We describe the technical challenges of combining instrumentation with very different imaging performances and speculate on future clinical applications in the field of cardiology.  ...  The authors thank David McElroy for his editorial assistance.  ... 
<span class="external-identifiers"> <a target="_blank" rel="external noopener" href="https://www.ncbi.nlm.nih.gov/pubmed/16204717">pmid:16204717</a> <a target="_blank" rel="external noopener" href="https://fatcat.wiki/release/sbwkg477lbdorowrthnxapw76a">fatcat:sbwkg477lbdorowrthnxapw76a</a> </span>
<a target="_blank" rel="noopener" href="https://web.archive.org/web/20200321213154/http://jnm.snmjournals.org/content/46/10/1664.full.pdf" title="fulltext PDF download" data-goatcounter-click="serp-fulltext" data-goatcounter-title="serp-fulltext"> <button class="ui simple right pointing dropdown compact black labeled icon button serp-button"> <i class="icon ia-icon"></i> Web Archive [PDF] <div class="menu fulltext-thumbnail"> <img src="https://blobs.fatcat.wiki/thumbnail/pdf/ef/68/ef6853af1ea4e41cb54685e19d7216b80fb1f95c.180px.jpg" alt="fulltext thumbnail" loading="lazy"> </div> </button> </a>

Adding calcium scoring to myocardial perfusion imaging: Does it alter physicians' therapeutic decision making?

Ron Blankstein, Sharmila Dorbala
<span title="2009-12-29">2009</span> <i title="Springer Nature"> <a target="_blank" rel="noopener" href="https://fatcat.wiki/container/24ofo5bdvzd2lizjdo4i75ge5a" style="color: black;">Journal of Nuclear Cardiology</a> </i> &nbsp;
On the other hand, for scans utilizing the 16-slice system, a helical acquisition with tube current modulation was used (120 kV, 200 mAs, 1.5 mm collimation, 0.28 pitch) and the estimated radiation dose  ...  based on the Diamond and Forrester criteria).  ... 
<span class="external-identifiers"> <a target="_blank" rel="external noopener noreferrer" href="https://doi.org/10.1007/s12350-009-9185-7">doi:10.1007/s12350-009-9185-7</a> <a target="_blank" rel="external noopener" href="https://www.ncbi.nlm.nih.gov/pubmed/20039150">pmid:20039150</a> <a target="_blank" rel="external noopener" href="https://fatcat.wiki/release/vk7nwml7tngxzb7pu6sgtpwjje">fatcat:vk7nwml7tngxzb7pu6sgtpwjje</a> </span>
<a target="_blank" rel="noopener" href="https://web.archive.org/web/20180725100233/https://link.springer.com/content/pdf/10.1007%2Fs12350-009-9185-7.pdf" title="fulltext PDF download" data-goatcounter-click="serp-fulltext" data-goatcounter-title="serp-fulltext"> <button class="ui simple right pointing dropdown compact black labeled icon button serp-button"> <i class="icon ia-icon"></i> Web Archive [PDF] <div class="menu fulltext-thumbnail"> <img src="https://blobs.fatcat.wiki/thumbnail/pdf/f0/39/f0398ef68f8492f8b0dd3a47b8f3a5c35cd2ae86.180px.jpg" alt="fulltext thumbnail" loading="lazy"> </div> </button> </a> <a target="_blank" rel="external noopener noreferrer" href="https://doi.org/10.1007/s12350-009-9185-7"> <button class="ui left aligned compact blue labeled icon button serp-button"> <i class="external alternate icon"></i> springer.com </button> </a>

CT Coronary Angiography Is Feasible for the Assessment of Coronary Artery Disease in Chronic Dialysis Patients, Despite High Average Calcium Scores

Mihály K. de Bie, Maurits S. Buiten, André Gaasbeek, Mark J. Boogers, Cornelis J. Roos, Joanne D. Schuijf, M. Jacqueline Krol, Ton J. Rabelink, Jeroen J. Bax, Martin J. Schalij, J. Wouter Jukema, Xiaoming Yang
<span title="2013-07-10">2013</span> <i title="Public Library of Science (PLoS)"> <a target="_blank" rel="noopener" href="https://fatcat.wiki/container/s3gm7274mfe6fcs7e3jterqlri" style="color: black;">PLoS ONE</a> </i> &nbsp;
Moreover the presence of significant CAD on CT was associated with events during follow-up.  ...  CT-angiography may therefore be more appropriate. However, extensive coronary calcification, often present in this patient group, might hamper adequate lumen evaluation.  ...  Based on a segmental reconstruction algorithm, data of one, two or three consecutive heartbeats were used to generate a single image.  ... 
<span class="external-identifiers"> <a target="_blank" rel="external noopener noreferrer" href="https://doi.org/10.1371/journal.pone.0067936">doi:10.1371/journal.pone.0067936</a> <a target="_blank" rel="external noopener" href="https://www.ncbi.nlm.nih.gov/pubmed/23874471">pmid:23874471</a> <a target="_blank" rel="external noopener" href="https://pubmed.ncbi.nlm.nih.gov/PMC3707871/">pmcid:PMC3707871</a> <a target="_blank" rel="external noopener" href="https://fatcat.wiki/release/ceytpg4tozey5n6nqtucizorh4">fatcat:ceytpg4tozey5n6nqtucizorh4</a> </span>
<a target="_blank" rel="noopener" href="https://web.archive.org/web/20171007154553/http://journals.plos.org/plosone/article/file?id=10.1371/journal.pone.0067936&amp;type=printable" title="fulltext PDF download" data-goatcounter-click="serp-fulltext" data-goatcounter-title="serp-fulltext"> <button class="ui simple right pointing dropdown compact black labeled icon button serp-button"> <i class="icon ia-icon"></i> Web Archive [PDF] <div class="menu fulltext-thumbnail"> <img src="https://blobs.fatcat.wiki/thumbnail/pdf/48/d0/48d0516bdcf549f425899722b6ed641ef4e44e9e.180px.jpg" alt="fulltext thumbnail" loading="lazy"> </div> </button> </a> <a target="_blank" rel="external noopener noreferrer" href="https://doi.org/10.1371/journal.pone.0067936"> <button class="ui left aligned compact blue labeled icon button serp-button"> <i class="unlock alternate icon" style="background-color: #fb971f;"></i> plos.org </button> </a> <a target="_blank" rel="external noopener" href="https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3707871" title="pubmed link"> <button class="ui compact blue labeled icon button serp-button"> <i class="file alternate outline icon"></i> pubmed.gov </button> </a>

Incremental predictive value for obstructive coronary artery disease by combination of Duke Clinical Score and Agatston score

Kazuhisa Takamura, Takeshi Kondo, Shinichiro Fujimoto, Makoto Hiki, Rie Matsumori, Yuko Kawaguchi, Makoto Amanuma, Shinichi Takase, Hiroyuki Daida
<span title="2015-09-28">2015</span> <i title="Oxford University Press (OUP)"> <a target="_blank" rel="noopener" href="https://fatcat.wiki/container/bpzphzxlnjafnlh625unjjm23q" style="color: black;">European Heart Journal-Cardiovascular Imaging</a> </i> &nbsp;
The Agatston score representing the grade of coronary artery calcification can be simply calculated from low-radiation exposure ECG-gated plain CT.  ...  Obstructive CAD was defined as .50% diameter stenosis on CCTA; we investigated the diagnostic performance based on the area under the curve (AUC) of a receiver operating characteristic (ROC) curve, Net  ...  Acknowledgements We are indebted to Medical English Service for assistance in translating the manuscript and to Dr Chiaki Nishimura for advice in the statistical analysis of the data.  ... 
<span class="external-identifiers"> <a target="_blank" rel="external noopener noreferrer" href="https://doi.org/10.1093/ehjci/jev233">doi:10.1093/ehjci/jev233</a> <a target="_blank" rel="external noopener" href="https://www.ncbi.nlm.nih.gov/pubmed/26420291">pmid:26420291</a> <a target="_blank" rel="external noopener" href="https://fatcat.wiki/release/ewemwoqejbbebbvllu4fn2isaq">fatcat:ewemwoqejbbebbvllu4fn2isaq</a> </span>
<a target="_blank" rel="noopener" href="https://web.archive.org/web/20190228182639/http://pdfs.semanticscholar.org/969f/c44db9401ff30fc92e7e042262022a4b606e.pdf" title="fulltext PDF download" data-goatcounter-click="serp-fulltext" data-goatcounter-title="serp-fulltext"> <button class="ui simple right pointing dropdown compact black labeled icon button serp-button"> <i class="icon ia-icon"></i> Web Archive [PDF] <div class="menu fulltext-thumbnail"> <img src="https://blobs.fatcat.wiki/thumbnail/pdf/96/9f/969fc44db9401ff30fc92e7e042262022a4b606e.180px.jpg" alt="fulltext thumbnail" loading="lazy"> </div> </button> </a> <a target="_blank" rel="external noopener noreferrer" href="https://doi.org/10.1093/ehjci/jev233"> <button class="ui left aligned compact blue labeled icon button serp-button"> <i class="external alternate icon"></i> oup.com </button> </a>

Reducing Radiation Dose in Rest-Stress Cardiac PET/CT by Single Poststress Cine CT for Attenuation Correction: Quantitative Validation

K. L. Gould, T. Pan, C. Loghin, N. P. Johnson, S. Sdringola
<span title="2008-04-15">2008</span> <i title="Society of Nuclear Medicine"> <a target="_blank" rel="noopener" href="https://fatcat.wiki/container/es34xtfdxrgybg2kmdq2n5xqry" style="color: black;">Journal of Nuclear Medicine</a> </i> &nbsp;
To reduce radiation dose, we tested quantitative accuracy of using a single poststress cine CT attenuation scan for reconstructing rest perfusion images to eliminate resting CT attenuation scans.  ...  Separate rest and stress CT scans incur greater radiation dose to patients than does standard helical PET/CT or "pure" PET using rotating rod attenuation sources.  ...  However, a lower amperage degrades the images sufficiently to preclude assessing coronary calcification or using the initial helical scan for attenuation correction in the rare instance of the cine CT  ... 
<span class="external-identifiers"> <a target="_blank" rel="external noopener noreferrer" href="https://doi.org/10.2967/jnumed.107.049163">doi:10.2967/jnumed.107.049163</a> <a target="_blank" rel="external noopener" href="https://www.ncbi.nlm.nih.gov/pubmed/18413384">pmid:18413384</a> <a target="_blank" rel="external noopener" href="https://fatcat.wiki/release/eempimnevzcarb2dgfzxhalhk4">fatcat:eempimnevzcarb2dgfzxhalhk4</a> </span>
<a target="_blank" rel="noopener" href="https://web.archive.org/web/20190307132316/http://pdfs.semanticscholar.org/d726/09c2a4f307ab102b7b89348c4617616ddb44.pdf" title="fulltext PDF download" data-goatcounter-click="serp-fulltext" data-goatcounter-title="serp-fulltext"> <button class="ui simple right pointing dropdown compact black labeled icon button serp-button"> <i class="icon ia-icon"></i> Web Archive [PDF] <div class="menu fulltext-thumbnail"> <img src="https://blobs.fatcat.wiki/thumbnail/pdf/d7/26/d72609c2a4f307ab102b7b89348c4617616ddb44.180px.jpg" alt="fulltext thumbnail" loading="lazy"> </div> </button> </a> <a target="_blank" rel="external noopener noreferrer" href="https://doi.org/10.2967/jnumed.107.049163"> <button class="ui left aligned compact blue labeled icon button serp-button"> <i class="external alternate icon"></i> Publisher / doi.org </button> </a>

Coronary CT angiography: Diagnostic value and clinical challenges

Akmal Sabarudin, Zhonghua Sun
<span title="">2013</span> <i title="Baishideng Publishing Group Inc."> <a target="_blank" rel="noopener" href="https://fatcat.wiki/container/x56rhp2g6vahndguj4dsqi5eay" style="color: black;">World Journal of Cardiology</a> </i> &nbsp;
The aim o� this review is to present an overview o� the technical developments o� multislice CT and diagnostic value o� coronary CT angiography in coronary artery disease based on di��erent generations  ...  calcification.  ...  Studies based on single centre experiences have demonstrated that CCTA provides prognostic information for predictive adverse cardiac events in patients with known or suspected CAD [62] [63] [64] [65]  ... 
<span class="external-identifiers"> <a target="_blank" rel="external noopener noreferrer" href="https://doi.org/10.4330/wjc.v5.i12.473">doi:10.4330/wjc.v5.i12.473</a> <a target="_blank" rel="external noopener" href="https://www.ncbi.nlm.nih.gov/pubmed/24392192">pmid:24392192</a> <a target="_blank" rel="external noopener" href="https://pubmed.ncbi.nlm.nih.gov/PMC3879693/">pmcid:PMC3879693</a> <a target="_blank" rel="external noopener" href="https://fatcat.wiki/release/eckgog2tbjfwdieffxfj7cc2vq">fatcat:eckgog2tbjfwdieffxfj7cc2vq</a> </span>
<a target="_blank" rel="noopener" href="https://web.archive.org/web/20190303110859/http://pdfs.semanticscholar.org/b472/270b56f645fdd0546a5fc35a0e9e4e3db6b0.pdf" title="fulltext PDF download" data-goatcounter-click="serp-fulltext" data-goatcounter-title="serp-fulltext"> <button class="ui simple right pointing dropdown compact black labeled icon button serp-button"> <i class="icon ia-icon"></i> Web Archive [PDF] <div class="menu fulltext-thumbnail"> <img src="https://blobs.fatcat.wiki/thumbnail/pdf/b4/72/b472270b56f645fdd0546a5fc35a0e9e4e3db6b0.180px.jpg" alt="fulltext thumbnail" loading="lazy"> </div> </button> </a> <a target="_blank" rel="external noopener noreferrer" href="https://doi.org/10.4330/wjc.v5.i12.473"> <button class="ui left aligned compact blue labeled icon button serp-button"> <i class="unlock alternate icon" style="background-color: #fb971f;"></i> Publisher / doi.org </button> </a> <a target="_blank" rel="external noopener" href="https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3879693" title="pubmed link"> <button class="ui compact blue labeled icon button serp-button"> <i class="file alternate outline icon"></i> pubmed.gov </button> </a>

Noninvasive imaging modalities to visualize atherosclerotic plaques

Daisuke Shishikura
<span title="">2016</span> <i title="AME Publishing Company"> <a target="_blank" rel="noopener" href="https://fatcat.wiki/container/nrivcrm4q5eqdar5acgednv6by" style="color: black;">Cardiovascular Diagnosis and Therapy</a> </i> &nbsp;
The diagnostic performance of FFR CT is impaired by CT imaging artifacts including misalignment, motion, beam hardening from coronary calcification, and increased image noise.  ...  Recently, technological innovation allows to calculate coronary flow and pressure based on anatomic MDCT image data without hyperemia, thereby measuring FFR noninvasively (35, 36) .  ... 
<span class="external-identifiers"> <a target="_blank" rel="external noopener noreferrer" href="https://doi.org/10.21037/cdt.2015.11.07">doi:10.21037/cdt.2015.11.07</a> <a target="_blank" rel="external noopener" href="https://www.ncbi.nlm.nih.gov/pubmed/27500092">pmid:27500092</a> <a target="_blank" rel="external noopener" href="https://pubmed.ncbi.nlm.nih.gov/PMC4960065/">pmcid:PMC4960065</a> <a target="_blank" rel="external noopener" href="https://fatcat.wiki/release/bkftu22dgzgxnd4lr2thnaa6de">fatcat:bkftu22dgzgxnd4lr2thnaa6de</a> </span>
<a target="_blank" rel="noopener" href="https://web.archive.org/web/20190225171333/http://pdfs.semanticscholar.org/659c/841c66d75ae785881db8ef6b00dd5e37f9f9.pdf" title="fulltext PDF download" data-goatcounter-click="serp-fulltext" data-goatcounter-title="serp-fulltext"> <button class="ui simple right pointing dropdown compact black labeled icon button serp-button"> <i class="icon ia-icon"></i> Web Archive [PDF] <div class="menu fulltext-thumbnail"> <img src="https://blobs.fatcat.wiki/thumbnail/pdf/65/9c/659c841c66d75ae785881db8ef6b00dd5e37f9f9.180px.jpg" alt="fulltext thumbnail" loading="lazy"> </div> </button> </a> <a target="_blank" rel="external noopener noreferrer" href="https://doi.org/10.21037/cdt.2015.11.07"> <button class="ui left aligned compact blue labeled icon button serp-button"> <i class="external alternate icon"></i> Publisher / doi.org </button> </a> <a target="_blank" rel="external noopener" href="https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4960065" title="pubmed link"> <button class="ui compact blue labeled icon button serp-button"> <i class="file alternate outline icon"></i> pubmed.gov </button> </a>

Multislice helical CT of the heart with retrospective ECG gating: reduction of radiation exposure by ECG-controlled tube current modulation

Tobias F. Jakobs, Christoph R. Becker, Bernd Ohnesorge, Thomas Flohr, Christoph Suess, Uwe J. Schoepf, Maximilian F. Reiser
<span title="2002-02-21">2002</span> <i title="Springer Nature"> <a target="_blank" rel="noopener" href="https://fatcat.wiki/container/y352pep6tjcphcqt3p6tv3d7se" style="color: black;">European Radiology</a> </i> &nbsp;
One hundred patients underwent MSCT scanning (Somatom VolumeZoom, Siemens, Forchheim, Germany) for detection of coronary artery calcifications.  ...  Our objective was to evaluate image quality and radiation exposure of retrospectively ECG-gated multislice helical CT (MSCT) investigations of the heart with ECG-controlled tube current modulation.  ...  Both, electron beam CT and conventional single detector row CT, have been used for detection and quantification of coronary calcifications as a sign of coronary atherosclerosis [8] .  ... 
<span class="external-identifiers"> <a target="_blank" rel="external noopener noreferrer" href="https://doi.org/10.1007/s00330-001-1278-x">doi:10.1007/s00330-001-1278-x</a> <a target="_blank" rel="external noopener" href="https://www.ncbi.nlm.nih.gov/pubmed/11976849">pmid:11976849</a> <a target="_blank" rel="external noopener" href="https://fatcat.wiki/release/xdxmoafgfzcnhn3fllucvu45sq">fatcat:xdxmoafgfzcnhn3fllucvu45sq</a> </span>
<a target="_blank" rel="noopener" href="https://web.archive.org/web/20171014232601/http://publisher-connector.core.ac.uk/resourcesync/data/Springer-OA/pdf/7c5/aHR0cDovL2xpbmsuc3ByaW5nZXIuY29tLzEwLjEwMDcvczAwMzMwLTAwMS0xMjc4LXgucGRm.pdf" title="fulltext PDF download" data-goatcounter-click="serp-fulltext" data-goatcounter-title="serp-fulltext"> <button class="ui simple right pointing dropdown compact black labeled icon button serp-button"> <i class="icon ia-icon"></i> Web Archive [PDF] <div class="menu fulltext-thumbnail"> <img src="https://blobs.fatcat.wiki/thumbnail/pdf/b2/e3/b2e3ca30a46d04c8e0c14400901efc8705afcd06.180px.jpg" alt="fulltext thumbnail" loading="lazy"> </div> </button> </a> <a target="_blank" rel="external noopener noreferrer" href="https://doi.org/10.1007/s00330-001-1278-x"> <button class="ui left aligned compact blue labeled icon button serp-button"> <i class="external alternate icon"></i> springer.com </button> </a>

Computed tomography coronary angiography – past, present and future

PI Ngam, CC Ong, P Chai, SS Wong, CR Liang, LLS Teo
<span title="">2020</span> <i title="Singapore Medical Journal"> <a target="_blank" rel="noopener" href="https://fatcat.wiki/container/oozaw2pnfvawnhapy7svkgjwye" style="color: black;">Singapore medical journal</a> </i> &nbsp;
We also highlight the future directions of CTCA as a one-stop non-invasive imaging modality for anatomic and functional assessment of CAD.  ...  CTCA has high negative predictive value and can confidently exclude significant coronary artery disease (CAD) in low to intermediate risk patients.  ...  The era of computed tomography (CT) imaging of the coronary arteries began in the late 1990s, with the widespread introduction of single-slice helical CT systems.  ... 
<span class="external-identifiers"> <a target="_blank" rel="external noopener noreferrer" href="https://doi.org/10.11622/smedj.2020028">doi:10.11622/smedj.2020028</a> <a target="_blank" rel="external noopener" href="https://www.ncbi.nlm.nih.gov/pubmed/32488269">pmid:32488269</a> <a target="_blank" rel="external noopener" href="https://fatcat.wiki/release/wx7txovi2navpct6cgrh64aoki">fatcat:wx7txovi2navpct6cgrh64aoki</a> </span>
<a target="_blank" rel="noopener" href="https://web.archive.org/web/20200507152812/http://www.smj.org.sg/sites/default/files/SMJ-61-109.pdf" title="fulltext PDF download" data-goatcounter-click="serp-fulltext" data-goatcounter-title="serp-fulltext"> <button class="ui simple right pointing dropdown compact black labeled icon button serp-button"> <i class="icon ia-icon"></i> Web Archive [PDF] <div class="menu fulltext-thumbnail"> <img src="https://blobs.fatcat.wiki/thumbnail/pdf/6b/f4/6bf492d3e37fcc08812fae83008fe5ddc04c9ba1.180px.jpg" alt="fulltext thumbnail" loading="lazy"> </div> </button> </a> <a target="_blank" rel="external noopener noreferrer" href="https://doi.org/10.11622/smedj.2020028"> <button class="ui left aligned compact blue labeled icon button serp-button"> <i class="external alternate icon"></i> Publisher / doi.org </button> </a>

Cardiac Computed Tomography: Technology in Rapid Evolution

Su Min Chang
<span title="2009-01-01">2009</span> <i title="Methodist DeBakey Cardiovascular Journal"> <a target="_blank" rel="noopener" href="https://fatcat.wiki/container/hek7fixljjbnpih6tv6wohapn4" style="color: black;">Methodist DeBakey Cardiovascular Journal</a> </i> &nbsp;
to detect coronary artery disease (CAD).  ...  images of the coronary tree.  ...  In 1989, with the advent of spiral or helical 22 CT systems with subsecond rotation, computed tomography became a widely used vascular imaging modality.  ... 
<span class="external-identifiers"> <a target="_blank" rel="external noopener noreferrer" href="https://doi.org/10.14797/mdcvj.150">doi:10.14797/mdcvj.150</a> <a target="_blank" rel="external noopener" href="https://fatcat.wiki/release/mp2r46bpebf2jjd5377ty5jzae">fatcat:mp2r46bpebf2jjd5377ty5jzae</a> </span>
<a target="_blank" rel="noopener" href="https://web.archive.org/web/20210831134520/https://journal.houstonmethodist.org//articles/10.14797/mdcvj.150/galley/173/download/" title="fulltext PDF download" data-goatcounter-click="serp-fulltext" data-goatcounter-title="serp-fulltext"> <button class="ui simple right pointing dropdown compact black labeled icon button serp-button"> <i class="icon ia-icon"></i> Web Archive [PDF] <div class="menu fulltext-thumbnail"> <img src="https://blobs.fatcat.wiki/thumbnail/pdf/7b/5c/7b5cbf2aa136cb368d93a6acb4f6b2ab5228cc26.180px.jpg" alt="fulltext thumbnail" loading="lazy"> </div> </button> </a> <a target="_blank" rel="external noopener noreferrer" href="https://doi.org/10.14797/mdcvj.150"> <button class="ui left aligned compact blue labeled icon button serp-button"> <i class="unlock alternate icon" style="background-color: #fb971f;"></i> Publisher / doi.org </button> </a>
&laquo; Previous Showing results 1 &mdash; 15 out of 566 results