Filters








1,303 Hits in 5.2 sec

Comparison of Full-Field Digital Mammography and Screen-Film Mammography for Detection and Characterization of Simulated Small Masses

Wei T. Yang, Chao-Jen Lai, Gary J. Whitman, William A. Murphy, Mark J. Dryden, Anne C. Kushwaha, Aysegul A. Sahin, Dennis Johnston, Peter J. Dempsey, Chris C. Shaw
2006 American Journal of Roentgenology  
Full-field digital mammography was superior to screen-film mammography for characterizing round and irregular masses and low-and high-density masses.  ...  OBJECTIVE- The two objectives of this study were to create an ex vivo phantom model that closely mimics human breast cancer for detection tasks and to compare the performance of full-field digital mammography  ...  Full-field digital mammography performed significantly better than screen-film mammography for the detection of low-density masses (p = 0.085) and high-density masses (p < 0.001).  ... 
doi:10.2214/ajr.05.0126 pmid:17114508 pmcid:PMC1892902 fatcat:xgvfw6tgtbfahnszo5xjnjaspm

An Automated Approach for Estimation of Breast Density

J. J. Heine, M. J. Carston, C. G. Scott, K. R. Brandt, F.-F. Wu, V. S. Pankratz, T. A. Sellers, C. M. Vachon
2008 Cancer Epidemiology, Biomarkers and Prevention  
The automated breast density method is a viable option for quantitatively assessing breast density from digitized film mammograms.  ...  The three estimation methods were evaluated in a matched breast cancer case-control (n = 372 and n = 713, respectively) study at the Mayo Clinic using digitized film mammograms.  ...  We thank the women within our mammography practice who provided research authorization for medical record studies.  ... 
doi:10.1158/1055-9965.epi-08-0170 pmid:18990749 pmcid:PMC2705972 fatcat:3uazotpepradneebbc62odty4u

The Positive Predictive Value for Diagnosis of Breast Cancer

Bo Kyoung Seo, Etta D. Pisano, Cherie M. Kuzmiak, Marcia Koomen, Dag Pavic, Robert McLelland, Yeonhee Lee, Elodia B. Cole, Dianne Mattingly, Juneyoung Lee
2006 Academic Radiology  
We included the biopsy-performed lesions, so PPV3 was used for comparison of PPVs between film-screen mammography and full-field digital mammography.  ...  We assessed whether the use of full-field digital mammography would improve the positive predictive value (PPV) for the diagnosis of breast cancer in a diagnostic population compared with film-screen mammography  ...  Full-Field Digital Mammography and Film-screen MammographyThe difference was obtained by subtracting the value for film-screen mammography from the value for full-field digital mammography. ‡ P value  ... 
doi:10.1016/j.acra.2006.07.007 pmid:16979072 fatcat:ttwawfzkezbw5d4yxae5u6pncy

Front Matter: Volume 10718

Elizabeth A. Krupinski
2018 14th International Workshop on Breast Imaging (IWBI 2018)  
Publication of record for individual papers is online in the SPIE Digital Library. SPIEDigitalLibrary.org Paper Numbering: Proceedings of SPIE follow an e-First publication model.  ...  SPIE uses a seven-digit CID article numbering system structured as follows:  The first five digits correspond to the SPIE volume number.  The last two digits indicate publication order within the volume  ...  Introduction SESSION 1 SCREENING & CLINICAL INTERPRETATION 02 Breast compression parameters among women imaged with full field digital mammography and breast tomosynthesis in BreastScreen Norway 10718  ... 
doi:10.1117/12.2502754 dblp:conf/iwbi/X18 fatcat:pwftmdgjcza3lnhzk4yua6npiy

Front Matter: Volume 11513

Chantal Van Ongeval, Nicholas Marshall, Hilde Bosmans
2020 15th International Workshop on Breast Imaging (IWBI2020)  
of digital breast tomosynthesis, synthetic 2D, and conventional full-field digital mammography images for different mammography systems: a multicenter study [11513-77] 11513 1I The relationship between  ...  images [11513-24] 11513 1D Automatic density prediction in low dose mammography [11513-107] 11513 1E Convolutional-neural-network based breast thickness correction in digital breast tomosynthesis  ... 
doi:10.1117/12.2573086 fatcat:jqqvmj7v2jfojckazvemwefh24

Second-Generation 3D Automated Breast Ultrasonography (Prone ABUS) for Dense Breast Cancer Screening Integrated to Mammography: Effectiveness, Performance and Detection Rates

Gianluca Gatta, Salvatore Cappabianca, Daniele La La Forgia, Raffaella Massafra, Annarita Fanizzi, Vincenzo Cuccurullo, Luca Brunese, Alberto Tagliafico, Roberto Grassi
2021 Journal of Personalized Medicine  
Integrating full-field digital mammography (FFDM) with 3D prone ABUS in women with high breast density increases and improves breast cancer detection rates in a significant manner, including small and  ...  In our study, we added a three-dimensional automated breast ultrasound (3D ABUS) to mammography to evaluate the performance and cancer detection rate of mammography alone or with the addition of 3D prone  ...  Acknowledgments: This work was supported by funding from the Italian Ministry of Health "Ri-  ... 
doi:10.3390/jpm11090875 pmid:34575652 pmcid:PMC8468126 fatcat:nm24v7ispba35mmfeuy7uvfzoi

False Positive Value of Computer-Aided Detection in Full Field Digital Mammography in Detection of Breast Malignancy

Awad FM
2015 Journal of Medical Diagnostic Methods  
Full-field digital mammography (FFDM), three-dimensional breast tomosynthesis and computer-aided detection (CAD) were done for all patients.  ...  Objective: The aim of this study is to estimate the false-positive rate of computer-aided detection (CAD) with fullfield digital mammography (FFDM) in the detection of breast cancer.  ...  marks with more confidence, with no need for further investigation. However, if CAD marks were hard to dismiss, further investigation by ultrasound +/-MR mammography was advisable.  ... 
doi:10.4172/2168-9784.1000192 fatcat:qtioqabpnzgvnnhx5vtjsz24ay

Assessment of Average Glandular Dose Received in Full-field Digital Mammography and Digital Breast Tomosynthesis

Napat Ritlumlert, Sutthirak Tangruangkiat, Supannika Kawvised, Phornpailin Pairodsantikul, Phornpailin Pairodsantikul, Sirachat Vidhyarkorn
2020 Journal of Health Science and Medical Research  
Objective: To assess the average glandular doses (AGD) from full-field digital mammography (FFDM) and digital breast tomosynthesis (DBT).  ...  Results: The radiation doses to breasts in terms of ESAK and AGD from FFDM were 4.97±2.29 and 1.36±0.48 milligray (mGy) respectively.  ...  .), Medical Physicist, Lopburi Cancer Hospital for her guidance and language proofreading.  ... 
doi:10.31584/jhsmr.2020730 fatcat:eyc6oy5f6ngt5fclmlj6kb2t2q

The Impact of Acquisition Dose on Quantitative Breast Density Estimation with Digital Mammography: Results from ACRIN PA 4006

Lin Chen, Shonket Ray, Brad M. Keller, Said Pertuz, Elizabeth S. McDonald, Emily F. Conant, Despina Kontos
2016 Radiology  
All patients underwent breast screening with a combination of dose protocols, including standard full-field digital mammography, low-dose digital mammography, and digital breast tomosynthesis.  ...  Purpose: To investigate the impact of radiation dose on breast density estimation in digital mammography.  ...  All patients underwent breast screening with a combination of dose protocols, including standard full-field digital mammography, low-dose digital mammography, and digital breast tomosynthesis.  ... 
doi:10.1148/radiol.2016151749 pmid:27002418 pmcid:PMC4988904 fatcat:d4kii6inbfabneksjjiyegojpi

American College of Radiology/Society of Breast Imaging Curriculum for Resident and Fellow Education in Breast Imaging

Edward A. Sickles, Liane E. Philpotts, Brett T. Parkinson, Debra L. Monticciolo, Natalya M. Lvoff, Debra M. Ikeda, Maynard High, Dione Farria, Richard A. Carlson, Elizabeth S. Burnside, Lawrence W. Bassett, Jeffrey D. Allen (+5 others)
2006 Journal of the American College of Radiology  
-Film processing -Effect of screen-film speed, optical density, and film processing on radiation dose -High-intensity view boxes, view box masking • Full-field digital mammography -Characteristics of  ...  Several of the listed items involve aspects of breast imaging practice that are not universally available in either academic or community practice, for example, full-field digital mammography, computer-aided  ... 
doi:10.1016/j.jacr.2006.02.019 pmid:17412188 fatcat:paigiakq75cllfc4xrv63sahya

Accuracy of Breast Cancer Screening Using Film Mammography in Comparison to Digital Mammography

Lama Abed Abdullah Alorabi, Eman M. Algorashi
2018 The Egyptian Journal of Hospital Medicine  
This review aimed to compare the accuracy of screening using film mammography versus digital mammography in detection of breast cancer.  ...  Aim of the work: digital mammography may achieve better images than does film mammography in young women, especially those who are less than 50 years old, where breast is characterized by dense breast  ...  High density of breast tissues decreases the ability of mammography to detect breast lumps (10) and elevates the risk of breast cancer (11) .  ... 
doi:10.12816/0044848 fatcat:arwinv35s5a6nafdga45mz5kge

Digital Breast Tomosynthesis Versus Additional Diagnostic Mammographic Views for the Evaluation of Asymmetric Mammographic Densities

Hira Waheed, Imrana Masroor, Shaista Afzal, Muhammad Alvi, Syed Jahanzeb
2020 Cureus  
Tomosynthesis is subjectively preferred to conventional mammography and may offer superior diagnostic accuracy for the evaluation of breast lesions.  ...  For densities categorized as BIRADS-I (97) on additional view, digital breast tomosynthesis categorized 10 and 87 densities as BIRADS-0 and BIRADS-I, respectively.  ...  The radiation dose for a single tomosynthesis examination is comparable to or less than a full-field digital mammography examination [22] .  ... 
doi:10.7759/cureus.9637 pmid:32923238 pmcid:PMC7480781 fatcat:szvhu3b6w5flno2kaqz4txdgnu

Clinical performance of contrast-enhanced spectral mammography in pre-surgical evaluation of breast malignant lesions in dense breasts: a single center study

Anna Bozzini, Luca Nicosia, Giancarlo Pruneri, Patrick Maisonneuve, Lorenza Meneghetti, Giuseppe Renne, Andrea Vingiani, Enrico Cassano, Mauro Giuseppe Mastropasqua
2020 Breast Cancer Research and Treatment  
This open-label, single center, prospective study, included 160 dense breast women with at least one suspicious mammary lesion evaluated by ultrasound, full field digital mammography and magnetic resonance  ...  for full field digital mammography and 22.7% for magnetic resonance imaging (p = 0.02).  ...  Detection rate and size estimation in invasive tumors FFDM was not evaluable for 6 patients, CESM for 2 patients and MRI for 1 patient FFDM full field digital mammography, CESM contrast enhanced spectral  ... 
doi:10.1007/s10549-020-05881-2 pmid:32860166 fatcat:dwpjgvckyrbfjakcmi7pweg54q

A technique optimization protocol and the potential for dose reduction in digital mammography

Nicole T. Ranger, Joseph Y. Lo, Ehsan Samei
2010 Medical Physics (Lancaster)  
Digital mammography requires revisiting techniques that have been optimized for prior screen/film mammography systems.  ...  The objective of the study was to determine optimized radiographic technique for a digital mammography system and demonstrate the potential for dose reduction in comparison to the clinically established  ...  They also thank Thomas Mertelmeier of Siemens AG for many helpful discussions.  ... 
doi:10.1118/1.3276732 pmid:20384232 pmcid:PMC2830259 fatcat:dc6dnrkndbfkbhd7enszvd2kaa

Visualization of Breast Microcalcifications on Digital Breast Tomosynthesis and 2-Dimensional Digital Mammography Using Specimens

Jieun Byun, Jee Eun Lee, Eun Suk Cha, Jin Chung, Jeoung Hyun Kim
2017 Breast Cancer: Basic and Clinical Research  
PURPoSe: The purpose of this study is to compare the visibility of microcalcifications of digital breast tomosynthesis (DBT) and full-field digital mammography (FFDM) using breast specimens.  ...  The Fleiss kappa statistic for agreement among readers was 0.31.  ...  breast tomosynthesis; FFDM, full-field digital mammography.  ... 
doi:10.1177/1178223417703388 pmid:28469438 pmcid:PMC5391988 fatcat:m4mjewqoh5gujms5wstz6js2fa
« Previous Showing results 1 — 15 out of 1,303 results