Filters








71 Hits in 8.7 sec

Electromagnetic Imaging Methods for Nondestructive Evaluation Applications

Yiming Deng, Xin Liu
2011 Sensors  
Electromagnetic nondestructive tests are important and widely used within the field of nondestructive evaluation (NDE).  ...  the systems design and made the potential of electromagnetic NDE imaging seemingly unlimited.  ...  Further improvement on magneto-optic based imaging methods explored new sources of optical energy.  ... 
doi:10.3390/s111211774 pmid:22247693 pmcid:PMC3252010 fatcat:mtjxzhlge5hlpdnkq2zil6bz4q

2020 Index IEEE Transactions on Magnetics Vol. 56

2020 IEEE transactions on magnetics  
., +, TMAG Nov. 2020 4001405 Optical microscopy Use of a Micromagnetic Nondestructive Test in the Evaluation of the α'-Martensitic Transformation Generated in the Mechanical Fatigue Process of the AISI  ...  Sadiq, I., +, TMAG Aug. 2020 2200110 Coils An Improved F/C Structure for Cell-Scale Micro-Magnetic Coil.  ... 
doi:10.1109/tmag.2021.3050874 fatcat:tyv7g6ev3vbotdy7pt5u2aezqq

2013 Index IEEE Sensors Journal Vol. 13

2013 IEEE Sensors Journal  
The Author Index contains the primary entry for each item, listed under the first author's name.  ...  -that appeared in this periodical during 2013, and items from previous years that were commented upon or corrected in 2013.  ...  Dai, H., +, JSEN Sept. 2013 3193-3202 An Innovative Strategy for Correctly Interpreting Simultaneous Acquisition of EEG Signals and FMRI Images.  ... 
doi:10.1109/jsen.2013.2296364 fatcat:jlaitb4o6fdc5l7ihic4sg6xfu

2019 Index IEEE Transactions on Instrumentation and Measurement Vol. 68

2019 IEEE Transactions on Instrumentation and Measurement  
., +, TIM Oct. 2019 4112-4121 Active Microwave Thermography for Nondestructive Evaluation of Surface Cracks in Metal Structures.  ...  Pan, D., +, TIM Oct. 2019 3576-3588 Metals Active Microwave Thermography for Nondestructive Evaluation of Surface Cracks in Metal Structures.  ...  Image scanners Nonlinear Reconstruction of Multilayer Media in Scanning Microwave Microscopy. Wei, Z., +, TIM Jan. 2019 197-205  ... 
doi:10.1109/tim.2019.2956662 fatcat:kotlu7gwcngrdkelerc5va2hqe

2020 Index IEEE Transactions on Instrumentation and Measurement Vol. 69

2020 IEEE Transactions on Instrumentation and Measurement  
Converter Using All-Digital Nested Delay-Locked Loops With 50-ps Resolution and High Throughput for LiDAR TIM Nov. 2020 9262-9271 Helsen, J., see Huchel, L., TIM July 2020 4145-4153 Hemavathi, N.,  ...  of Rounds; TIM June 2020 3739-3749 Hendeby, G., see Kasebzadeh, P., TIM Aug. 2020 5862-5874 Heng, Y., see Xue, M., TIM June 2020 3812-3817 Henry, M.P., The Prism: Recursive FIR Signal Processing for  ...  ., +, TIM Feb. 2020 457-468 Synthetic Magnetic Field Imaging With Triangle Excitation Coil for Inspection of Any Orientation Defect.  ... 
doi:10.1109/tim.2020.3042348 fatcat:a5f4fsqs45fbbetre6zwsg3dly

Pipeline In-Line Inspection Method, Instrumentation and Data Management

Qiuping Ma, Guiyun Tian, Yanli Zeng, Rui Li, Huadong Song, Zhen Wang, Bin Gao, Kun Zeng
2021 Sensors  
Pipelines play an important role in the national/international transportation of natural gas, petroleum products, and other energy resources.  ...  In recent years, different non-destructive testing (NDT) methods have been developed for in-line pipeline inspection.  ...  Moreover, K-means, as an unsupervised method, has been applied for estimating the size of cracks in aircraft structures through Giant Magneto Resistance (GMR) sensing imaging data [159] .  ... 
doi:10.3390/s21113862 fatcat:fuzettw7ubeg7ecbom7imjuafe

News briefs

1993 Journal of Research of the National Institute of Standards and Technology  
diode lasers and the vaporcell magneto-optical trap, and speculates on future applications for this technology.  ...  NEW ALGORITHM SHARPENS IMAGES, DAMPS NOISE A NIST mathematician has developed an improved algorithm for reducing fuzziness and blur in digital images.  ... 
doi:10.6028/jres.098.037 fatcat:jzkjxok7z5ey3deqmbaifoilxq

Sensitive magnetometry in challenging environments [article]

Kai-Mei C. Fu, Geoffrey Z. Iwata, Arne Wickenbrock, Dmitry Budker
2020 arXiv   pre-print
This review discusses the ways in which various (predominantly optically-pumped) magnetometer technologies have been adapted for use in a wide range of noisy and physically demanding environments.  ...  State-of-the-art magnetic field measurements performed in shielded environments with carefully controlled conditions rarely reflect the realities of those applications envisioned in the introductions of  ...  The competitive edge of optically pumped magnetometers with respect to inductive eddy-current detection for nondestructive evaluation is the high sensitivity at low frequencies (high conductivity) and  ... 
arXiv:2008.00082v3 fatcat:k3qr2qtg5jchxhtwdlh3ddl26a

Table of contents

2008 IEEE transactions on magnetics  
Trapanese 3201 Magnetic Anisotropy Dispersion in CoPt Nanoparticles: An Evaluation Using the Néel Model F. Tournus, S. Rohart, and V.  ...  Kim 3083 Excitation and Imaging of Precessional Modes in Soft-Magnetic Squares A. Neudert, P. S. Keatley, V. V. Kruglyak, J. McCord, and R. J.  ...  Effect of van der Waals Forces in a Near Contact Head-Disk Interface  ... 
doi:10.1109/tmag.2008.2009197 fatcat:j5d24bhszvbghih7nnn3qiuihe

Conceptual design and multidisciplinary optimization of in-plane morphing wing structures

Daisaku Inoyama, Brian P. Sanders, James J. Joo, Douglas K. Lindner
2006 Smart Structures and Materials 2006: Modeling, Signal Processing, and Control  
Snap-through buckling is a step further in the direction of using non-linear mechanics for actuator design.  ...  An important aspect is the examination of buckling onset due to the excitation of piezoelectric elements, in a precompressed beam.  ...  They are finding significant use in embedded nondestructive evaluation for monitoring and analysis of civil, mechanical and aerospace systems.  ... 
doi:10.1117/12.658686 fatcat:rqnvt2atkjgnvpog5pivwjejzm

Nano Superconducting Quantum Interference device: A powerful tool for nanoscale investigations

Carmine Granata, Antonio Vettoliere
2016 Physics reports  
Indeed, magnetic imaging is a powerful tool for probing biological, chemical and physical systems.  ...  Among the different magnetic sensors, Superconducting QUantum Interference Devices (SQUIDs) exhibit an ultra high sensitivity and are widely employed in numerous applications.  ...  In medical imaging, for instance, single photons are detected in PET (Positron Emission Tomography) and CT (Computer Tomography) scanners and, more recently, in laser optical imaging.  ... 
doi:10.1016/j.physrep.2015.12.001 fatcat:tszoa2f7ibhgpfjxfwqoy7vz2y

Program Book

2008 2008 IEEE Ultrasonics Symposium  
fluid ejectors, and ultrasonic nondestructive evaluation, imaging and microscopy.  ...  of BPH: evaluation in a chronic canine model I Chang; Accord Optics, Sunnyvale, CA, USA.  ...  High Frame Rate Adaptive Imaging Using Coherence Factor Weighting and the MVDR Method 3K-5 Suppression of tissue-harmonics for pulse-inversion imaging using timereversal  ... 
doi:10.1109/ultsym.2008.2013 fatcat:blhyzvy55je6ne7e4npjomcd4u

Toward virtual biopsy through an all fiber optic ultrasonic miniaturized transducer: a proposal

A. Acquafresca, E. Biagi, L. Masotti, D. Menichelli
2003 IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control  
for experiments ........Design for manufacture ........Design for quality ........Design for testability ........Design standards ........Design tools ........Graphics ............Animation ..........  ...  vision ....Magnetic resonance imaging ........Diffusion tensor imaging ........Magnetic resonance elastography ....Magneto electrical resistivity imaging technique ....Microscopy ........Atomic force  ... 
doi:10.1109/tuffc.2003.1244749 fatcat:l3jre4etsvcqzfyz2jqggji3gy

Track I

2014 Biomedical Engineering  
The assessment of the cellularity in bone marrow is an essential step in diagnostic processes in pathology.  ...  We show that a properly designed and trained ESN is able to discriminate early and late granulopoietic cells in histopathological images of the human bone marrow with overall mean accuracy (±SD) of 0.846  ...  Biomed Acknowledgment: We thank Peter Erfurt, Hannover Medical School, Institute for Audioneurotechnology, for support in specimen and medium preparation.  ... 
doi:10.1515/bmt-2014-5008 pmid:25385893 fatcat:4o7vqkhdmfgk5fjzqpeh74x5te

Experimental Study on Residual Bending Strength of Corroded Reinforced Concrete Beam Based on Micromagnetic Sensor

Jianting Zhou, Junli Qiu, Yingxin Zhou, Yi Zhou, Runchuan Xia
2018 Sensors  
This paper presents a nondestructive test method to evaluate the residual bending strength of corroded reinforced concrete beam by analyzing the self-magnetic flux leakage (SMFL) signals.  ...  This work lays the foundation for evaluating the residual bending strength of corroded reinforced concrete beams using the SMFL signal; the micromagnetic sensor is further applied to the civil engineering  ...  popular, such as fiber optic coil winding [4] , fiber Bragg grating [5, 6] , laser scanning technology [7] , line scanning thermography (LST) [8, 9] , inductive thermography [10, 11] , optical excitation  ... 
doi:10.3390/s18082635 pmid:30103500 fatcat:k637j2pexnhdlg6aqjav265m2m
« Previous Showing results 1 — 15 out of 71 results