A copy of this work was available on the public web and has been preserved in the Wayback Machine. The capture dates from 2018; you can also visit the original URL.
The file type is application/pdf
.
Filters
Vertex-detector R&D for CLIC
2014
Journal of Instrumentation
In this paper the CLIC vertex-detector requirements are reviewed and the current status of R&D on sensors, readout and detector integration is presented. ...
The power dissipation of the readout chips is reduced by means of power pulsing, allowing for a cooling system based on forced gas flow. ...
They are integral parts of the full coverage tracking systems, designed to improve the accuracy of the track reconstruction, in particular for low transverse momenta. ...
doi:10.1088/1748-0221/9/03/c03026
fatcat:hz5pq2ef5vax5caps3257pmc2y
Snowmass 2021 White Paper Instrumentation Frontier 05 – White Paper 1: MPGDs: Recent advances and current R D
[article]
2022
arXiv
pre-print
, simulation, and uses in an expanding array of experimental configurations. ...
In this paper, we highlight high precision timing, high rate application, trigger capability expansion of the SRS readout system, and a structure designed for low ion backflow. ...
This does however not include the power-loss over cables, drop-off in voltage regulators and power for additional integrated logic like FPGAs, Flash devices, link drivers, sensors, monitoring ADCs and ...
arXiv:2203.06562v3
fatcat:gkbg42u47zbvpmorwujcrgz6ne
Elemental: An Open-Source Wireless Hardware and Software Platform for Building Energy and Indoor Environmental Monitoring and Control
2019
Sensors
and environmental monitoring solution, and (3) fault and anomaly detection and diagnostics of individual building systems at the zone-level. ...
This work demonstrates an open-source hardware and software platform for monitoring the performance of buildings, called Elemental, that is designed to provide data on indoor environmental quality, energy ...
Acknowledgments: We are grateful to the Center for REALTOR Technology (CRT) Labs team for facilitating and accelerating the development of this platform and providing technical support when needed. ...
doi:10.3390/s19184017
fatcat:vzvrrio2p5gphlv4s2xopgpz2u
Euphrates: Algorithm-SoC Co-Design for Low-Power Mobile Continuous Vision
[article]
2018
arXiv
pre-print
Measurement and synthesis results show that Euphrates achieves up to 66% SoC-level energy savings (4 times for the vision computations), with only 1% accuracy loss. ...
In this paper, we propose and develop an algorithm-architecture co-designed system, Euphrates, that simultaneously improves the energy-efficiency and performance of continuous vision tasks. ...
Adaptive Mode Compared to the baseline MDNet, the adaptive mode of Euphrates (EW-A) reduces energy by 31% with a small accuracy loss of 2%, similar to EW-4. ...
arXiv:1803.11232v1
fatcat:kil3eeq3vfa3tgimbc4h4zi5di
The design and performance of the ZEUS micro vertex detector
2007
Nuclear Instruments and Methods in Physics Research Section A : Accelerators, Spectrometers, Detectors and Associated Equipment
The barrel part of the detector is a 63 cm long cylinder with silicon sensors arranged around an elliptical beampipe. The forward part consists of four circular shaped disks. ...
In this report a detailed overview of the design and construction of the detector is given and the performance of the completed system is reviewed. ...
However, the many contributions of technicians and engineers from the collaborating insti- ...
doi:10.1016/j.nima.2007.08.167
fatcat:shnuwshtzzf4lflmdn54rtcwle
Caliste-SO: the x-ray spectrometer unit of the STIX instrument onboard the Solar Orbiter space mission
2014
High Energy, Optical, and Infrared Detectors for Astronomy VI
Caliste-SO is a hybrid detector integrating in a volume of 12 × 14 × 18 mm 3 a 1 mm-thick CdTe pixel detector, a frontend IDeF-X HD ASIC and passive parts to perform high resolution spectroscopy in the ...
Best pixels show an energy resolution of 0.7 keV FWHM at 6 keV (1 keV resolution requirement for STIX) and a low-level detection threshold below 3 keV (4 keV requirement for STIX). ...
The similar holding system for the CdTe pixel sensor is connected to an ASIC board and a full acquisition system is installed in the clean room to record 133 Ba spectra at -20°C. ...
doi:10.1117/12.2055171
fatcat:mre4mcq6tfc4tfffnytfzbkwky
Energy efficient heart rate sensing using a painted electrode ECG wearable
2017
2017 Global Internet of Things Summit (GIoTS)
ACKNOWLEDGMENTS This work was performed under the SPHERE IRC funded by the UK Engineering and Physical Sciences Research Council (EPSRC), Grant EP/K031910/1. ...
Note that this is the energy usage of the entire system, including the ECG front-end and IoT back-end. ...
System energy usage The energy usage of the system was determined by using the Texas Instruments INA226 Power Monitor. ...
doi:10.1109/giots.2017.8016260
dblp:conf/giots/KrachunovBCPFPC17
fatcat:3bxabohj4ffeborjs7uatd6wmu
The CMS fast beams condition monitor back-end electronics based on MicroTCA technology
2015
2015 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC)
The Fast Beams Condition Monitor (BCM1F), upgraded for LHC Run II, is one sub-system of the Beam Radiation Instrumentation and Luminosity Project of the CMS experiment. ...
It is based on 24 single crystal CVD diamond sensors. Each sensor is metallised with two pads, being read out by a dedicated fast frontend chip produced in 130 nm CMOS technology. ...
DETECTOR READOUT AND DATA TRANSMISSION Most of the particles hitting the sensors have an energy of a Minimum Ionizing Particle (MIP). ...
doi:10.1109/nssmic.2015.7581987
fatcat:r5vxka7difcg3hby5wjxuja54m
The Design, Construction, and Commissioning of the KATRIN Experiment
[article]
2021
arXiv
pre-print
In this paper, we document the current state of all completed beamline components (as of the first neutrino mass measurement campaign), demonstrate our ability to reliably and stably control them over ...
The KArlsruhe TRItium Neutrino (KATRIN) experiment, which aims to make a direct and model-independent determination of the absolute neutrino mass scale, is a complex experiment with many components. ...
The neutralization current is measured with an ADC 61, which achieves an
accuracy of about 3 % in the pA range [57, 116]. ...
arXiv:2103.04755v3
fatcat:2pzcedpzf5ebvoj4czcq6z5kmy
Scanning the Issue
2021
IEEE transactions on intelligent transportation systems (Print)
It reviews the state-of-the-art and state-of-the-practice (when applicable) of a multi-layer perception-planning-control architecture including on-board sensors and vehicular communications, the methods ...
An integer program with the objective of maximizing the police visibility rate and the additional constraint of response time guarantee is formulated to model the cityscale patrolling (CSP) problem. ...
Communicating the collected sensors-data to a central server has always been an issue due to the current GSM-R and LTE data-rate and spectrum limitations. ...
doi:10.1109/tits.2021.3052540
fatcat:wvccn3i32jdaxoov6mibk2tlku
Electronics for Fast Timing
[article]
2022
arXiv
pre-print
The ability to add a 4^th dimension to our measurements will help address the increasing complexity of events at hadron colliders and provide new tools for precise tracking and calorimetry for all experiments ...
Picosecond-level timing will be an important component of the next generation of particle physics detectors. ...
making this process an excellent candidate for highly integrated fast timing circuits. • 3D Integration(A.8) 3D integration of electronics (distinct from 3D sensor technology) is the interconnection of ...
arXiv:2204.00149v1
fatcat:ybnry2zah5e4dkxx7oe5v5cbna
Testing Lepton Flavor Universality and CKM Unitarity with Rare Pion Decays in the PIONEER experiment
[article]
2022
arXiv
pre-print
(Phase II) and an order of magnitude (Phase III). ...
Such precise measurements of BRPB will allow for tests of CKM unitarity in light of the Cabibbo Angle Anomaly and the theoretically cleanest extraction of |V_ud| at the 0.02% level, comparable to the deduction ...
The members of the collaboration are supported by the U.S. Department of Energy, Office of Science, Offices of High Energy Physics and Nuclear Physics; the U.S. ...
arXiv:2203.05505v1
fatcat:g56h5flknbeo3cermst7n3zcde
Technical design of the phase I Mu3e experiment
[article]
2021
arXiv
pre-print
on high-voltage monolithic active pixel sensors combined with scintillating fibres and tiles for precise timing measurements. ...
We present an overview of all aspects of the technical design and expected performance of the phase I Mu3e detector. ...
Acknowledgements We gratefully acknowledge the beamtimes provided by the following facilities: test beam facility at DESY Hamburg (Germany), a member of the Helmholtz Association (HGF), πM1 at Paul Scherrer ...
arXiv:2009.11690v2
fatcat:cpdzrhqnt5az5e6fgcocozk6za
Technical design of the phase I Mu3e experiment
2021
Nuclear Instruments and Methods in Physics Research Section A : Accelerators, Spectrometers, Detectors and Associated Equipment
on high-voltage monolithic active pixel sensors combined with scintillating fibres and tiles for precise timing measurements. ...
We present an overview of all aspects of the technical design and expected performance of the phase I Mu3e detector. ...
Acknowledgements We gratefully acknowledge the beamtimes provided by the following facilities: test beam facility at DESY Hamburg (Germany), a member of the Helmholtz Association (HGF), πM1 at Paul Scherrer ...
doi:10.1016/j.nima.2021.165679
fatcat:mkogr4bxvvce7ms7obpuhkp4em
Technical design of the phase I Mu3e experiment
2021
Nuclear instruments & methods in physics research / A 1014
high-voltage monolithic active pixel sensors combined with scintillating fibres and tiles for precise timing measurements. ...
We present an overview of all aspects of the technical design and expected performance of the phase I Mu3e detector. ...
Hesketh gratefully acknowledges the support of the Royal Society, UK through grant numbers UF140598 and RGF\EA\180081. ...
doi:10.3204/pubdb-2022-00370
fatcat:b3cwkavgyndzlbqrobnn6dykwa
« Previous