Filters








35 Hits in 8.4 sec

Linear and Nonlinear Electrochemical Impedance Spectroscopy Studies of Li/SOCl2 Batteries

Mohammed Ahmed Zabara, Can Berk Uzundal, Burak Ulgut
2019 Journal of the Electrochemical Society  
We present linear and stable data that is compatible with the Kramers-Kronig relations in frequency ranges as wide as 10 kHz to 1 mHz for fully charged to fully discharged cells.  ...  Moreover, we utilize Harmonic Analysis to study the nonlinearities in the measurement and further show that the passivation of the anode is a major cause for the nonlinearities.  ...  Figure 2 2 the top two diagrams (shown in a) are for low offset measurements with (−2mA DC, 1mA AC) for D-size cell and (−0.5mA DC, 0.2mA AC) for AA-size at 100% SoC.  ... 
doi:10.1149/2.1231904jes fatcat:eibxnu7nknfvpe3oe7pg6t65ia

Low-noise amplifiers in wireless communications: state of the art, two new wideband all-active LNAs in SiGe-BiCMOS

Balwant Godara, Alain Fabre
2009 Analog Integrated Circuits and Signal Processing  
And finally, it introduces a new class of LNAs, based on current conveyors, describing the founding principle and the performances of two new LNAs, one single-ended and the other differential.  ...  frequency responses from 0 to 3GHz; easy gain control over wide ranges (0 to 20dB).  ...  These introductory sections helped establish the specifications that would be required of a LNA for it to be suitable for transceivers treating different standards.  ... 
doi:10.1007/s10470-008-9272-8 fatcat:rre2gqcvnvf43nw6xcuy6r43pu

Optimal Low Power Complex Filters

Hussain A. Alzaher, Noman Tasadduq, Fares S. Al-Ammari
2013 IEEE Transactions on Circuits and Systems Part 1: Regular Papers  
Opamps are compensated for a signal pole response up to GBW to simplify their use in different applications.  ...  DC offset correction must be used to remove that DC component from L.O.  ...  the signal limitations are due to the node voltage (|VR|) and CA current (|ICA|).  ... 
doi:10.1109/tcsi.2012.2209293 fatcat:mgzi2mezmjhyhbxwuwwrpcjomm

Photoplethysmographic logger with contact force and hydrostatic pressure monitoring

P. Santos, V. Almeida, J. Cardoso, C. Correia
2013 2013 IEEE 3rd Portuguese Meeting in Bioengineering (ENBENG)  
xi Abstract Oxygen saturation ( ) is a key parameter for assessing a patient condition, mainly in critical care and anaesthesiology.  ...  This copy of the thesis has been supplied on condition that anyone who consults it is understood to recognize that its copyright rests with University of Coimbra and that no quotation from the thesis and  ...  It is also used to limit the current that passes through the FSR ® , which should not exceed 1mA/cm 2 of applied force.  ... 
doi:10.1109/enbeng.2013.6518437 fatcat:w4sn7uuiqndnxotyoakyyxynem

Single-Chip Scanning Probe Microscopes [chapter]

Neil Sarkar, Raafat R. Mansour
2015 Advanced Micro and Nanosystems  
Conventional SPMs suffer from several drawbacks owing to their large and bulky construction and to the use of piezoelectric materials.  ...  In addition to 3 DOF scanning, these devices possess integrated, thermally isolated temperature sensors to detect heat transfer in the tip-sample region.  ...  If multiple modes are of interest, each quantity must be calculated for each of the modes, and the models can be connected in parallel to the forcing sources.  ... 
doi:10.1002/9783527690237.ch9 fatcat:sl2exqkphjdvhjjt6fdgjouabu

Programming the Parallel Port: Interfacing the PC for Data Acquisition and Process Control

D V Gadre
2000 Measurement science and technology  
any voltage (AC or DC) as long as the relay contact can handle the voltage and the current.  ...  an ADC, andtransfers the ADC data over a suitable link to the host.  ...  The signals and their functions are: D0-D7 (I/O) The data bus. The 8-bit data bus is bidirectional and is used for data transfer from and to the adapter cards that fit into the card slots.  ... 
doi:10.1088/0957-0233/11/12/712 fatcat:osk66uo36rbw7k2cwgr32cuh7u

Performance of the CMS Tracker Optical Links and Future Upgrade Using Bandwidth Efficient Digital Modulation [article]

Stefanos Dris
2010 arXiv   pre-print
In order to preserve the large investments made for the current readout system, an upgrade path that involves reusing the existing optoelectronic components is considered.  ...  Corrective action was taken to reduce the gains and recover the lost dynamic range by lowering the optical receiver's load resistor value from 100Ω to 62Ω.  ...  This is well within reach of the LLD bias current range (up to ~55mA), and radiation-induced threshold increase can be compensated for.  ... 
arXiv:1004.5574v1 fatcat:3nntpro2rjfp3pd5v7eucqry2u

CONFIGURABLE ANALOG BUILDING BLOCKS FOR FIELD PROGRAMMABLE ANALOG ARRAYS

Osama Oglah
2004 unpublished
In this implementation and in order to have correct biasing conditions for all transistors, the input current must contain in addition to the AC component, a DC one.  ...  cells and thus are suitable for integration.  ...  Once again, the current multiplier is assumed to be built using the log and anti-log resources on the FPAA. The output current can be written as  ... 
fatcat:zttofqyucrhd5p5iv42kzmcn5q

Proceedings Of The 4Th Conference On Biomedical Applications Of Electrical Impedance Tomography: Abstracts [article]

William Lionheart, Richard Bayford
2003 Zenodo  
Abstracts from the 4th Conference on Biomedical Applications of Electrical Impedance Tomography held at the Department of Mathematics, University of Manchester Institute of Science and Technology (UMIST  ...  We report here on the measured voltage data for two subjects where the injected current was 1mA peak-to-peak at 9.6kHz. The subjects were fully awake.  ...  The patient interface has to be suitable for use in intensive care so electrode placement has to be speedy and the determination of electrode position made simple.  ... 
doi:10.5281/zenodo.17924 fatcat:iniab6q6dfcdxle4a325c5hp4e

A comparison of two EIT systems suitable for imaging impedance changes in epilepsy

L Fabrizi, A McEwan, T Oh, E J Woo, D S Holder
2009 Physiological Measurement  
a single standard mesh was used for all subjects and this may have introduced errors.  ...  However, most conventional robots are not suitable for intimate interaction with humans due to their hard and rigid bodies and inability to acquire sufficient contact information.  ...  Acknowledgements Acknowledgements This work was supported by the EPSRC under grants EP/E009697/1 and EP/E009158/1. The head mesh used in this study was originally developed by Dr. A.  ... 
doi:10.1088/0967-3334/30/6/s07 pmid:19491447 fatcat:nzeetw52ofaslcwhd2kxylvlpu

Test vehicle for a wafer-scale field programmable gate array

1997 Microelectronics and reliability  
This thesis investigates the use of Wafer Scale Technology to expand the size of FPGAs to 3 million gates for a 200mrn wafer.  ...  This currently limits the size of the circuits that can be implemented on a single FPGA to 40000 equivalent gates .  ...  The input current for the small chips was in the order of 360_2+ 0pA while running at 1kHz and 440-2+ 0pA at 1MHz.  ... 
doi:10.1016/s0026-2714(97)87833-x fatcat:mzzqdfnt35bjvh5b22l26rcvti

Test vehicle for a wafer-scale field programmable gate array

B. Dufort, G.H. Chapman
1995 IEEE Transactions on Components, Packaging, and Manufacturing Technology, Part B  
This thesis investigates the use of Wafer Scale Technology to expand the size of FPGAs to 3 million gates for a 200mrn wafer.  ...  This currently limits the size of the circuits that can be implemented on a single FPGA to 40000 equivalent gates .  ...  The input current for the small chips was in the order of 360_2+ 0pA while running at 1kHz and 440-2+ 0pA at 1MHz.  ... 
doi:10.1109/96.404099 fatcat:p57bnu56xbgxnkhrjtys3tz46m

Power management for a biotelemetry tag

Jianzhong Sun
2004
The supercapacitor is adopted for its highest volumetric efficiency among all capacitor technologies and relatively low leakage current, which is measured at 40°C and confirmed to be well under 0.5 μ A  ...  Two types of commercially available batteries, a silver oxide battery and a lithium manganese dioxide battery, are discharged at several constant current levels and at two different temperatures to establish  ...  ACKNOWLEDGEMENTS Sincere thanks are extended to the supervisor of this project, Dr. William G.  ... 
doi:10.14288/1.0099765 fatcat:bggp37w4ybfs7bzyq6da2yzsxu

Light Flicker and Harmonic Modelling of Electrical Lighting [article]

Lance Phillip Frater, University Of Canterbury
2015
The HSS is centred around linear time periodic (LTP) systems and the use of harmonic transfer functions to model the switching behaviour (including Switching Instant Variation (SIV)) of converters.  ...  This thesis develops an objective measurement method for light flicker, overcoming the limitations of the existing IEC flickermeter standard and develops models using the Harmonic State-Space (HSS) framework  ...  Alan, thank you for making it harder, and introducing me to frequency domain modelling and eventually the HSS.  ... 
doi:10.26021/1549 fatcat:dlrkzivtezgsjet4r5tmw4c4py

Alpha-particle monitoring systems based on a BJT detector on high-resistivity silicon

Davide Saguatti, Vladyslav Tyzhnevyi, Gabriele Giacomini
2011 2011 7th Conference on Ph.D. Research in Microelectronics and Electronics  
Using functional tests, we have shown that BJT detector operated with floating base can efficiently be used for the purpose of α-particle and, consequently, radon gas detection.  ...  Fabricated detectors observed high gain, low leakage currents and good detection properties.  ...  The current sweep had to be done from -1mA to 1mA; however, the voltage compliance of the source measurement unit 1 (SMU1) that forced current was immediately reached regardless of the value.  ... 
doi:10.1109/prime.2011.5966225 fatcat:ow2dgbyi7rfe3ab4mosrqewmvq
« Previous Showing results 1 — 15 out of 35 results