Stripped mirroring RAID architecture
2000
Journal of systems architecture
The disadvantage of RAID-1 lies in excessive redundancy, while the write performance of RAID-5 is only 1/4 of that of RAID-0. ...
In this paper, we propose a high performance and highly reliable disk array architecture, called stripped mirroring disk array (SMDA). It is a new solution to the small-write problem for disk array. ...
Modeling and performance evaluation In this section we present a utilization-based analytical model to compare the I/O access performance of RAID-0, RAID-1, RAID-5, RAID-10 and SMDA. ...
doi:10.1016/s1383-7621(99)00027-2
fatcat:qi4fne6nfngn5ep2z7epzlgbqi
HPDA: A hybrid parity-based disk array for enhanced performance and reliability
2010
2010 IEEE International Symposium on Parallel & Distributed Processing (IPDPS)
In this paper, we propose a Hybrid Parity-based Disk Array architecture, HPDA, which combines a group of SSDs and two hard disk drives (HDDs) to improve the performance and reliability of SSD-based storage ...
In HPDA, the SSDs (data disks) and part of one HDD (parity disk) compose a RAID4 disk array. ...
Menon [37] proposed a log-structured array (LSA) that combines LFS, RAID, compression and non-volatile cache to improve the write performance of RAID5. ...
doi:10.1109/ipdps.2010.5470361
dblp:conf/ipps/MaoJFWCZT10
fatcat:dlqcktbdn5dbrpg57u4le65ula
HPDA
2012
ACM Transactions on Storage
In this paper, we propose a Hybrid Parity-based Disk Array architecture, HPDA, which combines a group of SSDs and two hard disk drives (HDDs) to improve the performance and reliability of SSD-based storage ...
In HPDA, the SSDs (data disks) and part of one HDD (parity disk) compose a RAID4 disk array. ...
Menon [37] proposed a log-structured array (LSA) that combines LFS, RAID, compression and non-volatile cache to improve the write performance of RAID5. ...
doi:10.1145/2093139.2093143
fatcat:o5kxxlbuujf6lcj2rqnokztmje
The HP AutoRAID hierarchical storage system
1996
ACM Transactions on Computer Systems
In the lower level, RAID 5 parity protection is used to provide excel[ent storage cost for inactive data, at somewhat lower performance. ...
We describe the HP AUtORAID technology in detail, and provide performance data for an embodiment of it in a prototype storage array, together with the results of simulation studies used to choose algorithms ...
(This operation can take hours in a regular array.) Instead, all that is needed is for the controller's data structures to be updated. Log-structured RAID 5 writes. ...
doi:10.1145/225535.225539
fatcat:4uf3sntyavamfikfinwstuij6m
The HP AutoRAID hierarchical storage system
1995
ACM SIGOPS Operating Systems Review
In the lower level, RAID 5 parity protection is used to provide excel[ent storage cost for inactive data, at somewhat lower performance. ...
We describe the HP AUtORAID technology in detail, and provide performance data for an embodiment of it in a prototype storage array, together with the results of simulation studies used to choose algorithms ...
(This operation can take hours in a regular array.) Instead, all that is needed is for the controller's data structures to be updated. Log-structured RAID 5 writes. ...
doi:10.1145/224057.224065
fatcat:l44pfhcjsrg6dnsmb4urr6pmt4
The HP AutoRAID hierarchical storage system
1995
Proceedings of the fifteenth ACM symposium on Operating systems principles - SOSP '95
In the lower level, RAID 5 parity protection is used to provide excel[ent storage cost for inactive data, at somewhat lower performance. ...
We describe the HP AUtORAID technology in detail, and provide performance data for an embodiment of it in a prototype storage array, together with the results of simulation studies used to choose algorithms ...
(This operation can take hours in a regular array.) Instead, all that is needed is for the controller's data structures to be updated. Log-structured RAID 5 writes. ...
doi:10.1145/224056.224065
dblp:conf/sosp/WilkesGSS95
fatcat:oszqszuoefellpm72u75fnwthi
Parity Logging Overcoming the Small Write Problem in Redundant Disk Arrays
[chapter]
2009
High Performance Mass Storage and Parallel I/O
We provide a detailed analysis of parity logging and competing schemes -mirroring, floating storage, and RAID level 5 -and verify these models by simulation. ...
Parity logging provides performance competitive with mirroring, the best of the alternative single failure tolerating disk array organizations. ...
Section 9: Acknowledgments We would like to thank Ed Lee for the original version of Raidsim, and Brian Bershad, Peter Chen, Hugo Patterson, and Jody Prival for early reviews. ...
doi:10.1109/9780470544839.ch5
fatcat:m5rupf3runexrojq4bukwmpqkq
Parity logging overcoming the small write problem in redundant disk arrays
1993
SIGARCH Computer Architecture News
We provide a detailed analysis of parity logging and competing schemes -mirroring, floating storage, and RAID level 5 -and verify these models by simulation. ...
Parity logging provides performance competitive with mirroring, the best of the alternative single failure tolerating disk array organizations. ...
Section 9: Acknowledgments We would like to thank Ed Lee for the original version of Raidsim, and Brian Bershad, Peter Chen, Hugo Patterson, and Jody Prival for early reviews. ...
doi:10.1145/173682.165143
fatcat:kwzcc7k4p5csvnv7qaxrfdtqb4
Parity logging overcoming the small write problem in redundant disk arrays
1993
Proceedings of the 20th annual international symposium on Computer architecture - ISCA '93
We provide a detailed analysis of parity logging and competing schemes -mirroring, floating storage, and RAID level 5 -and verify these models by simulation. ...
Parity logging provides performance competitive with mirroring, the best of the alternative single failure tolerating disk array organizations. ...
Section 9: Acknowledgments We would like to thank Ed Lee for the original version of Raidsim, and Brian Bershad, Peter Chen, Hugo Patterson, and Jody Prival for early reviews. ...
doi:10.1145/165123.165143
dblp:conf/isca/StodolskyGH93
fatcat:5cbi4joiz5hv7doug26czq5fru
RAID-II
1994
SIGARCH Computer Architecture News
RAID-II runs Log-Structured File System (LFS) software to optimize performance for bandwidth-intensive applications. ...
In 1989, the RAID (Redundant Arrays of Inexpensive Disks) group at U. C. Berkeley built a prototype disk array called RAID-I. ...
Acknowledgments We would like to thank John Ousterhout for his suggestions for improving this paper and his participation in the development of RAID-II. ...
doi:10.1145/192007.192031
fatcat:3eb2plwq7zgdpa4arp3tiu34ue
RAID6L: A log-assisted RAID6 storage architecture with improved write performance
2011
2011 IEEE 27th Symposium on Mass Storage Systems and Technologies (MSST)
We present a detailed comparison between RAID6L and Parity Logging, and show that RAID6L has several advantages over Parity Logging. ...
In this paper, we propose a log-assisted RAID6 architecture, called RAID6L, to boost the write performance of the RAID6 systems. ...
Hash List Structure The structure of the Hash list is shown in Figure 2 . The hash list is composed of a table head array and several entry lists. ...
doi:10.1109/msst.2011.5937230
dblp:conf/mss/JinFJT11
fatcat:67vewiv7pfesrhc3p4enhzszie
RAIDII: A HighBandwidth Network File Server
[chapter]
2009
High Performance Mass Storage and Parallel I/O
RAID-II runs the Log-Structured File System (LFS) to optimize the performance of the disk array for bandwidth-intensive applications. ...
In 1989, the RAID group at U. C. Berkeley built a prototype disk array called RAID-I. ...
Acknowledgments We w ould like to thank the other members of the RAID and Sprite groups at Berkeley for their con- ...
doi:10.1109/9780470544839.ch26
fatcat:c5glbrqcljedrkytafgfigfccm
The HP AutoRAID Hierarchical Storage System
[chapter]
2009
High Performance Mass Storage and Parallel I/O
In the lower level, RAID 5 parity protection is used to provide excellent storage cost for inactive data, at somewhat lower performance. ...
Con@uring redundant disk arrays is a black art. To configure an array properly, a system administrator must understand the details of both the array and the workload it will support. ...
They developed the HP AutoRAID system architecture and the product version of the controller and were the customers for our performance and algorithm studies. ...
doi:10.1109/9780470544839.ch7
fatcat:ydqowocgevd2dcqimgy2axwj5q
A new high-performance, energy-efficient replication storage system with reliability guarantee
2012
012 IEEE 28th Symposium on Mass Storage Systems and Technologies (MSST)
It employs a parity software RAID as a virtual write buffer disk at the front end to absorb new writes. ...
This paper develops PERAID, a new high-performance, energy-efficient replication storage system, which aims to improve both performance and energy efficiency without compromising reliability. ...
In 1995, Log-structured Array [16] was proposed which combines LFS, RAID5 and a non-volatile cache. ...
doi:10.1109/msst.2012.6232373
dblp:conf/mss/WanYWX12
fatcat:ndbblh3hfncgnafgg4s3wk7csi
HiSMRfs: A high performance file system for shingled storage array
2014
2014 30th Symposium on Mass Storage Systems and Technologies (MSST)
Metadata is managed using in-memory tree structures and stored in a high performance random write area such as in a SSD. ...
Data writing is done through sequential appending style and store in a SMR drive. HiSMRfs includes a file/object-based RAID module for SMR/HDD arrays. ...
Fig. 1 . 1 Data Management Layer for SMR
Fig. 3 . 3 Architecture of HiSMRfs
Fig. 4 4 Fig. 4. Metadata Structure
Fig. 5 . 5 Structure of RAID in HiSMRfs
Fig. 9 . 9 Fig. 9.
TABLE I . ...
doi:10.1109/msst.2014.6855539
dblp:conf/mss/JinXCHL14
fatcat:kw3umzjt6rhvlki62jdai5c5za
« Previous
Showing results 1 — 15 out of 3,204 results