Filters








2,386,417 Hits in 3.8 sec

A Novel Range Test [chapter]

Kun Peng, Colin Boyd, Ed Dawson, Eiji Okamoto
2006 Lecture Notes in Computer Science  
In a range test, one party holds a ciphertext and needs to test whether the message encrypted in the ciphertext is within a certain interval range.  ...  In this paper, a range test protocol is proposed, where the party holding the ciphertext asks another party holding the private key of the encryption algorithm to help him.  ...  When the precise range test outputs TRUE, A 2 's only knowledge is the result of the precise range test without A 1 's collusion as the precise range test outputs TRUE if and only if both basic range tests  ... 
doi:10.1007/11780656_21 fatcat:o2xbphqknrbcpifknyc2kdfq7m

Development of a novel home sperm test - temperature range

Jaroslav J. Marik
2006 Human Reproduction  
a selected population of poor responders with ovarian deficiency.  ...  These data do not exclude any positive effect in patients with a less-severe ovarian deficiency.  ...  novel home sperm test -temperature range Sir, I have read with great interest the publication of Björndahl  ... 
doi:10.1093/humrep/del060 pmid:17035549 fatcat:il5pdapvszd2fdqc52mllsmrne

Reply: Development of a novel home sperm test - temperature range

Lars Björndahl, Tom Connelly, Jackson Kirkman-Brown, Christopher Barratt
2006 Human Reproduction  
a selected population of poor responders with ovarian deficiency.  ...  These data do not exclude any positive effect in patients with a less-severe ovarian deficiency.  ...  E-mail: c.barratt@bham.ac.uk doi:10.1093/humrep/del061 Development of a novel home sperm test -What are the limitations?  ... 
doi:10.1093/humrep/del061 fatcat:2tyewxcpn5gonou6xd57gtsd3e

A Novel Two-Step Laser Ranging Technique for a Precision Test of the Theory of Gravity

Konstantin Penanen, Talso Chui
2004 Nuclear Physics B - Proceedings Supplements  
We describe a novel two-step laser ranging technique, which largely eliminates the effects of non-gravity acceleration sources and enables celestial mechanics checks with unprecedented precision.  ...  Since dark matter dominates the galactic acceleration, DMX can also test whether dark matter obeys the equivalence principle to a level of 100 ppm by ranging to several proof masses of different composition  ...  Science return of such measurements include tests of strong equivalence principle (Lunar Laser Ranging (LLR), [1,2]) and general relativity tests (LAGEOS series [3] ).  ... 
doi:10.1016/j.nuclphysbps.2004.08.033 fatcat:hq6a7gk6jjgpdfw4awsqxgr24y

A novel variable-distance antenna test range and high spatial resolution corroboration of the inverse square law for 433.5 MHz radiation [article]

Christoph de Haën, Giancarlo Baldini, Matthias Erhardt
2015 arXiv   pre-print
A novel, low-budget, open-air, slant-geometry antenna test range for UHF radiation is presented.  ...  In support of the validity of the range the inverse square law for 433.5 MHz radiation between two naked half-wave dipole antennas was tested with high spatial resolution from close to the far field limit  ...  The novel test range allows repeated and highly reproducible movement of R between any chosen measurement position and the bottom one.  ... 
arXiv:1508.05932v3 fatcat:srcqrnd4wjhgfbqgp5ce4ovjay

A Novel Method for Testing Digital to Analog Converter in Static Range

Hariharan
2010 American Journal of Applied Sciences  
Approach: A slope generator (more commonly known as integrator) produces a Ramp type of output voltage when it is fed with a DC voltage, slope of ramp depends upon the magnitude of DC-voltage.  ...  This research aims to optimize and simplify the design of DAC testing scheme, while minimizing the computational overhead. Henceforth, the testing technique can be brought on to BIST level circuitry.  ...  INTRODUCTION A novel test scheme for Digital-to-Analog Converter (DAC) is presented.  ... 
doi:10.3844/ajassp.2010.1157.1163 fatcat:hvntqk3iuve45fdhb2crdnsqeq

Range of Motion Testing of a Novel 3D-Printed Synthetic Spine Model

Michael A. Bohl, Sarah McBryan, Anna G. U. S. Newcomb, Jennifer N. Lehrman, Brian P. Kelly, Peter Nakaji, Steve W. Chang, Juan S. Uribe, Jay D. Turner, U. Kumar Kakarla
2019 Global Spine Journal  
The purpose of this study was to investigate the performance of the current generation of BBS models on biomechanical testing of range of motion (ROM) and axial compression and to compare the performance  ...  of these models to historical cadaveric data acquired using the same testing protocol.  ...  Declaration of Conflicting Interests Author MAB is the inventor on a patent filing describing the technology evaluated in this study.  ... 
doi:10.1177/2192568219858981 pmid:32435561 pmcid:PMC7222693 fatcat:gcljve3t5bezjgwufamqkkc7hq

High Dynamic Range Bacterial Cell Detection in a Novel "Lab-In-A-Comb" for High-Throughput Antibiotic Susceptibility Testing of Clinical Urine Samples [article]

Jeremy Pivetal, Martin J. Woodward, Nuno M. Reis, Alexander D. Edwards
2017 bioRxiv   pre-print
We evaluated for the first time how pathogen concentration in urine affects microfluidic AST using a novel microplate compatible high throughput microfluidic AST system termed Lab-on-a-Comb.  ...  Although microfluidic technology can miniaturise AST, the high dynamic range of pathogen density found in clinical urine samples makes direct testing of clinical samples, rather than testing colonies from  ...  There remains an urgent need for novel AST methods that can directly test patient urine and avoid overnight plating.  ... 
doi:10.1101/199505 fatcat:3lohfmjcgzfcthektsasdqgchy

THE RELIABILITY OF A NOVEL HEEL-RISE TEST VERSUS GONIOMETRY TO ASSESS PLANTARFLEXION RANGE OF MOTION

Brandon M Ness, Ramu G Sudhagoni, Hanz Tao, Olivia R Full, Lucas O Seehafer, Chelsie M Walder, Kory Zimney
2018 International Journal of Sports Physical Therapy  
Ankle plantarflexion (PF) active range of motion (ROM) is traditionally assessed in a non-weight-bearing (NWB) position with a universal goniometer.  ...  Two physical therapy student examiners, blinded to each other's measurements, assessed PF active ROM through a NWB goniometric technique and a FHRT on all subjects within the same test session.  ...  The purpose of this study was to explore the intra-and interrater reliability of a novel, functional heel-rise test (FHRT) performed in WB to examine active ROM when compared to a NWB technique with a  ... 
pmid:29484238 pmcid:PMC5808010 fatcat:23t3tzfllreqbdg3r3ufr46alq

Construction and testing of a novel host-range defective myxoma virus vaccine with the M063 gene inactivated that is non-permissive for replication in rabbit cells

Mathew M. Adams, Barbara H. van Leeuwen, Grant McFadden, Peter J. Kerr
2008 Veterinary Research  
A targeted M063 deletion mutant was constructed in the attenuated Uriarra strain of myxoma virus and the ability of this virus to act as a safe, non-transmissible vaccine against myxomatosis was tested  ...  Targeted host-range gene deletions could have potential for rapid development of poxvirus vaccines in general. myxomatosis / vaccine / host-range / poxvirus / rabbits Article available at  ...  The myxoma virus early gene M063 is a host-range gene essential for productive replication of the virus in primary rabbit cells and in all rabbit cell lines tested in vitro [3] .  ... 
doi:10.1051/vetres:2008037 pmid:18778680 fatcat:hqvgmcijjfgizauxn36kvjkzui

Concurrent validity and reliability of measuring range of motion during the cervical flexion rotation test with a novel digital goniometer

Kerstin Luedtke, Thomas Schoettker-Königer, Toby Hall, Christine Enns, Maike Grassold, Petra Hasselhoff-Styhler, Christian Neulinger, Max Obrocki, Philipp Przyhoda, Axel Schäfer
2020 BMC Musculoskeletal Disorders  
The flexion rotation test (FRT) is a commonly used diagnostic test to detect upper cervical movement impairment.  ...  Two separate cross-sectional studies were conducted using the digital goniometer EasyAngle (Meloq AB, Stockholm, Sweden) for a) investigating the concurrent validity of upper cervical range of motion (  ...  One of the best evaluated tests for this purpose is the flexion-rotation-test (FRT), which investigates primarily the range of motion (ROM) between the C1 and C2 vertebrae [4] [5] [6] [7] [8] [9] .  ... 
doi:10.1186/s12891-020-03525-6 pmid:32781990 fatcat:joctub4p4vfuxks4aye62kdofq

Validity and Test-Retest Reliability of a Novel Push Low-Cost Hand-Held Dynamometer for Knee Strength Assessment during Different Force Ranges

Maria de Cássia Macedo, Matheus Almeida Souza, Kariny Realino Ferreira, Laura Oliveira Campos, Igor Sérgio Oliveira Souza, Michelle Almeida Barbosa, Ciro José Brito, Leonardo Intelangelo, Alexandre Carvalho Barbosa
2022 Diagnostics  
The objective was to assess the instrumental validity and the test–retest reliability of a low-cost hand-held push dynamometer adapted from a load-cell based hanging scale (tHHD) to collect compressive  ...  The ICC and the Cronbach's α showed excellent consistency and agreement for both instrumental validity and test–retest reliability (range: 0.89–0.99), as the correlation and determination coefficients  ...  Four beams in the corner were used to measure the vertical force (range: −1100 N to +4400 N) and a 5th beam measured the force in a parallel axis (range: −1100 N to +1100 N).  ... 
doi:10.3390/diagnostics12010186 pmid:35054353 pmcid:PMC8774426 fatcat:uxnq2qkt5fbdvnljrmzxe6jug4

Development of Broth Microdilution MIC and Disk Diffusion Antimicrobial Susceptibility Test Quality Control Ranges for the Combination of Cefepime and the Novel β-lactamase Inhibitor Enmetazobactam

Adam Belley, Michael D. Huband, Kelley A. Fedler, Amy A. Watters, Robert K. Flamm, Stuart Shapiro, Philipp Knechtle
2019 Journal of Clinical Microbiology  
Enmetazobactam (formerly AAI101) is a novel penicillanic sulfone β-lactamase inhibitor active against a wide range of ESBLs.  ...  Enmetazobactam was tested at a fixed concentration of 8 μg/ml in the MIC assay, and a cefepime-enmetazobactam disk mass of 30/20 μg was used in the disk diffusion assay.  ...  Testing was performed over a minimum of 3 days, with no more than four replicates tested per day.  ... 
doi:10.1128/jcm.00607-19 pmid:31167844 pmcid:PMC6663906 fatcat:anzalwlg45cr5bekawulcfv6ke

Analysis of a novel field dilution method for testing samples that exceed the analytic range of point-of-care blood lead analyzers

Antonio James Neri, Joannie Roy, Jeffery Jarrett, Yi Pan, Carrie Dooyema, Kathleen Caldwell, Nasir Tsafe Umar-Tsafe, Ruth Olubiyo, Mary Jean Brown
2013 International Journal of Environmental Health Research  
Brown (2014) Analysis of a novel field dilution method for testing samples that exceed the analytic range of point-of-care blood lead analyzersInvestigators developed and evaluated a dilution method for  ...  Having health care workers with limited experience operating in a low-resource setting implement a novel method in the field laboratory may have introduced some operator errors.  ...  These results indicate that a reliable field-based blood lead testing program utilizing the dilution procedure is achievable.  ... 
doi:10.1080/09603123.2013.857390 pmid:24266724 fatcat:a4akor4n3jazreto5pq4vwgdtq

A novel use of inertial sensors to measure the craniocervical flexion range of motion associated to the craniocervical flexion test: an observational study

Tomás Pérez-Fernández, Susan Armijo-Olivo, Sonia Liébana, Pablo José de la Torre Ortíz, Josué Fernández-Carnero, Rafael Raya, Aitor Martín-Pintado-Zugasti
2020 Journal of NeuroEngineering and Rehabilitation  
Background The craniocervical flexion test (CCFT) is recommended when examining patients with neck pain related conditions and as a deep cervical retraining exercise option.  ...  The objectives of our study were (1) to measure craniocervical flexion range of motion (ROM) associated with each stage of the CCFT using a wearable inertial sensor and to determine the reliability of  ...  A flowchart of the whole testing protocol is shown in Fig. 2 .  ... 
doi:10.1186/s12984-020-00784-1 pmid:33213452 pmcid:PMC7678052 fatcat:nrzsdfvxefhfjk3m5x7q6phk54
« Previous Showing results 1 — 15 out of 2,386,417 results