Filters








2,432 Hits in 6.6 sec

3D Coronary Vessel Tracking in X-Ray Projections [chapter]

Emmanuelle Poulain, Grégoire Malandain, Régis Vaillant
2017 Lecture Notes in Computer Science  
Here, we propose a 3D/2D temporal tracking of one coronary vessel, based on a spline deformation, using pairings with a controlled 2D stretching or contraction along the paired curves and a preservation  ...  of the length of the 3D curve.  ...  in the x-ray projections.  ... 
doi:10.1007/978-3-319-59448-4_20 fatcat:6fcfqsusovcelocabypid32wdu

3D Coronary Vessel Tree Tracking in X-Ray Projections [chapter]

Emmanuelle Poulain, Grégoire Malandain, Régis Vaillant
2019 Lecture Notes in Computer Science  
the tree-spline and the observed x-ray projection of the coronary arteries.  ...  It comes with the challenge of registering this 3D modality to the projection of the coronary arteries which are deforming with the cardiac motion.  ...  Even if the 3D model of the coronary vessels can be depicted by a tree, this may not be the case for the x-ray projection. Indeed, self superimpositions create crossings.  ... 
doi:10.1007/978-3-030-21949-9_42 fatcat:kb4lgcgu3vdvvgsezjzcrqpw34

A Deformation Tracking Approach to 4D Coronary Artery Tree Reconstruction [chapter]

Yanghai Tsin, Klaus J. Kirchberg, Guenter Lauritsch, Chenyang Xu
2009 Lecture Notes in Computer Science  
This paper addresses reconstruction of a temporally deforming 3D coronary vessel tree, i.e., 4D reconstruction from a sequence of angiographic X-ray images acquired by a rotating C-arm.  ...  Driven by gradient vector flow (GVF) fields, the method then estimates deformation such that projections of deformed models align with X-ray images of corresponding cardiac phases.  ...  Since we track deformations of the 3D coronary tree, this is a 4D reconstruction by deformation tracking approach.  ... 
doi:10.1007/978-3-642-04271-3_9 fatcat:onfbzu4qcnhfrpzry2dmm6jp7a

Simulation Environment for the Evaluation of 3D Coronary Tree Reconstruction Algorithms in Rotational Angiography

G. Yang, A. Bousse, C. Toumoulin, H. Shu
2007 IEEE Engineering in Medicine and Biology Society. Conference Proceedings  
and the calculation of radiographic projections of the 3D model of coronary tree throughout several cardiac cycles.  ...  We present a preliminary version of a simulation environment to evaluate the 3D reconstruction algorithms of the coronary arteries in rotational angiography.  ...  The tracking algorithm relies on a local modeling of the vessel by a cylinder in a 3D homogeneous space.  ... 
doi:10.1109/iembs.2007.4353335 pmid:18003001 pmcid:PMC2134976 fatcat:hnlojfrx3fhybfu4b4jk6u4raq

Automatic Heart Peripheral Vessels Segmentation Based on a Normal MIP Ray Casting Technique [chapter]

Charles Florin, Romain Moreau-Gobard, Jim Williams
2004 Lecture Notes in Computer Science  
Ultimately, the vessels centerline points are detected using a vessel tracking algorithm, and linked together to form a complete coronary artery tree.  ...  This paper introduces a new technique to detect the coronary arteries as well as other heart's peripheral vessels.  ...  During the next step, the ray collection in 3D is used as a pre-segmentation tool. Each vessel crossed by a ray generates a peak of intensity on the ray's profile curve.  ... 
doi:10.1007/978-3-540-30135-6_59 fatcat:ncmjb2sjjjdkjgzotz6vszjquy

A parallelized 4D reconstruction algorithm for vascular structures and motions based on energy optimization

Xinglong Liu, Fei Hou, Aimin Hao, Hong Qin
2014 The Visual Computer  
In this paper, we present a parallel 4D vessel reconstruction algorithm that simultaneously recovers 3D structure, shape, and motion based on multiple views of X-ray angiograms.  ...  We demonstrate our system in coronary arteries reconstruction and movement tracking for percutaneous coronary intervention surgery to help medical practitioners learn about the 3D shapes and their motions  ...  [32] presented a 3D method for tracking the coronary arteries through a temporal sequence of biplane X-ray angiograms.  ... 
doi:10.1007/s00371-014-1024-4 fatcat:l7vrlgdnbzd75boxjf557djxbi

Efficient 3D Reconstruction of Vessels from Multi-views of X-Ray Angiography

Xinglong Liu, Fei Hou, Shuai Li, Aimin Hao, Hong Qin
2013 2013 International Conference on Computer-Aided Design and Computer Graphics  
To overcome these shortcomings, we develop an efficient vessel reconstruction system based on multiple X-Ray views.  ...  MOTIVATION Intra-operative X-Ray is essential during some surgeries, such as percutaneous coronary intervention.  ...  D. 3D reconstruction of coronary arteries. In our method, we treat the space between the image intensifier and the optical center of the X-Ray machine as an Markov Random Field.  ... 
doi:10.1109/cadgraphics.2013.68 dblp:conf/cadgraphics/LiuHLHQ13 fatcat:rsh4i6mjovatrm5l5wduulgcze

3D+t Modeling of Coronary Artery Tree from Standard Non Simultaneous Angiograms [chapter]

Fabien Mourgues, Frédéric Devernay, Grégoire Malandain, Ève Coste-Manière
2001 Lecture Notes in Computer Science  
Finally 3D sections are estimated from the projected sections.  ...  3D models of coronary arteries is a valuable help for the planning and simulation of minimally-invasive cardiac surgery, and may be used in per-operative augmented reality.  ...  Acknowledgments We would like to thank Régis Vaillant from GE Medical Systems, Global X-Ray Advanced Applications, and Didier Blanchard from Georges Pompidou European Hospital for their help in providing  ... 
doi:10.1007/3-540-45468-3_213 fatcat:x6wkxo3sfbbffped5a66uu4slq

Fast Temporal Tracking and 3D Reconstruction of a Single Coronary Vessel

Ifeoma Nwogu, Liana Lorigo
2007 2007 IEEE International Conference on Image Processing  
We have developed a fast and accurate method for extracting and tracking intravascular imaging data from X-ray angiograms.  ...  Vessel extraction and vessel motion estimation from X-ray angiograms has been a challenging computer vision problem for several years.  ...  BACKGROUND AND PURPOSE With the wide availability and utility of X-ray coronary angiography, it is still very important to continue to investigate methods to improve coronary disease analysis using X-rays  ... 
doi:10.1109/icip.2007.4379884 dblp:conf/icip/NwoguL07 fatcat:cbpfuwaclrgclhwgb25xkauiwa

Automatic determination of optimal view for the visualization of coronary lesions by rotational X-ray angiography

H. Feuillâtre, B. Sanokho, J.-C. Nunes, M. Bedossa, C. Toumoulin
2013 IRBM  
We consider that a dynamic sequence of 3D coronary tree is available either from pre-segmented CT data or by reconstruction of the 3D coronary tree from the projections acquired at each phase of the cardiac  ...  We proceed by volume projection into the detector plane in all possible gantry orientations.  ...  INTRODUCTION X-ray angiography plays a prominent role in the treatment of cardiovascular diseases [1] .  ... 
doi:10.1016/j.irbm.2013.08.004 fatcat:ckdrubtplfhj5mhvbgg2x73d2a

Three-dimensional reconstruction of stenosed coronary artery segments with assessment of the flow impedance

A. A. Hulzebosch, C. H. Slump, M. A. Viergever
1990 International Journal of Cardiac Imaging  
One approach is to assume a circular cross-section of the coronary artery. Hence, the diameter is estimated from the contours of the vessels in both projections.  ...  In this paper preliminary results of a study about the diagnostic benefits of 3D visualization and quantitation of stenosed coronary artery segments are presented.  ...  The axis of the vessel segment, therefore, should not be parallel to one of the X-ray beams.  ... 
doi:10.1007/bf01833982 pmid:2230291 fatcat:suto7dkmvraxfmo4daox25s4we

Comparison of X-ray fluoroscopy and interventional magnetic resonance imaging for the assessment of coronary artery stenoses in swine

Jordin D. Green, Reed A. Omary, Brian E. Schirf, Richard Tang, Biao Lu, James A. Gehl, J. Jenny Huang, James C. Carr, F. Scott Pereles, Debiao Li
2005 Magnetic Resonance in Medicine  
This study demonstrates that in the future interventional MRI may be an alternative to X-ray angiography for the detection and quantification of coronary artery disease.  ...  The accuracy of a two-step interventional MRI protocol to quantify coronary artery disease was compared to the clinical gold standard, X-ray angiography.  ...  X-ray imaging of the left coronary artery was performed in frontal, 55° left anterior oblique, and 30° right anterior oblique projections using iodinated contrast agent.  ... 
doi:10.1002/mrm.20699 pmid:16217784 pmcid:PMC1343514 fatcat:4jrvyxs5zndenjta3idi73ayt4

Temporal tracking of 3D coronary arteries in projection angiograms

Guy Shechter, Frederic Devernay, Eve Coste-Maniere, Elliot R. McVeigh, Milan Sonka, J. Michael Fitzpatrick
2002 Medical Imaging 2002: Image Processing  
on arterial length and regularity, which lack meaning in 2D projection space, are directly applicable in 3D; and (3) tracking arterial segments through occlusions and crossings in the projection images  ...  A method for 3D temporal tracking of a 3D coronary tree model through a sequence of biplane cineangiography images has been developed.  ...  Khaled Abdul-Nour, Bill Schenke, Stan White, Gloria Zalos, and other members of the Cardiac Catheterization Section of the National Heart Lung and Blood Institute, NIH, for their assistance in obtaining  ... 
doi:10.1117/12.467204 dblp:conf/miip/ShechterDCM02 fatcat:ajpzxqx775aclo5ys5mgsa6xaa

Registration of $3{\rm D}+{\rm t}$ Coronary CTA and Monoplane $2{\rm D}+{\rm t}$ X-Ray Angiography

C. T. Metz, M. Schaap, S. Klein, N. Baka, L. A. Neefjes, J. Schultz, W. J. Niessen, T. van Walsum
2013 IEEE Transactions on Medical Imaging  
Evaluation was performed on 26 datasets of 17 patients by comparing projected model centerlines with manually annotated centerlines in the X-ray images.  ...  A method for registering preoperative 3D+t coronary CTA with intraoperative monoplane 2D+t X-ray angiography images is proposed to improve image guidance during minimally invasive coronary interventions  ...  ACKNOWLEDGMENT This work was financially supported by ITEA project 09039, Mediate.  ... 
doi:10.1109/tmi.2013.2245421 pmid:23392343 fatcat:3imdyy556fcu7bqdu256u4xphi

Toward MRI-guided coronary catheterization: Visualization of guiding catheters, guidewires, and anatomy in real time

Jean-Michel Serfaty, Xiaoming Yang, Pelin Aksit, Harald H. Quick, Meiyappan Solaiyappan, Ergin Atalar
2000 Journal of Magnetic Resonance Imaging  
The success of x-ray fluoroscopy-guided coronary catheterization depends in part on the ability to obtain simultaneous and real-time visualization of the guidewire, guiding catheter, and anatomy of the  ...  Real-time projection images of the chest anatomy, together with the guidewire and guiding catheter, were obtained.  ...  It was not possible, as with x-ray fluoroscopy, to visualize the vessels after injection of contrast media in the MRI guiding catheter.  ... 
doi:10.1002/1522-2586(200010)12:4<590::aid-jmri11>3.0.co;2-3 pmid:11042641 fatcat:khf6zq3zhjhodk54vrhoeujbzq
« Previous Showing results 1 — 15 out of 2,432 results