The Effect of Fine needle aspiration on Detecting Malignancy in Thyroid Nodule release_en73fkbmobh6bjhdyco643rbei

by Hamid reza Hemmati, Banafshe Shahnazari, Majid Foroutan

Published in Biomolecular Concepts by Walter de Gruyter GmbH.

2019   Volume 10, Issue 1, p99-105

Abstract

<jats:title>Abstract</jats:title> <jats:sec id="j_bmc-2019-0012_s_007"> <jats:title id="d3841701e42430">Introduction</jats:title> The prevalence of thyroid nodules is 4-7% in adults. Although less than 5% of nodules in adults are malignant, most nodules are non-neoplastic or benign. Fine needle aspiration (FNA) is a diagnostic technique for evaluation of non-toxic nodules, which has been widely accepted. Its primary objective is the patient triage in order to identify those who need surgery and aid in the decision of the appropriate surgical procedures.</jats:sec> <jats:sec id="j_bmc-2019-0012_s_008"> <jats:title id="d3841701e42438">Materials and Methods</jats:title> This retrospective study was conducted on 116 patients who underwent thyroidectomy in Semnan's Kowsar Hospital during 2011-2018 in Iran. The data were recorded before and after the surgery in the checklist. The data were compared and the sensitivity, specificity and diagnostic accuracy of FNA were calculated. Data were analyzed by SPSS software (version 18.0) and analyzed by Chi-Square test and Independent Samples test.</jats:sec> <jats:sec id="j_bmc-2019-0012_s_009"> <jats:title id="d3841701e42446">Results</jats:title> The sensitivity of FNA was 96.9%; its specificity was 81.7%; its positive predictive value (PPV) was 73.8%; its negative predictive value (NPV) was 98%; and its diagnostic accuracy was 86.9%. For the nodules smaller than 4 cm, FNA was calculated with higher sensitivity, specificity, PPV, NPV, and diagnostic accuracy compared to nodules larger than 4 cm.</jats:sec> <jats:sec id="j_bmc-2019-0012_s_010"> <jats:title id="d3841701e42457">Conclusion</jats:title> FNA is a reliable screening method for preoperative assessment that can accurately detect malignant cases from benign cases, especially if the size of the nodule is smaller than 4 cm.</jats:sec>
In application/xml+jats format

Archived Files and Locations

application/pdf   235.5 kB
file_rofkhui7zbhpdpbrxo4wbbg4he
www.degruyter.com (publisher)
web.archive.org (webarchive)
application/pdf   234.8 kB
file_3gh33mpnyff67erfkg6oxcjlfe
application/pdf   185.0 kB
file_hpl66qjtm5dt7lyvos4iy6thta
www.degruyter.com (publisher)
web.archive.org (webarchive)
application/pdf   235.6 kB
file_nxjxmnft7jbmnhpqcjypx72woi
www.degruyter.com (publisher)
web.archive.org (webarchive)
Read Archived PDF
Preserved and Accessible
Type  article-journal
Stage   published
Date   2019-06-03
Language   en ?
Container Metadata
Open Access Publication
In DOAJ
In Keepers Registry
ISSN-L:  1868-5021
Work Entity
access all versions, variants, and formats of this works (eg, pre-prints)
Catalog Record
Revision: 857184d0-1f84-42d0-bae7-2b46e337cae1
API URL: JSON