Factors Affecting the Segmentation of the Heart Ventricles in Short Axis Cardiac Perfusion MRI Images release_4vrcjvbndnec5llxyagccxjsty

by Doaa Mousa, Nourhan Zayed, Inas A. Yassine

Published in INTERNATIONAL JOURNAL OF COMPUTERS & TECHNOLOGY by CIRWOLRD.

2016   Volume 15, Issue 11, p7218-7226

Abstract

Cardiovascular diseases (CVDs) cause 31% of the death rate globally. Automatic accurate segmentation is needed for CVDs early detection. In this paper, we study the effect of the registration and initialization of the level set segmentation on the performance of extracting the heart ventricles for the short axis cardiac perfusion MRI images, as a result, we propose a modified workflow to automatically segment the ventricles by mitigating the levelset initial contour extraction in order to improve the segmentation results accuracy. In the registration experiments, the translational transformation was studied based on both the spatial and frequency domain. The frequency domain based registration is mainly established based on the phase correlation methodology. As for the segmentation experiments, the level set initialization was done through extracting the ventricles' real shape from each slice. Though, the final contour of any frame will be used as the initial contour for the next frame. The second initialization strategy was based on defining the initial contour for each frame using the polar representation of the image. Two short axis view datasets of cardiac magnetic resonance (CMR) perfusion imaging were used in testing the proposed methods. Dice coefficient, sensitivity, specificity and Hausdorff distance have been used to evaluate and validate the segmentation results. The system workflow consists of five main modules: preprocessing, localization, initial contour extraction, registration, and segmentation. The segmentation accuracy for left and right ventricles improved from 72% to 77% and from 70% to 81% using the spatial domain based registration algorithm. The polar-based initialization strategy improves the segmentation accuracy from 77% to 81% and from 81% to 82% for the left and right ventricles respectively.
In application/xml+jats format

Archived Files and Locations

application/pdf   544.0 kB
file_6srwvyqsefh3jdk4lppdnqqagi
proceedings.cmbes.ca (web)
web.archive.org (webarchive)
application/pdf   900.5 kB
file_5gctzpeepfho7e6rtoknnii25i
cirworld.com (web)
web.archive.org (webarchive)
Read Archived PDF
Preserved and Accessible
Type  article-journal
Stage   published
Date   2016-10-20
Journal Metadata
Not in DOAJ
Not in Keepers Registry
ISSN-L:  2277-3061
Work Entity
access all versions, variants, and formats of this works (eg, pre-prints)
Catalog Record
Revision: 41565bba-14fe-4651-865e-e8ddd58ade80
API URL: JSON